Jörg Schroeder

Dr. Jörg Schroeder


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MLMichael Lehrke
Michael Lehrke
RMRobert Werner Mertens
Robert Werner Mertens
FKFlorian Kahles
Florian Kahles
MRMarcia Viviane Rückbeil
Marcia Viviane Rückbeil
MRMatthias Rau
Matthias Rau
MLMichael Lehrke
Michael Lehrke
Aims: Recent studies have found circulating concentrations of the gastrointestinal hormone GLP-1 to be an excellent predictor of cardiovascular risk in patients with myocardial infarction. This illustrates a yet not appreciated crosstalk between the gastrointestinal and cardiovascular systems, which requires further investigation. The gut-derived hormone Peptide YY (PYY) is secreted from the same intestinal L-cells as GLP-1. Relevance of PYY in the context of cardiovascular disease has not been explored. In this study, we aimed to investigate PYY serum concentrations in patients with acute myocardial infarction and to evaluate their association with cardiovascular events. Material and Methods: PYY levels were assessed in 834 patients presenting with acute myocardial infarction (553 Non-ST-Elevation Myocardial Infarction (NSTEMI) and 281 ST-Elevation Myocardial Infarction (STEMI)) at the time of hospital admission. The composite outcomes of first occurrence of cardiovascular death, nonfatal myocardial infarction, nonfatal stroke (3-P-MACE), and all-cause mortality were assessed with a median follow-up of 338 days. Results: PYY levels were significantly associated with age and cardiovascular risk factors, including hypertension, diabetes, and kidney function in addition to biomarkers of heart failure (NT-pro BNP) and inflammation (hs-CRP). Further, PYY was significantly associated with 3-P-MACE (HR: 1.7; 95% CI: 1–2.97; p = 0.0495) and all-cause mortality (HR: 2.69; 95% CI: 1.61–4.47; p = 0.0001) by univariable Cox regression analyses, which was however lost after adjusting for multiple confounders. Conclusions: PYY levels are associated with parameters of cardiovascular risk as well as cardiovascular events and mortality in patients presenting with acute myocardial infarction. However, this significant association is lost after adjustment for further confounders.

10 April 2025 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Open access
JSJörg Schroeder
Jörg Schroeder
NMNorman Mangner
Norman Mangner
FWFelix J. Woitek
Felix J. Woitek
KMKai U. Markus
Kai U. Markus
MLMichael Lehrke
Michael Lehrke
NMNicolas M. Van Mieghem
Nicolas M. Van Mieghem
Background: Femoral large‐bore vascular access is an important and constantly increasing technique in interventional treatment. Temporary circulatory support in complex and high‐risk indicated patients (CHIP) presents a challenge in terms of postinterventional access site closure. Aim: Monitoring the safety and efficacy of the MANTA system (Teleflex Inc.), a plug‐based vascular closure device (PbVCD) in patients receiving a percutaneous microaxial flow pump (mAFP). Methods: A multicenter prospective all‐comers registry enrolled 73 consecutive patients scheduled for PbVCD after receiving mAFP for CHIP or cardiogenic shock. The primary endpoint was the occurrence of vascular complications at the mAFP access site until discharge according to the Valve Academic Research Consortium‐3 (VARC‐3) definition. Secondary endpoints included the rate of procedure‐ or device‐related bleedings, device‐failures, and the time to hemostasis. Operators rated on the use of the MANTA System and the similarity compared to ANGIOSEAL (Terumo Medical Corp.). Results: Hemostasis was achieved in all 73 patients with no need for alternative treatment other than manual compression. The primary endpoint occurred in 7 (9.6%) patients with 1 (1.4%) patient suffering from a major vascular complication and 6 (8.2%) patients developing hematoma with type 2 bleeding (minor vascular complication). There was no vessel closure or thromboembolic event. In‐hospital survival was 100%. Conclusions: The PbVCD system is a safe, efficient and easy‐to‐use vascular closure system for large‐bore vascular access in patients receiving a mAFP. Advantages and disadvantages of PbVCD and suture‐based vascular closure devices (SbVCD) systems should be individually adapted according to the patient's medical history and the anatomy of the vascular constellation.

Verified
Journal Article
Open access
PDF file
KKKinan Kneizeh
Kinan Kneizeh
AMAndrea Milzi
Andrea Milzi
FVFelix Vogt
Felix Vogt
KWKlaus Witte
Klaus Witte
NMNikolaus Marx
Nikolaus Marx
JSJörg Schroeder
Jörg Schroeder
Objectives: We aimed to evaluate the efficacy and safety of low-dose protamine in reducing access site-related complications during Transcatheter Aortic Valve Implantation (TAVI) as compared to full-dose protamine. Background: Access site-related complications represent an independent predictor of poor outcomes of TAVI. Data regarding heparin reversal with protamine and the dosage needed to prevent bleeding complications are scarce among patients undergoing TAVI. Methods: A total of 897 patients were retrospectively included in the study. Patients who underwent percutaneous coronary intervention within 4 weeks before or concomitantly with TAVI (n = 191) were given 0.5 mg protamine for each 100 units of unfractionated heparin. All other patients (n = 706) were considered as a control group and 1 mg protamine for each 100 units of heparin was administered. Results: The combined intra-hospital endpoint of death, life-threatening major bleeding, and major vascular complications were significantly more frequent in patients receiving low-dose protamine [29 (15.2%) vs. 50 (7.1%), p < 0.001]. After propensity matching (n = 130 for each group) for relevant clinical characteristics including anti-platelet therapy [19 (14.6%) vs. 6 (4.6%), p = 0.006], low-dose protamine predicted the combined endpoint (OR 3.54, 95%-CI 1.36–9.17, p = 0.009), and even in multivariable analysis, low-dose protamine continued to be a predictor of the combined endpoint in the matched model (OR 3.07, 95%-CI 1.17–8.08, p = 0.023) alongside baseline hemoglobin. Conclusions: In this propensity-matched retrospective analysis, a low-dose protamine regime is associated with a higher rate of major adverse events compared to a full-dose protamine regime following transfemoral TAVI.

Verified
Journal Article
Open access
PDF file
ADAyham Daher
Ayham Daher
TMTobias Müller
Tobias Müller
NMNikolaus Marx
Nikolaus Marx
JSJörg Schroeder
Jörg Schroeder
MAMohammad Almalla
Mohammad Almalla
Michael DreherMichael Dreher
Michael Dreher
Sleep disordered breathing (SDB) is common among patients with valvular heart disease, and successful valve surgery could reduce SDB severity. However, data about the effects of transcatheter mitral valve repair on SDB are scarce. Therefore, mitral regurgitation (MR) patients undergoing MitraClip-placement were prospectively enrolled. Before MitraClip-placement, daytime sleepiness and sleep quality were assessed using the Epworth Sleepiness Scale (ESS) and Pittsburgh Sleep Quality Index (PSQI), respectively; and all patients underwent SDB screening using five-channel respiratory polygraphy. After 3–6 months, patients had a similar reassessment including: ESS, PSQI, and respiratory polygraphy. 67 patients were included (77 ± 8years). Despite normal sleepiness scores, 41 patients (61%) had SDB with apnea-hypopnea-index (AHI) ≥ 15 h before MitraClip-placement, of whom only three patients had known SDB previously. Compared to patients without SDB, patients with SDB had similar sleepiness scores but higher NT-proBNP values at baseline (4325 vs. 1520 pg/mL, p < 0.001). At follow-up, there were significant AHI improvements among patients with SDB (p = 0.013). However, there were no significant sleepiness score changes. In conclusion, the prevalence of SDB among MitraClip candidates is very high even in those without daytime sleepiness. MR patients with SDB have higher NT-proBNP values, which may reflect a worse prognosis. MitraClip-placement may improve the underlying SDB, which could be an additional benefit of the procedure.

17 February 2023 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
CKChristian Knackstedt
Christian Knackstedt
GSGeorg Schummers
Georg Schummers
JSJörg Schroeder
Jörg Schroeder
NMNikolaus Marx
Nikolaus Marx
JLJoost Lumens
Joost Lumens
TGthe PsychEcho study group
the PsychEcho study group
The Simpson’s method is the standard technique to determine left ventricular (LV) ejection fraction (EF) on echocardiography. The large inter-observer variability of measuring LVEF is well documented but not fully understood. A graphical analysis was used to elaborate what contributes to the inter-observer difference. Forty-two cardiologists (32 male, 39 ± 7 years) evaluated the LVEF using the Simpson’s method on 15 different echocardiograms (2 and 4 chamber view (2CH/4CH)); the program did not show the result of EF to prevent a bias. End-diastolic (ED) and end-systolic (ES) frames were predefined ensuring measurement at the same time point of the cardiac cycles. After standardization of the LV contour, the differences of the individual contours compared to a reference contour were measured. Also, the spreading of lateral/medial mitral annulus contours and the apex were depicted. A significant spreading of LV-contours was seen with larger contours leading to higher EFs (p < 0.001). Experience did not influence the determination of LVEF. ED-volumes showed more spreading than ES-volumes ((3.6 mm (IQR: 2.6–4.0) vs. 3.4 mm (IQR: 2.8–3.8), p < 0.001). Also, the differences were larger for the 2CH compared to the 4CH (p < 0.001). Variability was significantly larger for lateral than septal wall (p < 0.001) as well as the anterior compared to the inferior wall (p < 0.001). There was a relevant scattering of the apex and medial/ lateral mitral annulus ring. There was a large variability of LV-volumes and LVEF as well as position of mitral valve ring and apex. There were global differences (apical 2CH or 4CH), regional aspects (LV walls) and temporal factors (ED vs. ES). Thus, multiple factors contributed to the large variability.Trial registration: The study was registered at “Netherlands Trial Register” (www.trialregister.nl; study number: NL5131).

10 September 2017 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
SLShahram Lotfi
Shahram Lotfi
MBMichael Becker
Michael Becker
AMAjay Moza
Ajay Moza
RARüdiger Autschbach
Rüdiger Autschbach
NMNikolaus Marx
Nikolaus Marx
JSJörg Schroeder
Jörg Schroeder
Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.