Antonio Perez Ferrer

Dr. Antonio Perez Ferrer

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2017 in The Lancet Respiratory Medicine
Verified
Journal Article
Closed access
WHWalid Habre
Walid Habre
NDNicola Disma
Nicola Disma
KVKatalin Virag
Katalin Virag
KBKarin Becke
Karin Becke
MJMartin Jöhr
Martin Jöhr
PHPierre Harlet
Pierre Harlet

1 August 2019 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
KGKlaus Görlinger
Klaus Görlinger
AFAntonio Perez Ferrer
Antonio Perez Ferrer
DDDaniel Dirkmann
Daniel Dirkmann
FSFuat H. Saner
Fuat H. Saner
MMMarc Maegele
Marc Maegele
TKTae-Yop Kim
Tae-Yop Kim
Rotational thromboelastometry (ROTEM) is a point-of-care viscoelastic method and enables to assess viscoelastic profiles of whole blood in various clinical settings. ROTEM-guided bleeding management has become an essential part of patient blood management (PBM) which is an important concept in improving patient safety. Here, ROTEM testing and hemostatic interventions should be linked by evidence-based, setting-specific algorithms adapted to the specific patient population of the hospitals and the local availability of hemostatic interventions. Accordingly, ROTEM-guided algorithms implement the concept of personalized or precision medicine in perioperative bleeding management ('theranostic' approach). ROTEM-guided PBM has been shown to be effective in reducing bleeding, transfusion requirements, complication rates, and health care costs. Accordingly, several randomized-controlled trials, meta-analyses, and health technology assessments provided evidence that using ROTEM-guided algorithms in bleeding patients resulted in improved patient's safety and outcomes including perioperative morbidity and mortality. However, the implementation of ROTEM in the PBM concept requires adequate technical and interpretation training, education and logistics, as well as interdisciplinary communication and collaboration.

4 April 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
APAngel Augusto Perez-Calatayud
Angel Augusto Perez-Calatayud
AHAxel Hofmann
Axel Hofmann
AFAntonio Perez Ferrer
Antonio Perez Ferrer
CECarla Escorza-Molina
Carla Escorza-Molina
BTBettina Torres-Pérez
Bettina Torres-Pérez
KGKlaus Görlinger
Klaus Görlinger
Transfusion of blood products in orthotopic liver transplantation (OLT) significantly increases post-transplant morbidity and mortality and is associated with reduced graft survival. Based on these results, an active effort to prevent and minimize blood transfusion is required. Patient blood management is a revolutionary approach defined as a patient-centered, systematic, evidence-based approach to improve patient outcomes by managing and preserving a patient’s own blood while promoting patient safety and empowerment. This approach is based on three pillars of treatment: (1) detecting and correcting anemia and thrombocytopenia, (2) minimizing iatrogenic blood loss, detecting, and correcting coagulopathy, and (3) harnessing and increasing anemia tolerance. This review emphasizes the importance of the three-pillar nine-field matrix of patient blood management to improve patient outcomes in liver transplant recipients.

18 November 2015 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PDF file
AFAntonio Perez Ferrer
Antonio Perez Ferrer
JVJ. Vicente-Sanchez
J. Vicente-Sanchez
CBCarceles- Baron
Carceles- Baron
PLP. Van der Linden
P. Van der Linden
DFDavid Faraoni
David Faraoni
Early clot amplitudes measured on thromboelastometry (ROTEM®) predict maximum clot firmness (MCF) in adults. In this multicentre, retrospective study, we aimed to confirm the suspected relationship between early ROTEM® variables and MCF, in children undergoing cardiac or non-cardiac surgery. 4762 ROTEM® tests (e.g. EXTEM, INTEM, FIBTEM, APTEM, and HEPTEM) performed in children undergoing cardiac or non-cardiac surgery at three University hospitals between January 2011 and June 2014 were reviewed. To assess the correlation between clot amplitudes measured after 5, 10 and 15 min and MCF, each variable was compared with the corresponding MCF by calculating Spearman's correlation coefficient. For the EXTEM® test, we observed that amplitude measured after 5 min (A5: r=0.91, P<0.001), 10 min (A10: r=0.95, P<0.001) and 15 min (A15: r=0.96, P<0.001) were strongly correlated to MCF. The same correlations were observed for INTEM® test (A5: r=0.93, P<0.001; A10: r=0.97, P<0.001; A15: r=0.97, P<0.001), and FIBTEM® test (A5: r=0.93, P<0.001; A10: r=0.94, P<0.001; A15: r=0.96, P<0.001). In addition, the amplitudes measured after five, 10 and 15 min were also strongly correlated with MCF in the APTEM® and the HEPTEM® tests. Receiver operating characteristics (ROC) analysis confirmed that A5, A10, A15 strongly predicted decreased MCF on all ROTEM® tests. This study confirmed that early values of clot amplitudes measured as soon as five, 10 or 15 min after clotting time could be used to predict maximum clot firmness in all ROTEM® tests.

30 November 2018 in Revista Española de Anestesiología y Reanimación (English Edition)
Verified
Journal Article
Closed access
JVJ.M. Calvo Vecino
J.M. Calvo Vecino
RFR. Casans Francés
R. Casans Francés
JRJavier Ripollés-Melchor
Javier Ripollés-Melchor
CZC. Marín Zaldívar
C. Marín Zaldívar
MRM. Gómez Ríos
M. Gómez Ríos
AAAlfredo Abad-Gurumeta
Alfredo Abad-Gurumeta

30 September 2011 in Journal of Pediatric Surgery
Verified
Journal Article
Closed access
YBYolanda Laporta Baez
Yolanda Laporta Baez
MRMiguel Angel Palomero Rodriguez
Miguel Angel Palomero Rodriguez
JSJesus Carlos De Vicente Sánchez
Jesus Carlos De Vicente Sánchez
PCPascual Sanabria Carretero
Pascual Sanabria Carretero
DMDaniel Al Kassam Martínez
Daniel Al Kassam Martínez
FRFernando Gilsanz Rodríguez
Fernando Gilsanz Rodríguez