Shannon Tse

Dr. Shannon Tse

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2025 in Global Spine Journal
Verified
Journal Article
Open access
HSHania Shahzad
Hania Shahzad
ASAziz Saade
Aziz Saade
STShannon Tse
Shannon Tse
SSSamuel Simister
Samuel Simister
AVAnthony Viola
Anthony Viola
ADAo Spine Knowledge Forum Degenerative
Ao Spine Knowledge Forum Degenerative
Study Design: A narrative review of the current literature on the application of Computer-Assisted Navigation (CAN) in cervical spine surgeries. Objective: To analyze the perioperative integration, types of CAN systems, technical considerations, and clinical applications of CAN in cervical spine surgeries, as well as to assess the associated complications and potential strategies to minimize these risks. Methods: A comprehensive review of published studies between 2015 and 2024 was conducted to evaluate the usage, benefits, and challenges of CAN in cervical spine surgeries. The review covered perioperative integration, system types, complications, and emerging technologies, including augmented reality (AR) and robotics. Results: The use of CAN in cervical spine surgeries provides improved accuracy in screw placement and reduced neurovascular complications. However, the review identified several limitations, such as a steep learning curve, cost considerations, and potential inaccuracies related to cervical spine mobility. Conclusions: CAN offers significant benefits in cervical spine surgeries, including enhanced precision and reduced complications. Despite the current limitations, advancements in AR and robotics hold promise for improving the safety and effectiveness of CAN in cervical procedures. The future focus should be on overcoming the existing challenges to increase the adoption of CAN in cervical spine surgeries.

12 March 2025 in Bone & Joint Open
Verified
Journal Article
Open access
PDF file
KLKartik Logishetty
Kartik Logishetty
JVJeroen C. F. Verhaegen
Jeroen C. F. Verhaegen
STShannon Tse
Shannon Tse
TMTim Maheswaran
Tim Maheswaran
MFMax Fornasiero
Max Fornasiero
JWJohan D. Witt
Johan D. Witt
Aims: The effectiveness of total hip arthroplasty (THA) for patients with no or minimal radiological signs of osteoarthritis (OA) is unclear. In this study, we aimed to: 1) assess the outcome of such patients; 2) identify patient comorbidities and CT or MRI findings which predicted outcome; and 3) compare their outcome to the expected outcome of THA for hip OA.Methods: Adult patients undergoing THA for hip pain, with no or minimal radiological features of OA (Tönnis grading scale ≤ 1), were identified from a consecutive series of 1,925 THAs. Exclusion criteria were: inflammatory arthritis; osteonecrosis of the femoral head; prior trauma or infection; and patients without minimum one-year follow-up and patient-reported outcome measures (PROMs). The primary outcome measure was the Oxford Hip Score (OHS). Secondary outcome measures were EuroQol-visual analogue scale (EQ-VAS), University of California and Los Angeles (UCLA) scale, and patient satisfaction on a validated three-point ‘better’, ‘same’, or ‘worse’ scale.Results: A total of 107 patients with a median age of 41 years (IQR 18 to 73) were included, with mean follow-up of 6.0 years (SD 3.1). All patients underwent a diagnostic hip injection as a decision aid. Median postoperative OHS was 34 (IQR 28 to 42), with 36 patients (33%) achieving a patient-acceptable symptom state (OHS ≥ 42), lower than THA patients in international registries (40 to 43 points). Secondary outcomes were UCLA of 6 (4 to 8) and EQ-VAS of 73 (51 to 80); 91/102 patients (89%) felt ‘better’ and would ‘undergo surgery again'. Patients with chronic pain syndrome or hypermobility had lower OHS than patients without comorbidities (-6 points, p < 0.006). Overall, 84 patients had a CT and 34 patients an MRI. Patients with subchondral cysts (OHS 42 (37 to 45) vs 35 (26 to 36); p = 0.014) or joint space narrowing on CT (OHS 42 (IQR 37 to 44) vs 35 (26 to 36); p = 0.022) had higher function.Conclusion: Despite high satisfaction levels, patients undergoing THA with minimal or no radiological OA had lower postoperative function than typical THA patients. We recommend obtaining low-dose CT imaging and a diagnostic hip injection to aid decision-making.Cite this article: Bone Jt Open 2025;6(3):328–335.

1 February 2025 in The Bone & Joint Journal
Verified
Journal Article
Closed access
PDF file
STShannon Tse
Shannon Tse
AKAn-Sofie Van de Kelft
An-Sofie Van de Kelft
SSSamuel K. Simister
Samuel K. Simister
DFDanielle A. Forster
Danielle A. Forster
MLMarcus Lee
Marcus Lee
ARAbbas Rashid
Abbas Rashid
Aims: Complex elbow fracture-dislocations often result in suboptimal outcomes and necessitate a thorough understanding of injury patterns to guide effective management and reduce adverse sequelae. The Wrightington Classification System (WCS) offers a comprehensive approach and considers both bony and soft-tissue disruption, providing clearer guidance for treatment. This is the first external study to assess the reliability of the WCS for elbow fracture-dislocations.Methods: A blinded study of patients with elbow fracture-dislocations at a single institution between December 2014 and December 2022 was conducted. Five assessors with a range of experience, including orthopaedic surgeons and radiologists, independently classified injuries using the WCS across three image methods: plain radiograph, 2D CT, and 2D and 3D CT reconstruction images, on two occasions with an eight-week interval. Interobserver and intraobserver reliability were evaluated using kappa statistics and the Landis and Koch criteria.Results: A total of 73 patients were included in the study. Interobserver reliability was moderate, with mean kappa values of 0.518 (95% CI 0.499 to 0.537), 0.557 (95% CI 0.537 to 0.577), and 0.582 (95% CI 0.562 to 0.601), for radiographs, 2D CT, and 2D and 3D CT reconstructions, respectively. Intraobserver agreement was substantial (mean kappa 0.695 (SE 0.067), 0.729 (SE 0.071), and 0.777 (SE 0.070) for radiographs, 2D CT, and 3D CT reconstructions, respectively).Conclusion: The WCS is a reliable and valuable tool for characterizing elbow fracture-dislocations and guiding surgical interventions. This study found moderate reliability in using the WCS, with higher reliability with combined 2D and 3D CT imaging. Further refinement within the WCS in differentiating between coronoid avulsions, basal, anteromedial, and/or anterolateral facet injuries may help improve reliability and reproducibility.Cite this article: Bone Joint J 2025;107-B(2):188–192.

Verified
Journal Article
Open access
PDF file
CHChristopher Holland
Christopher Holland
STShannon Tse
Shannon Tse
CBCyrus P Bateni
Cyrus P Bateni
DCDillon Chen
Dillon Chen
CLCassandra A. Lee
Cassandra A. Lee
Background: While magnetic resonance imaging (MRI) is commonly used to identify meniscal tears, intraoperative assessment typically dictates repairability. This study evaluated whether a simplified MRI-based scoring system could reliably predict meniscal repair versus meniscectomy. Methods: Patients who underwent meniscectomy or meniscal repair between 2010 and 2018 were retrospectively identified. Preoperative MRIs were independently reviewed in a blinded fashion by two radiologists and one orthopedic sports surgeon. Reviewers scored images based on four arthroscopic criteria for tear repairability, with one point awarded for each of the following criteria—(1) proximity within 4 mm of the meniscosynovial junction, (2) length > 10 mm, (3) presence of intact inner meniscal segment, and (4) >50% meniscal thickness. Tears scoring four points were considered repairable. Accuracy, sensitivity, and positive and negative predictive values were calculated against the actual procedure performed. Inter- and intraobserver reliability were evaluated using kappa statistics. The predictive performance of each individual criterion was also analyzed. Results: A total of 202 meniscal tears were included (134 meniscectomies and 68 repairs). Reviewer accuracy in predicting repairability ranged from 48% to 76%. Intraobserver reliability was moderate to substantial (κ = 0.42–0.66), whereas interobserver reliability was poor to moderate (pairwise κ = 0.07–0.43; Fleiss’ κ = 0.11). Analysis of individual MRI criteria demonstrated limited predictive value, with most criteria achieving less than 50% accuracy across reviewers. Conclusions: MRI-based prediction of meniscal repairability using arthroscopic criteria demonstrated limited accuracy and poor interobserver reliability. Overall predictive reliability remains insufficient for clinical decision-making. Further investigation, integrating advanced imaging techniques and artificial intelligence, may improve the preoperative assessment of meniscal repairability.

1 September 2025 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
WMWestin Mace
Westin Mace
ARAmritpal S. Randhawa
Amritpal S. Randhawa
STShannon Tse
Shannon Tse
CLCassandra A. Lee
Cassandra A. Lee
CBChristopher O. Bayne
Christopher O. Bayne
Mariano E. MenendezMariano E. Menendez
Mariano E. Menendez

25 February 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MFMatthew Frederickson
Matthew Frederickson
STShannon Tse
Shannon Tse
CLCassandra A. Lee
Cassandra A. Lee