This paper presents a novel method for identifying critical transmission lines (CTLs) in power systems subjected to cascading overload outages, leveraging the Natural Connectivity (NC) index. Unlike previous studies that employed suboptimal weights for the edges, this work introduces a new weighting strategy that enhances the effectiveness of NC in CTLs identification. The proposed Weighted Natural Connectivity-based (WNC-based) method is validated through comparisons with established methods, including the catastrophic expectation index, and the cascading failure simulation index, using IEEE test systems of 30, 39, 57, and 118 buses and the 400 kV Mexican power system. The experimental results demonstrate that the WNC-based method accurately identifies critical lines, providing a practical balance between simplicity and precision. This study challenges prior conclusions that natural connectivity is unsuitable for CTLs identification, showcasing its potential in power system applications. Furthermore, the method's applicability extends to interconnected systems, such as the integration of power transmission, gas distribution, and telecommunication networks, paving the way for future research. The WNC-based method offers a practical tool for preventing blackouts and enhancing power grid resilience, contributing significantly to the field of power system reliability and stability.

22 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
JMJorge Luis Aguilar Marin
Jorge Luis Aguilar Marin
LCLuis Cisneros Cisneros-Villalobos
Luis Cisneros Cisneros-Villalobos
JVJOSE GERARDO VERA-DIMAS
JOSE GERARDO VERA-DIMAS
JSJorge SANCHEZ Sánchez-Jaime
Jorge SANCHEZ Sánchez-Jaime
HSHugo Saldarriaga
Hugo Saldarriaga
HGHugo Herrera Gutiérrez
Hugo Herrera Gutiérrez
High-Voltage Direct Current (HVDC) systems are transforming the global energy landscape, distinguished by their efficiency, stability, and low impact on the electrical grid. One of the challenges of HVDC transmission line design is assessing the generated stray magnetic field, as it can have negative effects on human health and the environment. This study presents an analytical methodology for calculating the magnetic field density at any point along an HVDC line corridor. It considers the spatial configuration, the current per pole, and the location of the conductors. The equations allow for the calculation of the horizontal and vertical components of the field, as well as its total magnitude. A practical case study of a ±500 and ±600 kV HVDC two-pole transmission line is presented. The methodology was programmed in MATLAB® version R2024a to calculate the magnetic field density, and the results are consistent with those obtained with the established methodology. The presented methodology can be applied to monopolar and two-pole HVDC overhead transmission lines, offering speed and accuracy.

20 May 2026 in Electricity
Verified
Journal Article
Open access
PDF file
MPMarvens Jean Pierre
Marvens Jean Pierre
EHEmmanuel Hernández
Emmanuel Hernández
Oscar Alfredo Jaramillo-SalgadoOscar Alfredo Jaramillo-Salgado
Oscar Alfredo Jaramillo-Salgado
MMManuel Madrigal
Manuel Madrigal
RCReynaldo Iracheta Cortez
Reynaldo Iracheta Cortez
GRGregorio Martínez Reyes
Gregorio Martínez Reyes
This study examines the impact of increasing photovoltaic (PV) penetration on the transient stability of the IEEE 9-bus power system. Synchronous machines are modeled with standard subtransient dynamics, while PV units are represented as current-limited grid-following inverters. Transient stability is assessed through the Critical Clearing Time (CCT) and the post-fault dynamic behavior, obtained from time-domain simulations carried out in MATLAB/Simulink® R2023b. Two permanent three-phase faults are considered: a primary contingency on line 7–5 and a secondary contingency on line 9–6, introduced to assess the robustness of the observed trends across different fault locations. The results show an increase in CCT as PV generation progressively replaces the active power supplied by synchronous machines, whose inertia is therefore maintained: from 210 ms (0% PV) to 440 ms (25%)/1080 ms (40%) at bus 5, 410 ms (25%)/1130 ms (40%) and 290 ms (25%)/650 ms (40%) at buses 6 and 8, respectively, demonstrating that the penetration site is a key factor for system stability. For distributed penetration among the three buses, CCT values of 340 ms (25%) and 1020 ms (40%) highlight the significant influence of PV placement at bus 8. The fault on line 9–6 consistently yields higher CCT values across all scenarios, confirming the robustness of these trends independently of fault location. Although an overall increase in CCT was observed, higher PV penetration also led to more pronounced oscillations and operability issues after the fault. In particular, 75% of the penetration scenarios under the fault on line 9–6 do not meet the active power recovery requirements of IEEE 1547-2018 and IEEE 2800-2022, a result more severe than that observed for the fault on line 7–5. These results underscore that a higher CCT does not guarantee operational compliance, and that stability-oriented control strategies—such as grid-forming operation, fast active power support, and dynamic voltage control—remain essential. They also suggest that planning practices should favor interconnections electrically closer to the slack generator. Overall, a high PV penetration level—modifying only the operating point of synchronous machines—allows longer fault durations to be tolerated; however, appropriate siting of PV units and the adoption of advanced inverter controls could mitigate the observed oscillations and post-fault operability challenges.

23 April 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JMJorge Luis Aguilar Marin
Jorge Luis Aguilar Marin
LCLuis Cisneros Cisneros-Villalobos
Luis Cisneros Cisneros-Villalobos
JVJOSE GERARDO VERA-DIMAS
JOSE GERARDO VERA-DIMAS
JSJorge SANCHEZ Sánchez-Jaime
Jorge SANCHEZ Sánchez-Jaime
JVJulio Cesar vergara Vergara-Vazquez
Julio Cesar vergara Vergara-Vazquez
ONOrangel Ignacio Bustos Neveros
Orangel Ignacio Bustos Neveros
The increasing deployment of shared transmission corridors for High-Voltage Alternating Current (HVAC) and High-Voltage Direct Current (HVDC) systems has intensified the need to evaluate electromagnetic compatibility in hybrid overhead line configurations. This study presents an analytical methodology to estimate the electric field magnitude and magnetic flux density generated by hybrid HVAC–HVDC transmission lines under steady-state operating conditions. The electric field is determined using the Maxwell potential matrix combined with the image method, while the magnetic field is obtained from a formulation based on the Biot–Savart law. Two representative case studies were analyzed with identical electrical operating conditions but different transverse conductor arrangements to evaluate the influence of geometry on the electromagnetic environment of the corridor. The results show that variations in the spatial configuration of the conductors produce noticeable changes in the location and magnitude of the electric and magnetic field maxima across the right-of-way. These findings demonstrate that conductor geometry plays a key role in the electromagnetic behavior of hybrid corridors and should be considered in the design and assessment of HVAC–HVDC transmission systems.

15 September 2025 in Symmetry
Verified
Journal Article
Open access
PDF file
Francisco Primero PrimeroFrancisco Primero Primero
Francisco Primero Primero
Daniel Cervantes AmbrizDaniel Cervantes Ambriz
Daniel Cervantes Ambriz
Roberto AlejoRoberto Alejo
Roberto Alejo
EGEverardo Efren Granda-Gutierrez
Everardo Efren Granda-Gutierrez
JSJorge SANCHEZ Sánchez-Jaime
Jorge SANCHEZ Sánchez-Jaime
Rosa María Valdovinos-RosasRosa María Valdovinos-Rosas
Rosa María Valdovinos-Rosas
Automated violence detection in images presents a technical and scientific challenge that demands specialized methods to enhance classification systems. This study introduces an approach for automatically identifying relevant samples to improve the performance of neural network models, specifically DenseNet121, with a focus on violence classification in images. The proposed methodology begins with an initial training phase using a balanced dataset (DS1, 6000 images). Based on the model’s output scores (outN), three confidence levels are defined: Safe (outN≥0.9+σ or outN≤0.1−σ), Border (0.5−σ≤outN≤0.5+σ), and Average (0.4−σ≤outN≤0.6+σ). These levels correspond to scenarios with low, moderate, and high prediction error probabilities, respectively, where σ is an adjustable threshold. The Border subset exhibits symmetry around the decision boundary (outN=0.5), capturing maximally uncertain samples, while the Safe regions reflect functional asymmetries in high-confidence predictions. Subsequently, these thresholds are applied to a second dataset (DS2, 5600 images) to extract specialized subsets for retraining (DSSafe, DSBorder, and DSAverage). Finally, the model is evaluated using an independent test set (DStest, 4400 images), ensuring complete data isolation. The experimental results demonstrate that the confidence-based subsets offer competitive performance despite using significantly fewer samples. The Average subset achieved an F1-Score of 0.89 and a g-mean of 0.93 using only 20% of the data, making it a promising alternative for efficient training. These findings highlight that strategic sample selection based on confidence thresholds enables effective training with reduced data, offering a practical balance between performance and efficiency when symmetric uncertainty modeling is exploited.

30 December 2025
Verified
Book Chapter
Closed access
JAJorge Luis Aguilar-Marin
Jorge Luis Aguilar-Marin
LCLuis Cisneros Cisneros-Villalobos
Luis Cisneros Cisneros-Villalobos
JSJorge SANCHEZ Sánchez-Jaime
Jorge SANCHEZ Sánchez-Jaime
JVJOSE GERARDO VERA-DIMAS
JOSE GERARDO VERA-DIMAS
Questo capitolo presenta una metodologia rigorosa per la modellizzazione e il calcolo delle impedenze di sequenza [zero, positive e negative] nelle linee di trasmissione sotterranee con circuiti paralleli. Vengono descritte le parti costitutive del cavo di potenza e le principali alternative di installazione, evidenziandone l'impatto elettrico e termico. Il calcolo si basa sulle equazioni di Carson, sulla formazione della matrice di impedenza primitiva e sulla riduzione di Kron per ottenere la matrice di fase 𝑍𝑎𝑏𝑐, e la trasformazione in componenti simmetriche per ricavare 𝑍012. TViene utilizzato il metodo della distanza media geometrica [GMD], che incorpora parametri geometrici e ambientali [GMR, spaziatura dei conduttori, resistività del suolo e messa a terra della schermatura]. Il ruolo dominante del ritorno di terra e del neutro concentrico in 𝑍0 e l'uguaglianza 𝑍1 = 𝑍2 in fase di recepimento, con implicazioni per il coordinamento dei guasti e della protezione.