James, LP, Roberts, LA, Haff, GG, Kelly, VG, and Beckman, EM. Validity and reliability of a portable isometric mid-thigh clean pull. J Strength Cond Res 31(5): 1378–1386, 2017—This study investigated the test-retest reliability and criterion validity of force-time curve variables collected through a portable isometric mid-thigh clean pull (IMTP) device equipped with a single-axial load cell. Fifteen males with ≥6 months of resistance training experience attended two testing sessions. In each session, participants performed an IMTP in 2 separate conditions in a randomized counterbalanced manner. The criterion condition consisted of a closed-chain IMTP configured with a force plate (IMTPf), whereas the experimental test was undertaken using a portable IMTP with data acquired through a single-axial load cell (IMTPl). A very high reliability (coefficient of variation [CV] = 3.10, 90% confidence interval [CI]: 2.4–4.6%; intraclass correlation coefficient [ICC] = 0.96, 90% CI: 0.90–0.98) and acceptable validity (CV = 9.2, 90% CI: 7–14%; ICC = 0.88, 90% CI: 0.71–0.95) were found in the experimental condition for the measure of peak force. However, significant differences were present between the IMTPf and IMTPl (p < 0.0001). Alternate force-time curve variables did not reach acceptable levels of validity or reliability in the experimental condition. The IMTPl is a valid and highly reliable method for assessing peak force. This provides evidence supporting the use of an IMTPl as a cost-effective and portable alternative for those who wish to assess maximal force production in a similar fashion to a traditional IMTP. However, practitioners should be aware that these are slightly different tests.
Purpose: To determine whether the maximal strength, impulse, and power characteristics of competitive mixed-martial-arts (MMA) athletes differ according to competition level.Methods: Twenty-nine male semiprofessional and amateur MMA competitors were stratified into either higher-level (HL) or lower-level (LL) performers on the basis of competition grade and success. The 1-repetition-maximum (1RM) squat was used to assess lower-body dynamic strength, and a spectrum of impulse, power, force, and velocity variables were evaluated during an incremental-load jump squat. In addition, participants performed an isometric midthigh pull (IMTP) and 1RM bench press to determine whole-body isometric force and upper-body dynamic strength capabilities, respectively. All force and power variables were expressed relative to body mass (BM).Results: The HL competitors produced significantly superior values across a multitude of measures. These included 1RM squat strength (1.84 ± 0.23 vs 1.56 ± 0.24 kg BM; P = .003), in addition to performance in the incremental-load jump squat that revealed greater peak power (P = .005–.002), force (P = .002–.004), and velocity (P = .002–.03) at each load. Higher measures of impulse (P = .01–.04) were noted in a number of conditions. Average power (P = .002–.02) and velocity (P = .01–.04) at all loads in addition to a series of rate-dependent measures were also superior in the HL group (P = .005–.02). The HL competitors’ 1RM bench-press values approached significantly greater levels (P = .056) than the LL group’s, but IMTP performance did not differ between groups.Conclusions: Maximal lower-body neuromuscular capabilities are key attributes distinguishing HL from LL MMA competitors. This information can be used to inform evidenced-based training and performance-monitoring practices.