Daniel Dirkmann

Daniel Dirkmann

Auto-generated profile, based on publicly available information

Daniel Dirkmann

Department of Anesthesiology and Intensive Care Medicine, University Hospital Essen, University Duisburg-Essen, Essen, Germany

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
KGKlaus Görlinger
Klaus Görlinger
AFAntonio Perez Ferrer
Antonio Perez Ferrer
DDDaniel Dirkmann
Daniel Dirkmann
FSFuat H. Saner
Fuat H. Saner
MMMarc Maegele
Marc Maegele
TKTae-Yop Kim
Tae-Yop Kim
Rotational thromboelastometry (ROTEM) is a point-of-care viscoelastic method and enables to assess viscoelastic profiles of whole blood in various clinical settings. ROTEM-guided bleeding management has become an essential part of patient blood management (PBM) which is an important concept in improving patient safety. Here, ROTEM testing and hemostatic interventions should be linked by evidence-based, setting-specific algorithms adapted to the specific patient population of the hospitals and the local availability of hemostatic interventions. Accordingly, ROTEM-guided algorithms implement the concept of personalized or precision medicine in perioperative bleeding management ('theranostic' approach). ROTEM-guided PBM has been shown to be effective in reducing bleeding, transfusion requirements, complication rates, and health care costs. Accordingly, several randomized-controlled trials, meta-analyses, and health technology assessments provided evidence that using ROTEM-guided algorithms in bleeding patients resulted in improved patient's safety and outcomes including perioperative morbidity and mortality. However, the implementation of ROTEM in the PBM concept requires adequate technical and interpretation training, education and logistics, as well as interdisciplinary communication and collaboration.

21 July 2020 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
KGKlaus Görlinger
Klaus Görlinger
DDDaniel Dirkmann
Daniel Dirkmann
AGAjay Gandhi
Ajay Gandhi
PSPaolo Simioni
Paolo Simioni
Patients with coronavirus disease 2019 (COVID-19) frequently experience a coagulopathy associated with a high incidence of thrombotic events leading to poor outcomes. Here, biomarkers of coagulation (such as D-dimer, fibrinogen, platelet count), inflammation (such as interleukin-6), and immunity (such as lymphocyte count) as well as clinical scoring systems (such as sequential organ failure assessment [SOFA], International Society on Thrombosis and Hemostasis disseminated intravascular coagulation [ISTH DIC], and sepsis-induced coagulopathy [SIC] score) can be helpful in predicting clinical course, need for hospital resources (such as intensive care unit [ICU] beds, intubation and ventilator therapy, and extracorporeal membrane oxygenation [ECMO]) and patient’s outcome in patients with COVID-19. However, therapeutic options are actually limited to unspecific supportive therapy. Whether viscoelastic testing can provide additional value in predicting clinical course, need for hospital resources and patient’s outcome or in guiding anticoagulation in COVID-19–associated coagulopathy is still incompletely understood and currently under investigation (eg, in the rotational thromboelastometry analysis and standard coagulation tests in hospitalized patients with COVID-19 [ROHOCO] study). This article summarizes what we know already about COVID-19–associated coagulopathy and—perhaps even more importantly—characterizes important knowledge gaps.

1 September 2014 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
DDDaniel Dirkmann
Daniel Dirkmann
KGKlaus Görlinger
Klaus Görlinger
JPJürgen Peters
Jürgen Peters
Making are desirable. Accordingly, we assessed ROTEM variables from extrinsically activated assays with (APTEM®) and without (EXTEM®) addition of aprotinin for their ability to rapidly identify fibrinolysis. Specifically, we tested the hypotheses that prolonged clotting time, clot formation time, low clot firmness (at 5, 10, 15, and 20 minutes, designated A5, A10, A15, and A20, respectively), low maximum clot firmness (MCF) in EXTEM assays, and differences in these variables from parallel APTEM and EXTEM assays (designated as Δvariables) predict fibrinolysis. METHODS: Data from 411 thromboelastometric measurements (obtained from 352 patients) with fibrinolysis and from 2537 measurements without fibrinolysis (obtained from 1605 patients) were assessed and analyzed using receiver operating characteristics. Data were analyzed as a pooled fibrinolysis cohort, and subanalyses were performed from sets assigned to categories of fibrinolysis related to the timing of thrombus lysis (i.e., a decrease of clot firmness to <15% of MCF within 30, 45, and 60 minutes, respectively). A lower 95% confidence limit of the area under the receiver operating characteristic curve (AUC [SE] <0.6) was considered a failure to substantially improve detection of increased fibrinolysis. AUCs were compared to identify the variable providing the best predictive association with fibrinolysis. As a secondary end point, optimum cutoff values at the point estimate corresponding to the greatest Youden index were calculated along with the respective sensitivities and specificities. RESULTS: In the pooled cohort, clot formation time (AUC: 0.652 [0.016]), α-angle (AUC: 0.675 [0.015]), A5 (AUC: 0.718 [0.013]), A10 (AUC: 0.734 [0.0.13]), A15 (AUC: 0.752 [0.013]), A20 (AUC: 0.771 [0.013]), and MCF (AUC: 0.799 [0.012]) predicted fibrinolysis. Fibrinolysis was also predicted by ΔA15 (AUC: 0.675 [0.016]), ΔA20 (AUC: 0.719 [0.015]), and ΔMCF (AUC: 0.812 [0.013]). AUCs increased in a time-related fashion. The ability to predict subsequent fibrinolysis based on thromboelastometry was higher when it occurred early rather than later during testing. However, for prediction of late fibrinolysis, only MCF (AUC: 0.655 [0.025]) appears to be potentially clinically useful. CONCLUSIONS: Low early values of clot firmness in extrinsically activated thromboelastometric assays are associated with fibrinolysis and improve its early detection. Additional assays with aprotinin fail to improve the early diagnosis of fibrinolysis compared with assays without aprotinin....

6 September 2019 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
DDDaniel Dirkmann
Daniel Dirkmann
ENElisabeth Nagy
Elisabeth Nagy
MBMartin W. Britten
Martin W. Britten
JPJürgen Peters
Jürgen Peters
Since inadequate heparin anticoagulation and insufficient reversal can result in complications during cardiopulmonary bypass (CPB) surgery, heparin anticoagulation monitoring by point-of-care (POC) activated clotting time (ACT) measurements is essential for CPB initiation, maintainance, and anticoagulant reversal. However, concerns exist regarding reproducibility of ACT assays and comparability of devices. We evaluated the agreement of ACT assays using four parallel measurements performed on two commonly used devices each (i.e., two Hemochron Signature Elite (Hemochron) and two Abbott i-STAT (i-STAT) devices, respectively). Blood samples from 30 patients undergoing cardiac surgery on CPB were assayed at specified steps (baseline, after heparin administration, after protamine administration) with four parallel measurements (two of each device type) using commercial Kaolin activated assays provided by the respective manufactures. Measurements were compared between identical and different device types using linear regression, Bland-Altman analyses, and calculation of Cohen’s kappa coefficient. Parallel i-STAT ACTs demonstrated a good linear correlation (r = 0.985). Bias, as determined by Bland-Altman analysis, was low (− 3.8 s; 95% limits of agreement (LOA): − 77.8 -70.2 s), and Cohen’s Kappa demonstrated good agreement (kappa = 0.809). Hemochron derived ACTs demonstrated worse linear correlation (r = 0.782), larger bias with considerably broader LOA (− 13.14 s; 95%LOA:-316.3–290 s), and lesser concordance between parallel assays (kappa = 0.554). Although demonstrating a fair linear correlation (r = 0.815), parallel measurements on different ACT-devices showed large bias (−20s; 95% LOA: − 290-250 s) and little concordance (kappa = 0.368). Overall, disconcordant results according to clinically predefined target values were more frequent with the Hemochron than i-STAT. Furthermore, while discrepancies in ACT between two parallel iSTAT assays showed little or no clinical relevance, deviations from parallel Hemochron assays and iSTAT versus Hemochron measurements revealed marked and sometimes clinically critical deviations. Currently used ACT point-of-care devices cannot be used interchangeably. Furthermore, our data question the reliability of the Hemochron in assessing adequacy of heparin anticoagulation monitoring for CPB.

5 April 2007 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Closed access
PDF file
DDD. Dirkmann
D. Dirkmann
AHA. A. Hanke
A. A. Hanke
KGK. Görlinger
K. Görlinger
JPJ. Peters
J. Peters

9 March 2015 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
DDDaniel Dirkmann
Daniel Dirkmann
HGHarald Groeben
Harald Groeben
HFHassan Farhan
Hassan Farhan
DSDavid L Stahl
David L Stahl
MEMatthias Eikermann
Matthias Eikermann
This multi-centre, prospective, randomized, double-blind, placebo-controlled study was designed to test the hypotheses that parecoxib improves patients’ postoperative analgesia without increasing surgical blood loss following radical open prostatectomy. 105 patients (64 ± 7 years old) were randomized to receive either parecoxib or placebo with concurrent morphine patient controlled analgesia. Cumulative opioid consumption (primary objective) and the overall benefit of analgesia score (OBAS), the modified brief pain inventory short form (m-BPI-sf), the opioid-related symptom distress scale (OR-SDS), and perioperative blood loss (secondary objectives) were assessed. In each group 48 patients received the study medication for 48 hours postoperatively. Parecoxib significantly reduced cumulative opioid consumption by 24% (43 ± 24.1 mg versus 57 ± 28 mg, mean ± SD, p=0.02), translating into improved benefit of analgesia (OBAS: 2(0/4) versus 3(1/5.25), p=0.01), pain severity (m-BPI-sf: 1(1/2) versus 2(2/3), p < 0.01) and pain interference (m-BPI-sf: 1(0/1) versus 1(1/3), p=0.001), as well as reduced opioid-related side effects (OR-SDS score: 0.3(0.075/0.51) versus 0.4(0.2/0.83), p=0.03). Blood loss was significantly higher at 24 hours following surgery in the parecoxib group (4.3 g⋅dL−1 (3.6/4.9) versus (3.2 g⋅dL−1 (2.4/4.95), p=0.02). Following major abdominal surgery, parecoxib significantly improves patients’ perceived analgesia. Parecoxib may however increase perioperative blood loss. Further trials are needed to evaluate the effects of selective cyclooxygenase-2 inhibitors on blood loss. ClinicalTrials.gov Identifier: NCT00346268