Jasmine Antoine

Dr. Jasmine Antoine


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2024 in Resuscitation Plus
Verified
Journal Article
Open access
JAJasmine Antoine
Jasmine Antoine
BDBrian Dunn
Brian Dunn
MMMia McLanders
Mia McLanders
LJLuke Jardine
Luke Jardine
HLHelen Liley
Helen Liley
Neonatal intubation is a lifesaving skill that a variety of clinicians need to establish as it can be required anywhere babies are born or hospitalised and cannot depend on the immediate availability of an experienced senior clinician. However, neonatal intubation is complex and risky, requiring technical and non-technical skill competence. Studies report that rates of successful neonatal intubation by junior clinicians are low, providing a mandate to examine the best methods to improve skill acquisition, retention, and transfer. We utilised PRISMA-ScR methodology to capture the range of training approaches in the simulation and clinical settings, and to assess the range of technical and non-technical skill outcome measures that were used in the included studies. Databases were searched from inception to August 2024 to identify studies reporting outcomes for medical practitioners-in-training, nurses, and nurse practitioners. Identified studies meeting inclusion criteria underwent data charting with study characteristics tabulated. Twenty-six studies (involving 1449 participants) were included. Training methodology was diverse and included self-directed learning, didactic education, demonstration, simulation-based training (SBT), instructor feedback, debriefing and supervised clinical practice. Most of the studies (96 %) used multiple training methods with education and SBT most frequently used. Thirteen studies reported outcomes in clinical settings, including seven that demonstrated changes in technical skills following education and SBT. Two studies that assessed transfer of skills failed to show successful transfer from simulation to a clinical setting. Two articles reported the transfer of skills between direct and video laryngoscope devices. Only one study evaluated skill retention (at 6-9 months) but did not demonstrate proficiency after initial training or at follow up. No studies described the effects of training on non-technical skills. No included studies or combination of studies seems likely to provide a high-certainty evidence-basis for optimal training methodology. Results suggested using a training bundle including education, SBT and supervision. Knowledge gaps remain, including the most effective methodology for non-technical skill training. In addition, the evidence of technical skill retention beyond the immediate training episode, and transfer to a variety of clinical environments is very limited. Given the importance of successful neonatal intubation, more research in these areas is justified.

31 May 2025 in Children
Verified
Journal Article
Open access
PDF file
JAJasmine Antoine
Jasmine Antoine
KMKirsty L McLeod
Kirsty L McLeod
LJLuke Anthony Jardine
Luke Anthony Jardine
HLHelen G. Liley
Helen G. Liley
MMMia McLanders
Mia McLanders
Background/Objectives: Neonatal intubation is a complex procedure, often associated with low first-pass success rates and a high incidence of complications. Video laryngoscopes provide several advantages, including higher success rates, especially for novice clinicians, a magnified airway view that can be shared with supervisors, and the ability to record still or video images for debriefing and education. However, video laryngoscope devices vary, raising the possibility of differences in usability. Methods: The study used mixed methodology, including observations, semi-structured interviews, think-aloud techniques, high-fidelity simulations, function tests, and questionnaires to assess usability, defined by the clinician satisfaction, efficacy, and efficiency of six video laryngoscope devices; (1) C-MAC® with Miller blade, (2) GlideScope® CoreTM with Miller blade, (3) GlideScope® CoreTM with hyperangle LoPro blade, (4) Koala® Vision Ultra with Miller blade, (5) Koala® Handheld with Miller blade, and (6) Parker Neonatal with Miller blade. Clinician satisfaction was determined by the System Usability Scale (SUS), National Aeronautics and Space Administration Task Load Index (NASA-TLX), and clinician preference. Device efficacy was determined by first-pass success, number of attempts, and overall success. Efficiency was assessed by time to successful intubation and function test completion rates. Results: Neonatal video laryngoscopes varied considerably in design, impacting usability. All devices were deemed suitable for neonatal intubation, with the Koala® Handheld, C-MAC®, and GlideScope® Core TM Miller demonstrating the highest usability. Conclusions: This simulation-based study highlights substantial variability in neonatal video laryngoscope usability, indicating the need for further research into usability in the clinical setting.