Julio Cesar vergara Vergara-Vazquez

Dr. Julio Cesar vergara Vergara-Vazquez

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2023 in Advances in Science and Technology Research Journal
Verified
Journal Article
Open access
QEQuirino Estrada
Quirino Estrada
Jarosław ZubrzyckiJarosław Zubrzycki
Jarosław Zubrzycki
EJELVA LILIA REYNOSO JARDON
ELVA LILIA REYNOSO JARDON
DSDariusz Szwedowicz
Dariusz Szwedowicz
ARAlejandro Rodriguez-Mendez
Alejandro Rodriguez-Mendez
JAJesús Martin Silva Aceves
Jesús Martin Silva Aceves
Nowadays, Fused Deposition Modeling (FDM) is a powerful tool for manufacturing complex components, due to its customizability, low cost, accessibility, and fast prototyping time. It is an alternative for creating thin-walled structures, as it allows for novel designs. This article focuses on the...

30 December 2020 in ECORFAN Journal-Democratic Republic of Congo
Verified
Journal Article
Open access
JAJorge Luis Aguilar-Marin
Jorge Luis Aguilar-Marin
LCLuis Cisneros Cisneros-Villalobos
Luis Cisneros Cisneros-Villalobos
JPJorge Gabriel Padilla-Cantero
Jorge Gabriel Padilla-Cantero
JVJulio Cesar vergara Vergara-Vazquez
Julio Cesar vergara Vergara-Vazquez
The growth in the demand for electricity has led to the development and application of technologies that make its means of transport more efficient. Thus, one of these options is the implementation of transmission lines in HVDC. One of important design parameters of these lines is to know their magnetic field distribution, when it is required to calculate it, there is no methodology that can be applied to HVDC transmission lines. The following article presents a methodology that allows obtaining the density of the magnetic field on the corridor of an overhead transmission line. A case study of a 500 kV bipolar line in HVDC is presented, the results obtained are compared using the commercial software Field and corona Effects (FACE), the results obtained are consistent with those obtained from the presented methodology. An analysis of the impact of the transmission line configuration on the magnetic field density is developed, defining the most efficient configuration.

23 April 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JMJorge Luis Aguilar Marin
Jorge Luis Aguilar Marin
LCLuis Cisneros Cisneros-Villalobos
Luis Cisneros Cisneros-Villalobos
JVJOSE GERARDO VERA-DIMAS
JOSE GERARDO VERA-DIMAS
JSJorge SANCHEZ Sánchez-Jaime
Jorge SANCHEZ Sánchez-Jaime
JVJulio Cesar vergara Vergara-Vazquez
Julio Cesar vergara Vergara-Vazquez
ONOrangel Ignacio Bustos Neveros
Orangel Ignacio Bustos Neveros
The increasing deployment of shared transmission corridors for High-Voltage Alternating Current (HVAC) and High-Voltage Direct Current (HVDC) systems has intensified the need to evaluate electromagnetic compatibility in hybrid overhead line configurations. This study presents an analytical methodology to estimate the electric field magnitude and magnetic flux density generated by hybrid HVAC–HVDC transmission lines under steady-state operating conditions. The electric field is determined using the Maxwell potential matrix combined with the image method, while the magnetic field is obtained from a formulation based on the Biot–Savart law. Two representative case studies were analyzed with identical electrical operating conditions but different transverse conductor arrangements to evaluate the influence of geometry on the electromagnetic environment of the corridor. The results show that variations in the spatial configuration of the conductors produce noticeable changes in the location and magnitude of the electric and magnetic field maxima across the right-of-way. These findings demonstrate that conductor geometry plays a key role in the electromagnetic behavior of hybrid corridors and should be considered in the design and assessment of HVAC–HVDC transmission systems.

1 December 2025 in Advances in Science and Technology Research Journal
Verified
Journal Article
Open access
QEQuirino Estrada
Quirino Estrada
EJELVA LILIA REYNOSO JARDON
ELVA LILIA REYNOSO JARDON
ARAlejandro Rodriguez-Mendez
Alejandro Rodriguez-Mendez
ABAztlán Bastarrachea
Aztlán Bastarrachea
JAJesús Martin Silva Aceves
Jesús Martin Silva Aceves
ECElvis Coutiño
Elvis Coutiño
Today the implementation of biomimetic elements during the design of thin-walled structures (BTWS) is relevant among engineers and designers since bionic solutions are the result of successful evolution and adaptation processes. The current article presents the design and evaluation of five BTWS...

1 May 2026
Verified
Book Chapter
Closed access
PDF file
QEQuirino Estrada
Quirino Estrada
TMTadeusz Majewski
Tadeusz Majewski
ARAlejandro Rodriguez-Mendez
Alejandro Rodriguez-Mendez
EJELVA LILIA REYNOSO JARDON
ELVA LILIA REYNOSO JARDON
JAJesús Martin Silva Aceves
Jesús Martin Silva Aceves
JVJulio Cesar vergara Vergara-Vazquez
Julio Cesar vergara Vergara-Vazquez

30 April 2021 in Journal of Scientific and Technical Applications
Verified
Journal Article
Open access
LCLuis Cisneros Cisneros-Villalobos
Luis Cisneros Cisneros-Villalobos
JVJOSE GERARDO VERA-DIMAS
JOSE GERARDO VERA-DIMAS
JAJorge Luis Aguilar-Marin
Jorge Luis Aguilar-Marin
JVJulio Cesar vergara Vergara-Vazquez
Julio Cesar vergara Vergara-Vazquez
The dynamic behaviour of a 32 MW gas-turbine generating unit, connected to the 23 kV main busbar of a substation, is analysed in this article. The study is focused on the representative faults occurring in an electrical system and allows the determination of the maximum times in with a fault must be delivered to maintain the stability of generator. A three-phase power network is modelled with the Alternative Transients Program (ATP). Simulation results are reported and analysed for typical variables of interest such as machine rotor angle, frequency, and power. According to the study results, machine stability is greatly affected by three-phase faults, as compared to the dynamic behaviour under single-phase faults. The analysis carried out is useful to improve and maintain the security of operation of the electrical grid and in aligned to the current regulations and recent reforms of the Mexican electric sector. The fact that the performed study was usually not mandatory but has been pending since the commissioning of distributed generation plants in the Central Mexican Region is emphasized.