Zhuoda Jia

Dr. Zhuoda Jia


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2025 in Processes
Verified
Journal Article
Open access
PDF file
WLWei Li
Wei Li
XWXiaojie Wei
Xiaojie Wei
DSDaxue Sun
Daxue Sun
ZJZhuoda Jia
Zhuoda Jia
ZYZhengwei Yue
Zhengwei Yue
TPTianlian Pang
Tianlian Pang
This paper addresses the challenges of inadequate trajectory tracking accuracy and limited parameter adaptability encountered by hip joints in lower-limb exoskeletons operating across multi-terrain environments. To mitigate these issues, we propose a hybrid control strategy that synergistically combines the slime mould algorithm (SMA) with fuzzy PID control, thereby improving the trajectory tracking performance in such diverse conditions. Initially, we established a dynamic model of the hip joint in the sagittal plane utilizing the Lagrange method, which elucidates the underlying motion mechanisms involved. Subsequently, we designed a fuzzy PID controller that facilitates dynamic parameter adjustment. The integration of the slime mould algorithm (SMA) allows for the optimization of both the quantization factor and the proportional factor of the fuzzy PID controller, culminating in the development of a hybrid control framework that significantly enhances parameter adaptability. Ultimately, we performed a comparative analysis of this hybrid control strategy against conventional PID, fuzzy PID, and PSO-fuzzy PID controls through MATLABR2023b/Simulink simulations as well as experimental tests across a range of multi-terrain scenarios including flat ground, inclines, and stair climbing. The results indicate that in comparison to PID, fuzzy PID, and PSO-fuzzy PID controls, our proposed strategy significantly reduced the adjustment time by 15.06% to 61.9% and minimized the maximum error by 39.44% to 72.81% across various terrains including flat ground, slope navigation, and stair climbing scenarios. Additionally, it lowered the steady-state error ranges by an impressive 50.67% to 90.75%. This enhancement markedly improved the system’s response speed, tracking accuracy, and stability, thereby offering a robust solution for the practical application of lower-limb exoskeletons.

19 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SZSiyu Zong
Siyu Zong
WLWei Li
Wei Li
DSDawen Sun
Dawen Sun
ZJZhuoda Jia
Zhuoda Jia
ZYZhengwei Yue
Zhengwei Yue
To address the precision challenges in upper-limb joint motion prediction, this study proposes a novel artificial neural network (COANN) enhanced by the Cheetah Optimization Algorithm (COA). The model integrates surface electromyography (sEMG) signals with joint angle data through multi-source information fusion, effectively resolving the local optima issue in neural network training and improving the accuracy limitations of single sEMG predictions. Experimental results demonstrate that the COANN achieves significant performance improvements: compared with RBF neural networks, it reduces the root mean square error (RMSE) by 24.32% (ΔR2 + 18.75%) with a 22.6% shorter system runtime; relative to conventional ANNs, it decreases the RMSE by 31.59% (ΔR2 + 12.15%) while reducing computational time by 35.1%; compared with CNN neural networks, it reduces the root mean square error (RMSE) by 14.9% (ΔR2 + 3.84%); and relative to conventional LSTM, it decreases the RMSE by 15.31% (ΔR2 + 4.86%). Multi-source integration enhanced elbow joint prediction accuracy by 5.7% and shoulder joint accuracy by 6.9% compared with single sEMG approaches. This methodology provides theoretical foundations for human–robot interaction systems in upper-limb rehabilitation robotics and motion-assistive devices.

3 March 2026 in Processes
Verified
Journal Article
Open access
PDF file
WLWei Li
Wei Li
YLYukun Li
Yukun Li
ZYZhengwei Yue
Zhengwei Yue
ZJZhuoda Jia
Zhuoda Jia
BYBowen Yang
Bowen Yang
TPTianlian Pang
Tianlian Pang
The rehabilitation training of patients with lower limb motor dysfunction highly relies on the precise control of biomimetic knee joint robots. Existing control strategies generally suffer from insufficient control accuracy and weak anti-interference ability, and an optimization plan that balances high precision and strong anti-interference has not yet been formed, which seriously affects the effectiveness of rehabilitation training. In order to improve the control accuracy and anti-interference ability of biomimetic knee joint robots for leg rehabilitation training of patients with lower limb movement disorders, the purpose of this study is to address the performance shortcomings of existing biomimetic knee joint robot control strategies. The goal is to propose a high-precision and strong anti-interference control strategy to provide more reliable rehabilitation support for patients with lower limb movement disorders. Therefore, this article proposes an optimization strategy based on the Spider Bee Algorithm (SWO) combined with fuzzy PID control. Based on a biomimetic knee joint robot model, this study simulates three common pathological states of knee joint ligament injury, meniscus injury, and muscle atrophy in patients, and compares the trajectory tracking and anti-interference performance of PID, fuzzy PID, and SWO fuzzy PID control strategies. The experimental results show that the SWO fuzzy PID control strategy has the best comprehensive performance: the overshoot of knee joint angle control is only 9.7%, and the peak angle error is reduced to 2.1948°; when simulating pathological conditions, the system takes the shortest time to recover stability: 1.068 s for ligament injuries and 0.929 s for meniscus injuries, with maximum response errors below 0.017°. Simulation experiments on healthy subjects showed that the system had a tracking error of ≤5° under two rehabilitation training modes, meeting clinical accuracy requirements, and had good performance in restoring stability under irregular vibration interference. The core contribution of this study is the proposal of the SWO fuzzy PID optimization control strategy, which effectively addresses the shortcomings of existing strategies and significantly improves the control accuracy and anti-interference ability of bionic knee joint robots, providing theoretical support and practical reference for the application of bionic knee joint robots.

22 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
WLWei Li
Wei Li
ZJZhuoda Jia
Zhuoda Jia
DSDawen Sun
Dawen Sun
DHDeng Han
Deng Han
ZQZhenyang Qin
Zhenyang Qin
LQLiu Qianjin
Liu Qianjin
Home indoor environments are characterized by alternating open spaces and obstacle-cluttered regions, which pose critical challenges to the autonomous navigation of home service robots. Existing hybrid path planning algorithms generally suffer from three core limitations: low global search efficiency, weak global-local planning coordination, and poor dynamic scene adaptability. To tackle these issues, this paper presents a novel hierarchical path planning framework combining an enhanced Jump Point Search (JPS) and a fuzzy-optimized Dynamic Window Approach (DWA). In the global planning layer, an adaptive Octile heuristic JPS based on local obstacle density is designed to reduce redundant node expansion and accelerate global path search, with a bounded suboptimality guarantee. To bridge global and local planning, a look-ahead distance-based dynamic waypoint selection strategy is developed to match the optimal waypoint in real time according to the robot’s motion state and environmental complexity, enabling seamless coordination between global path guidance and local trajectory generation. In the local planning layer, a fuzzy logic controller is introduced to dynamically tune the weights of the DWA trajectory evaluation function, which significantly improves the robot’s dynamic obstacle avoidance capability and motion smoothness. Comparative simulation experiments verify that the proposed method not only outperforms the conventional hybrid path planning algorithm, reducing expanded nodes by 68.09% and global planning time by 52.94%, while improving dynamic obstacle avoidance success rate by 31.43% and overall navigation efficiency by 23.95%, it also achieves better comprehensive navigation performance than the widely adopted PSO-DWA comparison algorithm. The proposed framework shows superior comprehensive performance and is well suited for the indoor autonomous navigation of home service robots.

13 October 2025 in Processes
Verified
Journal Article
Open access
PDF file
WLWei Li
Wei Li
MWMingsen Wang
Mingsen Wang
DSDaxue Sun
Daxue Sun
ZJZhuoda Jia
Zhuoda Jia
ZYZhengwei Yue
Zhengwei Yue
This study aims to enhance the accuracy of human lower limb motion intention recognition based on surface electromyography (sEMG) signals and proposes a signal denoising method based on Sequential Variational Mode Decomposition (SVMD) optimized by the Parrot Optimization (PO) algorithm and a joint motion angle prediction model combining Residual Network (ResNet) with Gated Recurrent Unit (GRU) for the two aspects of signal processing and predictive modeling, respectively. First, for the two motion conditions of level walking and stair climbing, sEMG signals from the rectus femoris, vastus lateralis, semitendinosus, and biceps femoris, as well as the motion angles of the hip and knee joints, were simultaneously collected from five healthy subjects, yielding a total of 400 gait cycle data points. The sEMG signals were denoised using the method combining PO-SVMD with wavelet thresholding. Compared with denoising methods such as Empirical Mode Decomposition, Partial Ensemble Empirical Mode Decomposition, Independent Component Analysis, and wavelet thresholding alone, the signal-to-noise ratio (SNR) of the proposed method was increased to a maximum of 23.42 dB. Then, the gait cycle information was divided into training and testing sets at a 4:1 ratio, and five models—ResNet-GRU, Transformer-LSTM, CNN-GRU, ResNet, and GRU—were trained and tested individually using the processed sEMG signals as input and the hip and knee joint movement angles as output. Finally, the root mean square error (RMSE), mean absolute error (MAE), and coefficient of determination (R2) were used as evaluation metrics for the test results. The results show that for both motion conditions, the evaluation metrics of the ResNet-GRU model in the test results are superior to those of the other four models. The optimal evaluation metrics for level walking are 2.512 ± 0.415°, 1.863 ± 0.265°, and 0.979 ± 0.007, respectively, while the optimal evaluation metrics for stair climbing are 2.475 ± 0.442°, 2.012 ± 0.336°, and 0.98 ± 0.009, respectively. The method proposed in this study achieves improvements in both signal processing and predictive modeling, providing a new method for research on lower limb motion intention recognition.