Variable Speed Hydro-Electric Plant (VS-HEP) equipped with power electronics has been increasingly introduced into the hydraulic context. This paper is targeting a VS-HEP Power Hardware-In-the-Loop (PHIL) real-time simulation system, which is dedicated to different hydraulic operation schemes tests and control laws validation. Then, a proper hydraulic model will be the key factor for building an efficient PHIL real-time simulation system. This work introduces a practical and generalised modelling hydraulic modelling approach, which is based on ‘Hill Charts’ measurements provided by industrial manufacturers. The hydraulic static model is analytically obtained by using mathematical optimization routines. In addition, the nonlinear dynamic model of the guide vane actuator is introduced in order to evaluate the effects of the induced dynamics on the electric control performances. Moreover, the reduced-scale models adapted to different laboratory conditions can be established by applying scaling laws. The suggested modelling approach enables the features of decent accuracy, light computational complexity, high flexibility and wide applications for their implementations on PHIL real-time simulations. Finally, a grid-connected energy conversion chain of bulb hydraulic turbine associated with a permanent magnet synchronous generator is chosen as an example for PHIL design and performance assessment.
An extended state observer (ESO)-based loop filter is designed for the phase-locked loop (PLL) involved in a disturbed grid-connected converter (GcC). This ESO-based design enhances the performances and robustness of the PLL, and, therefore, improves control performances of the disturbed GcCs. Besides, the ESO-based LF can be applied to PLLs with extra filters for abnormal grid conditions. The unbalanced grid is particularly taken into account for the performance analysis. A tuning approach based on the well-designed PI controller is discussed, which results in a fair comparison with conventional PI-type PLLs. The frequency domain properties are quantitatively analysed with respect to the control stability and the noises rejection. The frequency domain analysis and simulation results suggest that the performances of the generated ESO-based controllers are comparable to those of the PI control at low frequency, while have better ability to attenuate high-frequency measurement noises. The phase margin decreases slightly, but remains acceptable. Finally, experimental tests are conducted with a hybrid power hardware-in-the-loop benchmark, in which balanced/unbalanced cases are both explored. The obtained results prove the effectiveness of ESO-based PLLs when applied to the disturbed GcC.
Energy Strategy 2050 promotes photovoltaic (PV) deployment to reduce fossil fuel dependence in Switzerland. However, limited available land constrains conventional solar farms, motivating the deployment of linear PV (LPV) systems along transport corridors such as highways or railways. This paper contributes to a systematic design and modeling methodology for an LPV power plant interconnected through a medium-voltage direct current (MVDC) collection network. The main methodological contribution is the development of a modified iterative modified nodal analysis (MNA) framework tailored to LPV–MVDC systems. In long-distance feeders with high line impedance, nonlinear voltage–current coupling becomes significant. These nonlinearities cannot be accurately captured by conventional MNA assuming fixed current injections. The proposed iterative approach can more accurately capture these effects compared to conventional MNA. A case study of a 5 km railway-based LPV system is investigated to present the design and modeling methodology, including layout design, network modeling, and cable sizing. The LPV power plant reaches a peak power of 3.4 MW and requires 40 DC/DC converter stations rated at 100 kW each. Cable analysis shows that 6 mm2 copper conductors satisfy voltage drop limits at a string level, while 95 mm2 conductors maintain MVDC voltage variations within 3%. These results highlight technical feasibility of MVDC-based integration for efficient long-distance renewable energy distribution.