This paper addresses the challenges of inadequate trajectory tracking accuracy and limited parameter adaptability encountered by hip joints in lower-limb exoskeletons operating across multi-terrain environments. To mitigate these issues, we propose a hybrid control strategy that synergistically combines the slime mould algorithm (SMA) with fuzzy PID control, thereby improving the trajectory tracking performance in such diverse conditions. Initially, we established a dynamic model of the hip joint in the sagittal plane utilizing the Lagrange method, which elucidates the underlying motion mechanisms involved. Subsequently, we designed a fuzzy PID controller that facilitates dynamic parameter adjustment. The integration of the slime mould algorithm (SMA) allows for the optimization of both the quantization factor and the proportional factor of the fuzzy PID controller, culminating in the development of a hybrid control framework that significantly enhances parameter adaptability. Ultimately, we performed a comparative analysis of this hybrid control strategy against conventional PID, fuzzy PID, and PSO-fuzzy PID controls through MATLABR2023b/Simulink simulations as well as experimental tests across a range of multi-terrain scenarios including flat ground, inclines, and stair climbing. The results indicate that in comparison to PID, fuzzy PID, and PSO-fuzzy PID controls, our proposed strategy significantly reduced the adjustment time by 15.06% to 61.9% and minimized the maximum error by 39.44% to 72.81% across various terrains including flat ground, slope navigation, and stair climbing scenarios. Additionally, it lowered the steady-state error ranges by an impressive 50.67% to 90.75%. This enhancement markedly improved the system’s response speed, tracking accuracy, and stability, thereby offering a robust solution for the practical application of lower-limb exoskeletons.
Against the backdrop of intensifying global population aging, lower-limb exoskeleton robots serve as core devices for rehabilitation and power assistance. Their control accuracy and motion smoothness rely on precise dynamic models. However, parameter uncertainties caused by variations in human lower limbs, assembly errors, and wear pose a critical bottleneck for accurate modeling. Aiming to achieve high-precision dynamic modeling for a two-degree-of-freedom lower-limb exoskeleton, this paper proposes a parameter identification method named Tent-GA-GWO. A dynamic model incorporating joint friction and link inertia was constructed and linearized. An excitation trajectory based on Fourier series, conforming to human physiological constraints, was designed. To enhance algorithm performance, Tent chaotic mapping was employed to optimize population initialization, a nonlinear control parameter was used to balance search behavior, and genetic algorithm operators were integrated to increase population diversity. Simulation results show that, compared to the traditional GWO algorithm, Tent-GA-GWO improved convergence efficiency by 32.1% and reduced the fitness value by 0.26%, demonstrating superior identification accuracy over algorithms such as GA and LIL-GWO. Validation on a physical prototype indicated a close agreement between the computed torque based on the identified parameters and the actual output torque, confirming the method’s effectiveness and engineering feasibility. This work provides support for precise control of exoskeletons.
The aging population and the high incidence of neurological disorders have driven an increasing demand for lower-limb motor dysfunction rehabilitation. Traditional rehabilitation methods suffer from limitations such as low efficiency and a lack of personalization. Lower-limb rehabilitation exoskeleton robots have emerged as a critical solution, with human–robot intelligent fusion serving as the core theoretical framework and technological pathway for performance enhancement. From the unique perspective of human–robot intelligent fusion, this paper systematically reviews the application and recent advances of artificial intelligence in three key aspects—intention perception, intelligent control, and human–robot integration—based on a layered architecture of “fusion perception, fusion decision-making, and fusion execution”. The definition, connotations, and realization mechanisms of human–robot intelligent fusion are clarified. Furthermore, this review analyzes the fusion mechanisms, applicable scenarios, and technical characteristics of different AI technologies and summarizes the human–robot intelligent fusion modes and clinical application status of representative products such as EksoNR, MyoSuit, and AiLegs. In addition, key challenges are identified from the perspectives of fusion generalization capabilities, the trade-off between real-time performance and robustness, algorithm interpretability, and multimodal deep fusion mechanisms. This paper provides a systematic theoretical reference and technical roadmap for establishing a unified human–robot intelligent fusion framework for lower-limb rehabilitation exoskeletons.
The rehabilitation training of patients with lower limb motor dysfunction highly relies on the precise control of biomimetic knee joint robots. Existing control strategies generally suffer from insufficient control accuracy and weak anti-interference ability, and an optimization plan that balances high precision and strong anti-interference has not yet been formed, which seriously affects the effectiveness of rehabilitation training. In order to improve the control accuracy and anti-interference ability of biomimetic knee joint robots for leg rehabilitation training of patients with lower limb movement disorders, the purpose of this study is to address the performance shortcomings of existing biomimetic knee joint robot control strategies. The goal is to propose a high-precision and strong anti-interference control strategy to provide more reliable rehabilitation support for patients with lower limb movement disorders. Therefore, this article proposes an optimization strategy based on the Spider Bee Algorithm (SWO) combined with fuzzy PID control. Based on a biomimetic knee joint robot model, this study simulates three common pathological states of knee joint ligament injury, meniscus injury, and muscle atrophy in patients, and compares the trajectory tracking and anti-interference performance of PID, fuzzy PID, and SWO fuzzy PID control strategies. The experimental results show that the SWO fuzzy PID control strategy has the best comprehensive performance: the overshoot of knee joint angle control is only 9.7%, and the peak angle error is reduced to 2.1948°; when simulating pathological conditions, the system takes the shortest time to recover stability: 1.068 s for ligament injuries and 0.929 s for meniscus injuries, with maximum response errors below 0.017°. Simulation experiments on healthy subjects showed that the system had a tracking error of ≤5° under two rehabilitation training modes, meeting clinical accuracy requirements, and had good performance in restoring stability under irregular vibration interference. The core contribution of this study is the proposal of the SWO fuzzy PID optimization control strategy, which effectively addresses the shortcomings of existing strategies and significantly improves the control accuracy and anti-interference ability of bionic knee joint robots, providing theoretical support and practical reference for the application of bionic knee joint robots.