Jie Lou

Dr. Jie Lou


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
BLBowen Li
Bowen Li
HSHuiru Sun
Huiru Sun
JLJie Lou
Jie Lou
KSKaiqi Sun
Kaiqi Sun
ZZZhengfa Zhang
Zhengfa Zhang
YSYuanyuan Sun
Yuanyuan Sun
With the large-scale expansionary of electric vehicles (EVs), charging facilities on highway have also been developed rapidly as supporting services, providing convenient and fast charging services for electric vehicle users. Due to the limited number and capacity of charging facilities, it is difficult to meet diverse queue waiting time needs of EV users during peak charging periods. Meanwhile, considering the integration of distributed photovoltaic and distributed energy storage system (DPV-DESS) on highway, this paper aims at proposing a strategy for the highway to coordinate multiple resources and meet the diverse charging demand of EVs. In this paper, a highway integration scheme with DPV-DESS is established to maximize the EV charging simultaneity and EV users' satisfaction while achieving the efficient utilization of DPV-DESS. Firstly, based on the DPV-DESS configuration, the model of photovoltaic (PV), energy storage and EV charging parameters are built. Secondly, considering PV output characteristics and the diverse charging needs, a two-layer optimization model is put forward. In the upper layer, multi-source coordination optimization model is proposed to realize efficient utilization. In the lower layer, an orderly charging strategy is raised for EVs senseless charging. Finally, case studies have been conducted on a self-sustained DPV-DESS consisting of a modified test system with 20 charging piles. Numerical results indicate that the proposed scheme can maximize the EV users' satisfaction while minimizing the operating cost on the premise of the self-sustained highway transportation energy system operation.

21 September 2022 in Frontiers in Energy Research
Verified
Journal Article
Open access
YLYahui Li
Yahui Li
JLJie Lou
Jie Lou
KSKaiqi Sun
Kaiqi Sun
KLKe-Jun Li
Ke-Jun Li
Source-grid-load-storage has represented an interactive characteristic in the active distribution network (ADN). Moreover, power electronic devices have been widely used for source-grid-load-storage with the rapid development of power electronics technology. In this condition, the large-scale distributed source may cause voltage quality degradation, while the application of large-scale power electronics equipment may also lead to serious harmonic distortion. Power quality has become one of the most important issues in the development of ADN. In this paper, the source-grid-load-storage interactive power quality characteristic of the ADN is analyzed. Firstly, considering the source-grid-load-storage interaction in ADN, the voltage deviation and fluctuation are analyzed and the degrees are further quantified. Then, the source-load-storage harmonic models for the power electronic components are built, which is the basis for harmonic analysis. Moreover, the decoupled harmonic power flow algorithm for ADN is proposed to analyze the system harmonic distributions. Finally, considering the location and capacity of photovoltaic and energy storage, the interaction and power quality are analyzed in the IEEE 33-bus distribution system. With the access of energy storage, more than 20% of the voltage deviation and more than 6% of the voltage fluctuation caused by photovoltaics are effectively suppressed, while the harmonic distortion may be further increased.

9 January 2023 in Frontiers in Energy Research
Verified
Journal Article
Open access
QXQingshen Xu
Qingshen Xu
JLJie Lou
Jie Lou
DNDalei Ning
Dalei Ning
PLPeihao Li
Peihao Li
In addition to the traditional long-distance and bulk power transmission application, the HVDC system can bring additional benefits to the system by providing ancillary service. The high-voltage direct-current transmission (HVDC) system can regulate its power flow in a very short time and can be used to provide emergency support to rescue the disturbed system from very bad conditions. However, because traditional generators cannot meet the great power demand of the HVDC system in a short time, the fast response of the HVDC system may cause severe power-unbalance events in the power supporting system. In this paper, a combination frequency response control (CFRC) is proposed for the fast frequency response (FFR) and HVDC system coordinating under the contingency. With the proposed combination frequency response control, the most use of the frequency response capacity of the HVDC system could be made. Meanwhile, the coordination between the HVDC system and fast frequency response could prevent the frequency of the power-source-provided system from dropping to an unacceptable level. The simulation study is conducted on a highly reduced power system model of the three North American interconnections. The simulation verification shows the effectiveness and feasibility of the proposed combination frequency response control and indicates that the frequency stability for both side systems of the HVDC system could be significantly improved with the proposed combination frequency response control. In the future, the communication delay between energy storage and HVDC will be considered in the strategy to further improve the accuracy of fast frequency response.

6 February 2026 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YZYujie Zhao
Yujie Zhao
KSKaiqi Sun
Kaiqi Sun
Wei QiuWei Qiu
Wei Qiu
YGYidian Gao
Yidian Gao
KLKe-Jun Li
Ke-Jun Li
YSYuanyuan Sun
Yuanyuan Sun
High-proportional renewable energy integration and rapid installation of new type loads, such as electric vehicles (EVs), into the power system are challenging the monitoring and operation of the power system. Different from the conventional system operation requirements, high-quality and real-time power system data become essential for system operators on key power equipment monitoring, power flow dispatching, and operation optimization. However, due to equipment limitations, bandwidth, storage and other factors, power system data is usually collected at lower sampling frequencies. Therefore, super-resolution reconstruction of these data is necessary to obtain higher frequency data to meet the system operation requirements. In this paper, a super-resolution reconstruction method based on weather-aware self-attention time series generative adversarial network (WA-TGAN) is proposed. The proposed method considers the influence of weather impacts and introduces the self-attention mechanism. The developed generator can more effectively capture long distance dependencies in power system data and improve the quality of generated data, which could help the operators obtain higher resolution and more realistic data and provide high quality data samples for tasks such as new energy forecasting and power quality assessment. The super-resolution reconstruction method proposed in this paper is validated based on actual distribution system data from northern China and publicly available datasets from Austria. The experiment results are validated through indicators such as reconstruction error and timing characteristic evaluation and compared with traditional super-resolution reconstruction methods. The experiment results indicated that the proposed method has better performance compared to the traditional methods.

13 April 2026 in Frontiers in Electronics
Verified
Journal Article
Open access
PDF file
LCLei Chen
Lei Chen
JXJiapeng Xu
Jiapeng Xu
NLNing Li
Ning Li
ZTZheng Tian
Zheng Tian
NYNaifu Yan
Naifu Yan
JLJie Lou
Jie Lou
Phasor Measurement Units (PMUs) have long been central to wide-area power system monitoring. However, the growing penetration of inverter-based resources (IBRs) and emerging data-driven analytics highlight limitations of conventional phasor abstractions in capturing fast electromagnetic dynamics. This paper provides a critical review of recent PMU advancements, emphasizing the transition from phasor-based measurements toward high-fidelity point-on-wave (PoW) sensing. Unlike existing surveys, this work evaluates the state of the art across three dimensions: (i) hardware evolution toward edge-capable sensing, (ii) AI-enabled estimation and analytics for waveform-scale data, and (iii) deployment strategies in complex environments such as microgrids and data-center-rich grids. Key bottlenecks in data acquisition and processing are summarized, and representative commercial PMU solutions are compared with emerging PoW-oriented technologies from both capability and cost-implication perspectives. An illustrative field case is included to show how waveform-level processing can reveal oscillatory components that may be attenuated under conventional multi-cycle processing. The review concludes with a strategic roadmap to bridge academic AI models with practical grid applications.

19 May 2026 in Frontiers in Applied Mathematics and Statistics
Verified
Journal Article
Open access
PDF file
LCLei Chen
Lei Chen
JXJiapeng Xu
Jiapeng Xu
NLNing Li
Ning Li
ZTZheng Tian
Zheng Tian
NYNaifu Yan
Naifu Yan
JLJie Lou
Jie Lou
This study proposes a two-stage model predictive voltage control (TS-MPC) framework for distribution networks (DNs) with high penetration of renewable generation. The framework integrates traditional voltage control devices, such as on-load tap changers (OLTCs) and capacitor banks (CBs), with distributed generation (DG) active- and reactive-power control. In the upper stage, OLTC and CB operations are optimized on a slow timescale to minimize switching, whereas in the lower stage, DG outputs are dynamically adjusted on a fast timescale to address rapid voltage fluctuations. The proposed framework leverages both the advantages of model predictive control (MPC) and DG real/reactive power control to enhance voltage regulation performance. Simulation results on a modified 33-bus test system demonstrate the effectiveness of the proposed approach.