Mia McLanders

Dr. Mia McLanders

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Resuscitation
Verified
Journal Article
Open access
VCVictoria Campbell
Victoria Campbell
RCRoger Conway
Roger Conway
KCKyle Carey
Kyle Carey
KTKhoa Tran
Khoa Tran
AVAdam Visser
Adam Visser
MCMatthew Churpek
Matthew Churpek
Early warning tools have been widely implemented without evidence to guide (a) recognition and (b) response team expertise optimisation. With growing databases from MET-calls and digital hospitals, we now have access to guiding information. The Queensland Adult-Deterioration-Detection-System (Q-ADDS) is widely used and requires validation. Compare the accuracy of Q-ADDS to National Early Warning Score (NEWS), Between-the-Flags (BTF) and the electronic Cardiac Arrest Risk Triage Score (eCART)). Data from the Chicago University hospital database were used. Clinical deterioration was defined as unplanned admission to ICU or death. Currently used NEWS, BTF and eCART trigger thresholds were compared with a clinically endorsed Q-ADDS variant. Of 224,912 admissions, 11,706 (5%) experienced clinical deterioration. Q-ADDS (AUC 0.71) and NEWS (AUC 0.72) had similar predictive accuracy, BTF (AUC 0.64) had the lowest, and eCART (AUC 0.76) the highest. Early warning alert (advising ward MO review) had similar NPV (99.2-99.3%), for all the four tools however sensitivity varied (%: Q-ADDS = 47/NEWS = 49/BTF = 66/eCART = 40), as did alerting rate (% vitals sets: Q-ADDS = 1.4/NEWS = 3.5/BTF = 4.1/eCART = 3.4). MET alert (advising MET/critical-care review) had similar NPV for all the four tools (99.1-99.2%), however sensitivity varied (%: Q-ADDS = 14/NEWS = 24/BTF = 19/eCART = 29), as did MET alerting rate (%: Q-ADDS = 1.4/NEWS = 3.5/BTF = 4.1/eCART = 3.4). High-severity alert (advising advanced ward review, Q-ADDS only): NPV = 99.1%, sensitivity = 26%, alerting rate = 3.5%. The accuracy of Q-ADDS is comparable to NEWS, and higher than BTF, with eCART being the most accurate. Q-ADDS provides an additional high-severity ward alert, and generated significantly fewer MET alerts. Impacts of increased ward awareness and fewer MET alerts on actual MET call numbers and patient outcomes requires further evaluation.

1 August 2016 in Resuscitation
Verified
Journal Article
Closed access
INIzhak Nadler
Izhak Nadler
MMMia McLanders
Mia McLanders
PSPenelope Sanderson
Penelope Sanderson
HLHelen G. Liley
Helen G. Liley

1 March 2022 in Journal of Experimental Psychology: Applied
Verified
Journal Article
Closed access
PSPenelope Sanderson
Penelope Sanderson
MMMia McLanders
Mia McLanders
CSChiara Santomauro
Chiara Santomauro
JTJimmy Tran
Jimmy Tran
SFSarah Fouhy
Sarah Fouhy
EMEmma McNulty
Emma McNulty
Healthcare workers often monitor patients while moving between different locations and tasks, and away from conventional monitoring displays. Vibrotactile displays can provide patient information in vibrotactile patterns that are felt regardless of the worker's location. We examined how effectively participants could identify changes in vibrotactile representations of patient heart rate (HR) and oxygen saturation (SpO₂). In Experiment 1, participants identified changes in HR and SpO₂ with greater than 90% accuracy while using vibrotactile displays configured in either an integrated or a separated format. In Experiment 2, incidental auditory and visual cues were removed and performance was still greater than 90% for the integrated display. In Experiments 3 and 4, ongoing tasks with low or high task load were introduced; high load worsened participants' response accuracy and speed at identifying vital signs. In Experiments 5 and 6, alternative designs were tested, including a design with a seemingly more natural mapping of HR to vibrotactile stimulation. However, no design supported more accurate performance than the integrated display. Results are interpreted with respect to multiple resource theory, and constraints on conforming to design guidelines are noted. Vibrotactile displays appear to be viable and therefore potentially suitable for use in healthcare and other contexts. (PsycInfo Database Record (c) 2022 APA, all rights reserved).

31 May 2025 in Children
Verified
Journal Article
Open access
PDF file
JAJasmine Antoine
Jasmine Antoine
KMKirsty L McLeod
Kirsty L McLeod
LJLuke Anthony Jardine
Luke Anthony Jardine
HLHelen G. Liley
Helen G. Liley
MMMia McLanders
Mia McLanders
Background/Objectives: Neonatal intubation is a complex procedure, often associated with low first-pass success rates and a high incidence of complications. Video laryngoscopes provide several advantages, including higher success rates, especially for novice clinicians, a magnified airway view that can be shared with supervisors, and the ability to record still or video images for debriefing and education. However, video laryngoscope devices vary, raising the possibility of differences in usability. Methods: The study used mixed methodology, including observations, semi-structured interviews, think-aloud techniques, high-fidelity simulations, function tests, and questionnaires to assess usability, defined by the clinician satisfaction, efficacy, and efficiency of six video laryngoscope devices; (1) C-MAC® with Miller blade, (2) GlideScope® CoreTM with Miller blade, (3) GlideScope® CoreTM with hyperangle LoPro blade, (4) Koala® Vision Ultra with Miller blade, (5) Koala® Handheld with Miller blade, and (6) Parker Neonatal with Miller blade. Clinician satisfaction was determined by the System Usability Scale (SUS), National Aeronautics and Space Administration Task Load Index (NASA-TLX), and clinician preference. Device efficacy was determined by first-pass success, number of attempts, and overall success. Efficiency was assessed by time to successful intubation and function test completion rates. Results: Neonatal video laryngoscopes varied considerably in design, impacting usability. All devices were deemed suitable for neonatal intubation, with the Koala® Handheld, C-MAC®, and GlideScope® Core TM Miller demonstrating the highest usability. Conclusions: This simulation-based study highlights substantial variability in neonatal video laryngoscope usability, indicating the need for further research into usability in the clinical setting.

7 May 2024 in Research Square
Verified
Preprint
Open access
PDF file
CSChiara Santomauro
Chiara Santomauro
MMMia McLanders
Mia McLanders
CGClinton Gibbs
Clinton Gibbs
ARAndrew Rae
Andrew Rae
Introduction: The well-known ‘golden hour’ target for trauma treatment is an unachievable goal in many parts of Australia. In response to the vast population spread in Queensland, Australia, telehealth infrastructure facilitates 24/7 links between rural facilities and specialist critical care physicians who provide advice and coordinate aeromedical retrievals. The purpose of this study was to understand work-as-done for specialist critical care physicians using Queensland Health’s emergency telehealth system to support rural clinicians during acute care. Methods: Semi-structured interviews were conducted with 10 specialist critical care physicians operating under the governance of Retrieval Services Queensland to provide advice to rural clinicians through Queensland Health’s emergency telehealth system. Using an inductive approach, qualitative data were analysed in three phases: immersion; a combination of process coding and in vivo coding; and focused coding. Results: The data revealed that supporting rural teams from a distance can be simultaneously rewarding and challenging. Two categories emerged, each with the same three themes representing key challenges to providing emergency telehealth support. The first category presents these challenges, and the second category describes how telehealth technology can help to overcome, but sometimes contributes to, these challenges. Conclusions: The findings highlight that, although challenging at times, emergency telehealth support goes far beyond clinical advice; it provides an avenue to support isolated clinicians through critical, high-stress situations. The findings have several implications for telehealth technology that could reduce specialists’ mental workload and provide better access to information, thereby improving the quality of support delivered to rural teams during critical care.

1 December 2021 in Human Factors in Healthcare
Verified
Journal Article
Open access
MMMia McLanders
Mia McLanders
PSPenelope M Sanderson
Penelope M Sanderson
SMStuart D Marshall
Stuart D Marshall
RMRichard M Mausling
Richard M Mausling
HLHelen G. Liley
Helen G. Liley
Background: Neonatal resuscitation teams face unique challenges in the delivery of patient care. Our purpose was (a) to understand team challenges and then (b) to improve the work system. Methods: The user-centred design process involved multiple iterations of requirements gathering, prototype design, evaluation, and redesign. Methods included (1) field observations, (2) interviews with neonatologists (n=3) and neonatal nurses (n=4), (3) tabletop evaluations with neonatal clinicians (N=7), and (4) in-situ simulations (N=12). Results: The intervention comprised the following four prototypes: (1) a four-page resuscitation recording form; (2) a procedural shelf attachment for the resuscitation trolley that provides additional space for sterile procedures; (3) an equipment turntable that allocates equipment layout into four sections that correspond with the steps of resuscitation; and (4) an A3-size display of the neonatal resuscitation algorithm. Simulation-based testing showed a moderate-to-high usability rating of 79.2 on the SUS (system usability scale). Conclusions: A multi-method approach provided (a) novel insight into ‘work as done’ challenges and (b) an intervention designed to address challenges within the work system. This project is an example of a systematic approach to quality improvement in a complex clinical work environment. Subsequent phases will evaluate the prototypes on teamwork and clinical performance measures.