In this paper, a new sensor structure is designed, which consists of a metal–insulator–metal (MIM) waveguide and a circular protrusion and a rectangular triangular cavity (CPRTC). The characterization of nanoscale sensors is considered using an approximate numerical method (finite element method). The simulation results show that the sharp asymmetric resonance generated by the interaction between the discrete narrow-band mode and the continuous wideband mode is called Fano resonance. The performance of the sensor is considerably influenced by CPRTC. The sensor structure has attained a sensitivity of 3060 nm/RIU and a figure of merit (FOM) of 53.68. In addition, the application of this structure to temperature sensors is also investigated; its sensitivity is 1.493 nm/°C. The structure also has potential for other nanosensors.
Within this manuscript, we provide a novel Fano resonance-driven micro-nanosensor. Its primary structural components are a metal-insulator-metal (MIM) waveguide, a shield with three disks, and a T-shaped cavity (STDTC). The finite element approach was used to study the gadget in theory. It is found that the adjustment of the structure and the change of the dimensions are closely related to the sensitivity (S) and the quality factor (FOM). Different model structural parameters affect the Fano resonance, which in turn changes the transmission characteristics of the resonator. Through in-depth experimental analysis and selection of appropriate parameters, the sensor sensitivity finally reaches 3020 nm/RIU and the quality factor reaches 51.89. Furthermore, the installation of this microrefractive index sensor allows for the quick and sensitive measurement of glucose levels. It is a positive contribution to the field of optical devices and micro-nano sensors and meets the demand for efficient detection when applied in medical and environmental scenarios.
This paper presents a novel nanoscale refractive index sensor, which is produced by using a metal–insulator–metal (MIM) waveguide structure coupled with the circular ring with an external rectangular ring (CRERR) structure with the Fano resonance phenomenon. In this study, COMSOL software was used to model and simulate the structure, paired with an analysis of the output spectra to detail the effect of constructional factors on the output Fano curve as measured from a finite element method. After a series of studies, it was shown that an external rectangular ring is the linchpin of the unsymmetrical Fano resonance, while the circular ring’s radius strongly influences the transducer’s capability to achieve a maximum for 3180 nm/RIU sensitivity and a FOM of 54.8. The sensor is capable of achieving sensitivities of 0.495 nm/mgdL−1 and 0.6375 nm/mgdL−1 when detecting the concentration of the electrolyte sodium and potassium ions in human blood and is expected to play an important role in human health monitoring.
As a critical component of electrostatic capacitors, the polymer dielectric directly affects the performance of the capacitor. In this work, Polycarbonate (PC)/Polyvinylidene fluoride (PVDF) asymmetric bilayer polymer dielectrics were prepared, and the influence of different polymer materials’ barrier characteristics on various electrical properties of composite dielectrics was studied by changing the direction of applied electric fields. Research has found that the dielectric constant of a composite dielectric is between PVDF and PC (approximately 4.8 at 10 Hz) and is independent of the relative position of PVDF and PC in the dielectric. However, the relative position of PC and PVDF has a significant impact on the energy-storage characteristics of composite dielectrics. When PVDF comes into contact with the negative electrode, even though PC has a higher hole barrier, the composite dielectric can only withstand a maximum electric-field strength of 400 MV/m, which is much lower than the maximum electric-field strength that pure PC can withstand (520 MV/m), and it only achieves an energy-storage density of 3.7 J/cm3. When the PC comes into contact with the negative electrode, the high electron barrier of the PC effectively suppresses the injection of electrons at the electrode. It can withstand the same electric-field strength as PC (520 MV/m), achieving an energy-storage density of 5.48 J/cm3, which is 1.46 times that of pure PC and 1.64 times that of PVDF. This experiment effectively combined the advantages of PC and PVDF by utilizing the electron/hole barrier of polymer materials to obtain a fully organic dielectric with excellent energy-storage performance.
This paper introduces a refractive index sensor based on Fano resonance, utilizing a metal–insulator–metal (MIM) waveguide structure with an Anchor-like cavity. This study utilizes the finite element method (FEM) for analyzing the propagation characteristics of the structure. The evaluation concentrated on assessing how the refractive index and the structure’s geometric parameters affect its sensing characteristics. The designed structure demonstrates optimum performance, achieving a maximum sensitivity of 2440 nm/RIU and an FOM of 63. Given its high sensitivity, this nanoscale refractive index sensor is ideal for detecting hemoglobin concentrations in blood, and the sensor’s sensitivity is 0.6 nm·g/L, aiding in clinical prevention and treatment.