Sungjin Cha

Mr. Sungjin Cha

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
SKSUNG MIN KO
SUNG MIN KO
SCSungjin Cha
Sungjin Cha
HKHyunjung Kim
Hyunjung Kim
PJPil-Hyun Jeon
Pil-Hyun Jeon
SJSang-Hyun Jeon
Sang-Hyun Jeon
JSJung-Woo Son
Jung-Woo Son
(1) Background: Our aim was to evaluate the diagnostic performance of combined coronary computed tomography angiography (CCTA) and dynamic CT myocardial perfusion imaging (CT-MPI) for detecting hemodynamically significant coronary artery disease (CAD) in patients with intermediate pretest probability. (2) Methods: Patients with an intermediate pretest probability of CAD were retrospectively enrolled. All patients underwent CCTA and dynamic CT-MPI using a third-generation dual-source CT scanner prior to invasive coronary angiography (ICA). Anatomically significant stenosis was defined as ≥50% luminal narrowing on both CCTA and ICA. Fractional flow reserve (FFR) was performed during ICA in selected cases. Hemodynamically significant CAD was defined per vessel as FFR ≤ 0.80, angiographic stenosis ≥70%, or having undergone revascularization. The diagnostic performance of CCTA alone and CCTA combined with CT-MPI was compared against this reference standard. (3) Results: Seventy-four patients (mean age, 66.8 ± 11.1 years; 59 men) were included. The median coronary calcium score was 508.5 Agatston units (interquartile range: 147–1173). ICA and CCTA detected anatomically significant stenoses in 137 (61.7%) and 146 (65.8%) coronary vessels, respectively, and in 62 (83.8%) and 71 (95.9%) patients, respectively. Hemodynamically significant stenosis was present in 56 patients (76%) and 99 vessels (45%). On a per-vessel basis, CCTA alone yielded a sensitivity of 96.7%, specificity of 60.3%, positive predictive value (PPV) of 64.4%, and negative predictive value (NPV) of 96.1%. Combined CCTA and CT-MPI demonstrated a sensitivity of 90.1%, specificity of 84.3%, PPV of 82.7%, and NPV of 91.1%. The area under the receiver operating characteristic curve improved from 0.787 (95% confidence interval: 0.73–0.84) for CCTA to 0.872 (95% confidence interval: 0.82–0.91) for the combined approach (p < 0.05). The median total radiation dose for both CCTA and CT-MPI was 8.05 mSv (interquartile range: 6.71–11.0). (4) Conclusions: In patients with intermediate pretest probability of CAD, combining CCTA with dynamic CT-MPI significantly enhances the diagnostic performance for identifying hemodynamically significant coronary stenosis compared to CCTA alone.

15 September 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HKHyunjung Kim
Hyunjung Kim
JKJin Woo Kim
Jin Woo Kim
SCSungjin Cha
Sungjin Cha
SKSUNG MIN KO
SUNG MIN KO
Background/Objectives: Single-pass triple-rule-out computed tomography (CT) angiography (TRO-CTA) must compromise among differing pulmonary, coronary, and aortic contrast-transit times. Wide-area detector CT (WAD-CT) and dual-source CT (DSCT) offer different coverage, temporal resolution, and dose profiles, but direct comparative evidence for a sequential single-bolus strategy is limited in selected emergency patients with overlapping concern for acute coronary syndrome, pulmonary embolism, or acute aortic syndrome. We compared territory-specific image quality and radiation dose; diagnostic accuracy was not assessed. Methods: This retrospective study included 114 adults (WAD-CT, n = 60; DSCT, n = 54). After test-bolus timing, one weight-based diagnostic bolus was used for sequential pulmonary, electrocardiography-synchronized coronary, and non-gated aortic acquisitions. Attenuation, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), blinded dual-reader quality scores, and radiation dose were compared by territory. Results: Mean overall scores across the two readers were ≥3 for every examination in all phases. WAD-CT showed higher pulmonary trunk SNR (19.5 ± 8.9 vs. 14.3 ± 3.8; p = 0.002), higher ascending aortic SNR (24.9 ± 11.4 vs. 14.2 ± 3.0; p < 0.001), lower coronary and aortic noise, and 38.1% lower total estimated dose (6.40 ± 1.72 vs. 10.34 ± 6.91 mSv; p < 0.001). DSCT showed higher right coronary attenuation (671.8 ± 186.7 vs. 466.4 ± 128.9 Hounsfield units; p < 0.001), no significant difference in right coronary SNR (p = 0.681), and less aortic-root pulsation artifact (p < 0.001). Pulmonary- and coronary-phase overall scores were comparable. Conclusions: Both protocols provided acceptable territory-level image quality from one diagnostic bolus. WAD-CT provided lower coronary and aortic noise and estimated radiation dose, whereas DSCT provided higher coronary attenuation and less aortic-root pulsation artifact. Diagnostic accuracy and performance in subsegmental pulmonary arteries and distal or small coronary branches remain unestablished.

7 November 2026 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
CSChanghee Shin
Changhee Shin
GYGayoung Yoon
Gayoung Yoon
SCSungjin Cha
Sungjin Cha
SPSeongyong Pak
Seongyong Pak
MSMax Schöbinger
Max Schöbinger
SKSUNG MIN KO
SUNG MIN KO

13 October 2026 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
COChuluunbaatar Otgonbaatar
Chuluunbaatar Otgonbaatar
HKHyunjung Kim
Hyunjung Kim
JKJin Woo Kim
Jin Woo Kim
GDGonchigsuren Dagvasumberel
Gonchigsuren Dagvasumberel
SCSungjin Cha
Sungjin Cha
JAJhii-Hyun Ahn
Jhii-Hyun Ahn
CT-based body composition analysis provides quantitative biomarkers of muscle, adipose tissue, and bone mineral density. However, whether reconstruction te

1 July 2026 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
COChuluunbaatar Otgonbaatar
Chuluunbaatar Otgonbaatar
SCSungjin Cha
Sungjin Cha
SJSang-Hyun Jeon
Sang-Hyun Jeon
SSSue Yon Shim
Sue Yon Shim
HSHackjoon Shim
Hackjoon Shim
JAJhii-Hyun Ahn
Jhii-Hyun Ahn
Background: Contrast media-related adverse events pose serious risks, not only due to allergic reactions but also for patients with renal failure, older age, heart failure, and diabetes mellitus. Various efforts have been made to maximize vascular contrast enhancement (CE) using low-concentration contrast media. This study aimed to compare quantitative and qualitative image characteristics between vendor-agnostic and vendor-specific CE boost methods in low-concentration contrast medium settings against standard-concentration contrast medium settings. Methods: This retrospective study including 160 patients compared two concentrations of iodinated contrast media—350 mg I/mL (standard-concentration group) and 270 mg I/mL (low-concentration group) who underwent contrast-enhanced abdominal computed tomography (CT). Vendor-agnostic and vendor-specific boost methods were applied to the CT images of the low-concentration group. Quantitative [image noise, CT attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), noise power spectrum, and image sharpness] and qualitative (Likert scale rating by two radiologists) measures of image quality were evaluated in abdominal vessels and liver lesions. Results: The present study included 80 patients in the standard-concentration and 80 patients in the low-concentration group, respectively. There were no significant differences in age (P=0.75), sex (P=0.99), and body mass index (P=0.98) between the two groups. Both vendor-agnostic and vendor-specific CE-boost methods significantly reduced image noise (P<0.001) and improved CT attenuation, SNR, and CNR in both vessels and liver lesions (all P<0.001) in the low-concentration group compared to the corresponding values in the standard-concentration group. The vendor-specific boost method was more effective in suppressing high-frequency noise (P<0.001), whereas the vendor-agnostic boost method yielded sharper images (0.31±0.02 vs. 0.29±0.01; P<0.001). Subjective image analysis revealed significantly higher image quality (P<0.001) for both boost methods compared with standard-concentration contrast medium groups. Conclusions: Although vendor-agnostic and vendor-specific CE-boost methods effectively enhanced image quality and CT attenuation in low-concentration contrast medium settings, subjective image analysis revealed lower ratings due to increased artificial appearance. The vendor-agnostic method provided superior image sharpness, whereas the vendor-specific method more effectively reduced structured noise and achieved higher subjective ratings for overall image quality, artificial suppression, and natural image appearance.

24 July 2026 in Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
SCSungjin Cha
Sungjin Cha
PJPil-Hyun Jeon
Pil-Hyun Jeon
DKDong-Hee Kho
Dong-Hee Kho
HCHyosung Cho
Hyosung Cho
SKSUNG MIN KO
SUNG MIN KO
Background: This prospective randomized study protocol is designed to determine whether low-concentration iodine contrast media can maintain coronary enhancement on coronary computed tomography angiography (CCTA) compared with high-concentration iodine contrast media under standardized acquisition conditions. Dynamic stress computed tomography perfusion (CTP)-derived myocardial blood flow (MBF) will be assessed as a key secondary quantitative endpoint. Exploratory diagnostic performance analyses using invasive coronary angiography (ICA) and fractional flow reserve (FFR) will be performed only in clinically indicated invasive testing subgroups. Methods: The trial plans to enroll 258 adults (age ≥ 40 years) with known or suspected coronary artery disease referred for clinically indicated cardiac computed tomography, including CCTA with planned dynamic stress CTP. Participants will be randomized 1:1 to receive low-concentration iodine contrast media (270 mg I/mL) or high-concentration iodine contrast media (350 mg I/mL). The primary endpoint is quantitative coronary enhancement on CCTA. Dynamic stress CTP-derived MBF will be evaluated as a key secondary endpoint focused on quantitative comparability. ICA/FFR-based diagnostic performance analyses will be considered prespecified exploratory analyses in participants who undergo invasive testing as part of routine clinical care. The primary endpoint will be analyzed using linear mixed-effects models with a prespecified noninferiority margin, and MBF will be analyzed using mixed-effects models without claiming formal equivalence or noninferiority. Discussion: This study protocol is expected to clarify whether low-concentration iodine contrast media can maintain CCTA coronary enhancement and support quantitative dynamic stress CTP assessment while reducing iodine exposure. Because ICA and FFR are clinically driven rather than protocol mandated, diagnostic performance analyses will be interpreted cautiously and regarded as exploratory. Trial registration: CRIS identifier: KCT0011418. Registered on January 7, 2026.