Background and Objectives: Nontuberculous mycobacteria (NTM) infections are increasing worldwide. We evaluated the annual trends of NTM isolation on acid-fast bacillus (AFB) culture, compared to that of Mycobacterium tuberculosis, and the distribution of NTM species nationwide in South Korea. Materials and Methods: The study was conducted in a diagnostic center that is a major referral laboratory for the diagnosis of tuberculosis and NTM in South Korea. All laboratory results of AFB culture from January 2014 to December 2019 were collected. All NTM identified were definitively identified to the species level. Results: A total of 345,871 tests were performed for the diagnosis of mycobacteria. The isolation rate of NTM and M. tuberculosis was 3.7% (12,969 cases) and 4.4% (15,081 cases), respectively. The annual isolation rate of NTM increased gradually from 2.7% in 2014 to 4.8% in 2019, whereas that of M. tuberculosis decreased from 6.2% to 3.3%. There were 4988 cases of NTM identified to the species level. M. avium complex (MAC) was the most common species isolated from pulmonary sites (59.8%), followed by M. gordonae (9.2%), M. abscessus (7.0%), and M. fortuitum (5.5%). Extrapulmonary NTM were identified in 29 cases (0.6%). MAC was also the most common NTM species isolated from extrapulmonary sites (65.5%), followed by M. kansasii (10.3%), M. abscessus (6.9%), and M. fortuitum (6.9%). Conclusions: The annual isolation rate of NTM has increased gradually, whereas that of M. tuberculosis has decreased. Follow-up studies of the increases in NTM identification and NTM infections in South Korea are needed.
Single-target rapid antigen tests (RATs) are commonly used to detect highly transmissible respiratory viruses (RVs), such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza viruses. The simultaneous detection of RVs presenting overlapping symptoms is vital in making appropriate decisions about treatment, isolation, and resource utilization; however, few studies have evaluated multiplex RATs for SARS-CoV-2 and other RVs. We assessed the diagnostic performance of multiplex RATs targeting both the SARS-CoV-2 and influenza A/B viruses with the GenBody Influenza/COVID-19 Ag Triple, InstaView COVID-19/Flu Ag Combo (InstaView), STANDARDTM Q COVID-19 Ag Test, and STANDARDTM Q Influenza A/B Test kits using 974 nasopharyngeal swab samples. The cycle threshold values obtained from the real-time reverse transcription polymerase chain reaction results showed higher sensitivity (72.7–100%) when the values were below, rather than above, the cut-off values. The InstaView kit exhibited significantly higher positivity rates (80.21% for SARS-CoV-2, 61.75% for influenza A, and 46.15% for influenza B) and cut-off values (25.57 for SARS-CoV-2, 21.19 for influenza A, and 22.35 for influenza B) than the other two kits, and was able to detect SARS-CoV-2 Omicron subvariants. Therefore, the InstaView kit is the best choice for routine screening for both SARS-CoV-2 and influenza A/B in local communities.
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the third highly pathogenic human coronavirus and is rapidly transmitted by infected individuals regardless of their symptoms. During the COVID-19 pandemic, owing to the dearth of skilled healthcare workers (HCWs) to collect samples for early diagnosis, self-collection emerged as a viable alternative. To evaluate the reliability of self-collection, we compared the virus detection rate using 3990 self-collected swabs and HCW-collected swabs, procured from the same individuals and collected immediately after the self-collection. The results of multiplex reverse-transcription quantitative polymerase chain reaction revealed that the viral load in the HCW-collected swabs was marginally (18.4–28.8 times) higher than that in self-collected swabs. Self-collection showed no significant difference in sensitivity and specificity from HCW-collection (κ = 0.87, McNemar’s test; p = 0.19), indicating a comparable performance. These findings suggest that self-collected swabs are acceptable substitutes for HCW-collected swabs, and that their use improved the specimen screening efficiency and reduced the risk of SARS-CoV-2 infection among HCWs during and after the COVID-19 pandemic.
1 January 2009 in Korean Journal of Clinical Microbiology
Conventional diagnostic methods (CDMs) for lower respiratory infections (LRIs) have limitations in detecting causative pathogens. This study evaluates the utility of shotgun metagenomic sequencing (SMS) as a complementary diagnostic tool using bronchoalveolar lavage (BAL) fluid. Sixteen BAL fluid samples from pneumonia patients with positive CDM results—including bacterial/fungal cultures; PCR for Mycobacterium tuberculosis or cytomegalovirus; and the BioFire® FilmArray® Pneumonia Panel (BioFire Diagnostics LLC, Salt Lake City, UT, USA)—underwent 10 Gb SMS on the Illumina NovaSeq 6000 platform (Illumina, San Diego, CA, USA). Reads were aligned to the NCBI RefSeq database; with fungal identification further supported by internal transcribed spacer (ITS) analysis. Antibiotic resistance genes (ARGs) were annotated using the Comprehensive Antibiotic Resistance Database. Microbial reads accounted for 0.00002–0.04971% per sample. SMS detected corresponding bacteria in 63% of cases, increasing to 69% when subdominant taxa were included. Fungal reads were low; however, Candida species were identified in four samples via ITS. No viral reads were detected. ARGs meeting perfect match criteria were found in two cases. This is the first real-world study comparing SMS with CDMs, including semiquantitative PCR, in BAL fluid for LRI. SMS shows promise as a supplementary diagnostic method, with further research needed to optimize its performance and cost-effectiveness.