Due to the lack of inertia and uncertainty in the selection of optimal Proportional Integral (PI) controller gains, the voltage and frequency variations are higher in the islanded mode of the operation of a Microgrid (MG) compared to the grid-connected mode. This study, as such, develops an optimal control strategy for the voltage and frequency regulation of Photovoltaic (PV) based MG systems operating in islanding mode using Grasshopper Optimization Algorithm (GOA). The intelligence of the GOA is utilized to optimize the PI controller parameters. This ensures an enhanced dynamic response and power quality of the studied MG system during Distributed Generators (DG) insertion and load change conditions. A droop control is also employed within the control architecture, alongside the voltage and current control loops, as a power-sharing controller. In order to validate the performance of the proposed control architecture, its effectiveness in regulating MG voltage, frequency, and power quality is compared with the precedent Artificial Intelligence (AI) based control architectures for the same control objectives. The effectiveness of the proposed GOA based parameter selection method is also validated by analyzing its performance with respect to the improved transient response and power quality of the studied MG system in comparison with that of the Particle Swarm Optimization (PSO) and Whales Optimization Algorithm (WOA) based parameter selection methods. The simulation results establish that the GOA provides a faster and better solution than PSO and WOA which resulted in a minimum voltage and frequency overshoot with minimum output current and Total Harmonic Distortion (THD).
This paper reviews the optimization strategies for the optimal simultaneous allocation of distributed generation (DG) and shunts capacitor banks (SCBs) in electrical distribution networks. These optimization strategies aim to determine the optimal size, location, and combination of DGs and SCBs to constitute a techno-economic system while satisfying the constraints and energy demand of the load. The optimization strategies explicitly reviewed include the problem formulations, optimization techniques, restrictions posed for optimization problems, decision variables, and network operating modes typically assumed while allocating the DGs and SCBs. In addition, there is an attempt to highlight the limitations of the existing literature and future research directions. This study undertakes a comprehensive review of the literature that systematically considers the simultaneous application of DGs and SCBs to advance the existing literature, which lacks such a review. Expectedly, this review will serve as a principle platform for researchers intending to explore the subject area for further improvement.
26 March 2021 in International Journal of Energy Research
The cyclical nature and high investment costs of the wind and photovoltaic renewable energy sources are the two critical issues seeking attention for the use of such systems in backup or isolated applications. This paper aims to present the experimental and economic analysis of a wind–photovoltaic-based hybrid direct current microgrid (DCMG) system for backup power and off-grid isolated power generation system for emergency purposes. The two distributed generating units comprising photovoltaic panels and wind generator were designed and developed for the experimental study. A lead-acid battery is also added as an energy storage system to enhance the system supply. The electric load of this system comprise of 42 DC light emitting diode (LED) lamps of 12 Watt each and a 25 Watt DC fan. The charge controller provides the control and protection features for the designed system. The complete system design and fabrication of this system have been undertaken at Mehran University of Engineering & Technology (MUET, Jamshoro, Pakistan). The compatibility of the designed system has been analysed by comparing the Levelized Cost of Energy (LCOE) with a conventional gasoline generator system of the same capacity. The capital, running and lifetime costs of DCMG are found to be 1.29, 0.15 and 0.29 times those of the gasoline generator, respectively. Moreover, it is found that per unit cost of gasoline generator is $0.3 (i.e., PKR 31.4) which is almost 3.4 times higher than that of the hybrid DCMG system. The performance and cost evaluation of the designed system indicate its broad potential to be adopted for commercialisation to meet backup power and off-grid power requirements. This study concludes that proposed DCMG system is a not only low cost, but also a pollution-free alternative option compared to the existing traditional small gasoline generator system.