Samuel K. Simister

Samuel K. Simister

Auto-generated profile, based on publicly available information

Samuel K. Simister

Department of Orthopaedic Surgery, University of California Davis, Sacramento, California, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2024 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
SSSamuel K. Simister
Samuel K. Simister
EHEric G. Huish
Eric G. Huish
ETEugene Y. Tsai
Eugene Y. Tsai
HLHai V. Le
Hai V. Le
AHAndrea Halim
Andrea Halim
ZLZachary C. Lum
Zachary C. Lum
Introduction: The introduction of generative artificial intelligence (AI) may have a profound effect on residency applications. In this study, we explore the abilities of AI-generated letters of recommendation (LORs) by evaluating the accuracy of orthopaedic surgery residency selection committee members to identify LORs written by human or AI authors. Methods: In a multicenter, single-blind trial, a total of 45 LORs (15 human, 15 ChatGPT, and 15 Google BARD) were curated. In a random fashion, seven faculty reviewers from four residency programs were asked to grade each of the 45 LORs based on the 11 characteristics outlined in the American Orthopaedic Associations standardized LOR, as well as a 1 to 10 scale on how they would rank the applicant, their desire of having the applicant in the program, and if they thought the letter was generated by a human or AI author. Analysis included descriptives, ordinal regression, and a receiver operator characteristic curve to compare accuracy based on the number of letters reviewed. Results: Faculty reviewers correctly identified 40% (42/105) of human-generated and 63% (132/210) of AI-generated letters ( P < 0.001), which did not increase over time (AUC 0.451, P = 0.102). When analyzed by perceived author, letters marked as human generated had significantly higher means for all variables ( P = 0.01). BARD did markedly better than human authors in accuracy (3.25 [1.79 to 5.92], P < 0.001), adaptability (1.29 [1.02 to 1.65], P = 0.034), and perceived commitment (1.56 [0.99 to 2.47], P < 0.055). Additional analysis controlling for reviewer background showed no differences in outcomes based on experience or familiarity with the AI programs. Conclusion: Faculty members were unsuccessful in determining the difference between human-generated and AI-generated LORs 50% of the time, which suggests that AI can generate LORs similarly to human authors. This highlights the importance for selection committees to reconsider the role and influence of LORs on residency applications.

27 November 2023 in Journal of Surgical Oncology
Verified
Journal Article
Closed access
KWKyle Walker
Kyle Walker
SSSamuel K. Simister
Samuel K. Simister
JCJanai Carr‐Ascher
Janai Carr‐Ascher
MMMichael James Monument
Michael James Monument
STSteven W. Thorpe
Steven W. Thorpe
RRR. Lor Randall
R. Lor Randall

2 February 2023 in JSES Reviews, Reports, and Techniques
Verified
Journal Article
Open access
EBEric N. Bowman
Eric N. Bowman
CCChristopher L. Camp
Christopher L. Camp
BEBrandon Erickson
Brandon Erickson
MFMichael T. Freehill
Michael T. Freehill
MSMatthew V. Smith
Matthew V. Smith
PCPeter N. Chalmers
Peter N. Chalmers
Weighted-ball velocity training programs are popular but may be associated with increased injury risk. The purpose of this study was to determine the current frequency of these programs, as well as their association with range of motion, strength, velocity, injury, and utilization in high school baseball pitchers. This was a multicenter, prospective, community-based study including high schools from the Northeastern, Southeastern, Midwestern, and Western regions of the United States. Preseason pitchers were surveyed about their use of weighted ball velocity programs and history of injury. Preseason pitchers underwent standardized physical examinations and pitch velocity was measured. During a single high school season, pitch counts and injury incidence were prospectively collected. In total, 115 pitchers were recruited, of whom 63% had participated in a weighted ball program. There were no differences in range of motion or strength between groups who used weighted balls and those who did not. Pitchers that utilized weighted ball programs demonstrated a higher average fastball velocity (114.26 vs. 106.22 km/h [71 vs. 66 mph]; P < .001) as well as peak fastball velocity (115.87 vs. 109.44 km/h [72 vs. 68 mph]; P = .001) compared to those that did not use weighted ball programs. Pitchers that utilized weighted ball programs were no more likely to be single-sport athletes (44%) than those who were multisport athletes (49%, P = .667). Within the group who had used a weighted ball program 29% (13/45) reported a history of injury and within the group who had not used a weighted ball program 25% (10/40) reported a history of injury (P = .687). As only a single injury occurred in the entire cohort, comparison of injury rates could not be completed. In this prospective study, the majority of high school pitchers reported using weighted ball programs to increase velocity, and these programs were associated with increased average and peak velocity compared to pitchers who did not use weighted ball programs. There were no significant differences in injury history between the 2 groups. Further study is necessary to understand the injury risk associated with weighted ball programs.

1 February 2025 in The Bone & Joint Journal
Verified
Journal Article
Closed access
PDF file
STShannon Tse
Shannon Tse
AKAn-Sofie Van de Kelft
An-Sofie Van de Kelft
SSSamuel K. Simister
Samuel K. Simister
DFDanielle A. Forster
Danielle A. Forster
MLMarcus Lee
Marcus Lee
ARAbbas Rashid
Abbas Rashid
Aims: Complex elbow fracture-dislocations often result in suboptimal outcomes and necessitate a thorough understanding of injury patterns to guide effective management and reduce adverse sequelae. The Wrightington Classification System (WCS) offers a comprehensive approach and considers both bony and soft-tissue disruption, providing clearer guidance for treatment. This is the first external study to assess the reliability of the WCS for elbow fracture-dislocations.Methods: A blinded study of patients with elbow fracture-dislocations at a single institution between December 2014 and December 2022 was conducted. Five assessors with a range of experience, including orthopaedic surgeons and radiologists, independently classified injuries using the WCS across three image methods: plain radiograph, 2D CT, and 2D and 3D CT reconstruction images, on two occasions with an eight-week interval. Interobserver and intraobserver reliability were evaluated using kappa statistics and the Landis and Koch criteria.Results: A total of 73 patients were included in the study. Interobserver reliability was moderate, with mean kappa values of 0.518 (95% CI 0.499 to 0.537), 0.557 (95% CI 0.537 to 0.577), and 0.582 (95% CI 0.562 to 0.601), for radiographs, 2D CT, and 2D and 3D CT reconstructions, respectively. Intraobserver agreement was substantial (mean kappa 0.695 (SE 0.067), 0.729 (SE 0.071), and 0.777 (SE 0.070) for radiographs, 2D CT, and 3D CT reconstructions, respectively).Conclusion: The WCS is a reliable and valuable tool for characterizing elbow fracture-dislocations and guiding surgical interventions. This study found moderate reliability in using the WCS, with higher reliability with combined 2D and 3D CT imaging. Further refinement within the WCS in differentiating between coronoid avulsions, basal, anteromedial, and/or anterolateral facet injuries may help improve reliability and reproducibility.Cite this article: Bone Joint J 2025;107-B(2):188–192.

23 November 2023 in Journal of Surgical Oncology
Verified
Journal Article
Closed access
JPJacob I. Priester
Jacob I. Priester
SSSamuel K. Simister
Samuel K. Simister
MSMatthew Sario
Matthew Sario
JCJustin Choi
Justin Choi
DPDagoberto Pina
Dagoberto Pina
STSteven W. Thorpe
Steven W. Thorpe

1 November 2024 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
WVWyatt Vander Voort
Wyatt Vander Voort
EOEdmond O'DOnnell
Edmond O'DOnnell
MHMax Haffner
Max Haffner
TGTanya Garcia-Nolan
Tanya Garcia-Nolan
SSSamuel K. Md Simister
Samuel K. Md Simister
ASAugustine Saiz
Augustine Saiz
OBJECTIVES: The purpose of this study was to evaluate the biomechanical stability of a modified triangular osteosynthesis construct with S1 pedicle screws compared with other described lumbopelvic fixation constructs in a U-type sacral fracture model. METHODS: U-type sacral fractures were created in validated fourth-generation spinopelvic models. Four different constructs were cyclically loaded with displacement measured in all planes: (1) bilateral L5 pedicle screws with rods attached to iliac bolts, (2) bilateral L5 and S1 pedicle screws with rods attached to iliac bolts, (3) bilateral L5 pedicle screws with rods attached to iliac bolts with a transsacral–transiliac screw, and (4) bilateral L5 and S1 pedicle screws with rods attached to iliac bolts with a transsacral–transiliac screw. RESULTS: The bilateral L5 and S1 pedicle screws with rods attached to iliac bolts with a transsacral–transiliac screw construct had significantly decreased horizontal, vertical, and angular displacement compared with all other constructs. CONCLUSIONS: From a biomechanical perspective, a modified triangular osteosynthesis construct with S1 pedicle screws improves stability in fixation of U-type sacral fractures.