In this paper, vector curvature measurement is realized by periodically etching V-grooves along one side of the optical fiber on the multi-mode fibers (MMFs) part of the SMF-MMF-SMF assembled long-period fiber grating (SMS-VLPFG). Because different bending directions will cause different degrees of deformation of the V-grooves, and then restrain the beam differently, the curvature can be vector demodulated by detecting the light loss. Based on intensity demodulation, the curvature measurement sensitivities at the 0°, 90°, and 180° positions are 11.9 dB/m-1, 9.7 dB/m-1, and -6.4 dB/m-1, respectively. The curvature sensitivity based on wavelength demodulation at the 0°, 90°, and 180° positions are -18.7 nm/m-1, -12.0 nm/m-1, and 7.3 nm/m-1, respectively. The measurement range is in the 0-1.1667 m-1. The asymmetric configuration of the sensor enables vector-sensing capability. The sensor structure is relatively compact, and the total length of the structure is only 3 mm. In the wide spectral range, The resonance effect is great and is conducive to clear demodulation. The sensor has low temperature crosstalk and temperature sensitivity is only -0.02 dB/°C (32.6 nm/°C) in the range of 20-110°C. This compact sensor based on intensity and wavelength modulation offers a novel approach for vector curvature sensing.
Effective sensing of underwater flow fields provides an important role for intelligent subaquatic equipment. Inspired by the fish lateral-lines, we proposed and demonstrated a novel bionic lateral-line photonic sensor, which employed an asymmetrically structured Fabry-Perot interference (FPI) as the fundamental sensing unit, enabling hydrodynamic signatures to be decoded by spectral evolution. Experimental results showed that the sensor achieves high-sensitivity vector flow velocity detection, with a maximum average sensitivity of 327.50 nm/(m/s) in the measuring range of 0.037 ~ 0.072 m/s. This sensor also measures oscillation frequencies within the 1-10 Hz range, achieves 0.0036 Hz frequency locking accuracy (standard deviation), and maintains a 20 cm maximum detection range. The accurate response to low-frequency signals endows the sensor with the ability to identify low-speed moving targets. And the differential responses to disturbance amplitudes that the proposed sensor has the potential to recognize the motion state of underwater moving targets. This sensor offers a fiber-optic-based alternative for unconventional underwater detection technology.
6 February 2026 in IEEE Photonics Technology Letters
Miniaturized optical fiber salinity sensor attracts an inordinate amount of attention owing to the superiorities of corrosion resistance, small volume and anti-electromagnetic interference. Herein, a highly sensitive salinity sensor based on an offset splicing fiber structure is proposed and investigated. The periodically offset no-core fiber enhances the refractive modulation of the structure and excites the high-order cladding modes to participate in the interference process. It leads to the compact length and high sensing sensitivity for the proposed fiber sensor. Experimental results show that the salinity and temperature sensitivity of the sensor reaches to –35.91 nm/% and 2.26 nm/°C, respectively. Moreover, the proposed sensor achieves the simultaneous measurements of salinity and temperature, which has the salinity resolution of 0.00058 nm/% and temperature resolution of 0.014 nm/°C. Hopefully, the proposed salinity sensor can provide some operating experience and thoughts for the design of all-fiber sensing micro-structure.
This study aims to analyze the distribution characteristics of turbulence in the western Pacific tropical region and determine the correlation between turbulence and precipitation. The obtained results show that due to the combined action of large wind shear and thermal convection, the near‐surface layer is conducive to the generation of large‐scale turbulence, and the maximum Thorpe scale can reach more than 600 m. A strong mixing zone of turbulence is generated in 10–16 km, with the monthly average occurrence rate of turbulence being about 40% and the maximum value reaching 50%. There is less turbulence in lower stratosphere due to the rapidly increased atmosphere static stability. All Thorpe scales in stratosphere are less than 100 m. The response of turbulence to precipitation in the upper troposphere is strongly affected by clouds. At the altitude in the clouds, the enhancement of precipitation has a negative relationship with turbulence. The average value of and turbulence layer thickness on rainy days are both smaller than those when the precipitation weakened. At the altitude above the clouds, the enhancement of precipitation has a slight promotion effect on the turbulence, especially for the emergence of large‐scale turbulence. When the precipitation intensifies, the amount of turbulence with greater than 150 m accounts for 6.7% of the total, while the proportion is only 2.6% on less rainy days.
23 October 2025 in Journal of Lightwave Technology
In this paper, a fiber-optic bionic superficial neuromast sensor (BSNFS) for flow measurement is proposed and validated, which utilizes multi-mode fiber (MMF) as the sensing unit. By employing arc discharge, a significant structural deformation is induced within the core region of the MMF. This fabrication process not only establishes a sensing region with strong refractive index modulation (RIM), but also simultaneously forms a bionic cilium-like structure by bending the fiber at an 87° angle with respect to its primary axis. The bio-inspired cilium is capable of receiving mechanical stimuli and transducing the mechanosensory signal to the fusion point of the MMF. This transduction modifies the original light transmission characteristics within the optical path, thereby achieving the conversion process from “cilium-based mechanical perception” to “optical signal transmission”. In experiments, the proposed sensor exhibits excellent sensitivity and tunability in flow velocity measurement. By adjusting the cilium length (1.4–3.5 cm), tunable detection can be achieved within the flow velocity range of 0.046–0.140 m/s. Correspondingly, the sensitivity ranges from 351.4-3614.9 nm/(m/s). Furthermore, benefiting from the asymmetric sensing structure design, the sensor demonstrates vector detection capability.