Min Young Park

Dr. Min Young Park

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2022 in Life
Verified
Journal Article
Open access
PDF file
HLHo-Jae LIM
Ho-Jae LIM
HJHye Soo Jung
Hye Soo Jung
MPMin Young Park
Min Young Park
YBYoung-Hyun Baek
Young-Hyun Baek
BKBalaji Kannappan
Balaji Kannappan
YYYong-Jin Yang
Yong-Jin Yang
Severe acute respiratory syndrome coronavirus (SARS-CoV-2) is highly contagious and causes coronavirus disease 2019 (COVID-19). Reverse transcription quantitative polymerase chain reaction (RT-qPCR) is the most accurate and reliable molecular assay to detect active SARS-CoV-2 infection. However, a rapid increase in test subjects has created a global bottleneck in testing capacity. Given that efficient nucleic acid extraction greatly affects reliable and accurate testing results, we compared three extraction platforms: MagNA Pure 96 DNA and Viral NA Small Volume kit on MagNA Pure 96 (Roche, Basel, Switzerland), careGENETM Viral/Pathogen HiFi Nucleic Acid Isolation kit (WELLS BIO Inc., Seoul, Korea) on KingFisher Flex (Thermo Fisher Scientific, Rocklin, CA, USA), and SGRespiTM Pure kit (Seegene Inc., Seoul, Korea) on Maelstrom 9600 (Taiwan Advanced Nanotech Inc., Taoyuan, Taiwan). RNA was extracted from 245 residual respiratory specimens from the different types of samples (i.e., NPS, sputum, and saliva) using three different kits. The 95% limits of detection of median tissue culture infectious dose per milliliter (TCID50/mL) for the MagNA Pure 96, KingFisher Flex, and Maelstrom 9600 were 0.37–3.15 × 101, 0.41–3.62 × 101, and 0.33–1.98 × 101, respectively. The KingFisher Flex platform exhibited 99.2% sensitivity and 100% specificity, whereas Maelstrom 9600 exhibited 98.3–100% sensitivity and 100% specificity. Bland–Altman analysis revealed a 95.2% concordance between MagNA Pure 96 and KingFisher Flex and 95.4% concordance between MagNA Pure 96 and Maelstrom 9600, indicating that all three platforms provided statistically reliable results. This suggests that two modifying platforms, KingFisher Flex and Maelstrom 9600, are accurate and scalable extraction platforms for large-scale SARS-CoV-2 clinical detection and could help the management of COVID-19 patients.

9 December 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
HLHo-Jae LIM
Ho-Jae LIM
JLJi-Yoon Lee
Ji-Yoon Lee
YBYoung-Hyun Baek
Young-Hyun Baek
MPMin Young Park
Min Young Park
DYDong-Jae Youm
Dong-Jae Youm
YYYong-Jin Yang
Yong-Jin Yang
Single-target rapid antigen tests (RATs) are commonly used to detect highly transmissible respiratory viruses (RVs), such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza viruses. The simultaneous detection of RVs presenting overlapping symptoms is vital in making appropriate decisions about treatment, isolation, and resource utilization; however, few studies have evaluated multiplex RATs for SARS-CoV-2 and other RVs. We assessed the diagnostic performance of multiplex RATs targeting both the SARS-CoV-2 and influenza A/B viruses with the GenBody Influenza/COVID-19 Ag Triple, InstaView COVID-19/Flu Ag Combo (InstaView), STANDARDTM Q COVID-19 Ag Test, and STANDARDTM Q Influenza A/B Test kits using 974 nasopharyngeal swab samples. The cycle threshold values obtained from the real-time reverse transcription polymerase chain reaction results showed higher sensitivity (72.7–100%) when the values were below, rather than above, the cut-off values. The InstaView kit exhibited significantly higher positivity rates (80.21% for SARS-CoV-2, 61.75% for influenza A, and 46.15% for influenza B) and cut-off values (25.57 for SARS-CoV-2, 21.19 for influenza A, and 22.35 for influenza B) than the other two kits, and was able to detect SARS-CoV-2 Omicron subvariants. Therefore, the InstaView kit is the best choice for routine screening for both SARS-CoV-2 and influenza A/B in local communities.

13 June 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
HLHo-Jae LIM
Ho-Jae LIM
JPJung Eun Park
Jung Eun Park
MPMin Young Park
Min Young Park
JBJoo-Hwan Baek
Joo-Hwan Baek
SJSunkyung Jung
Sunkyung Jung
YYYong-Jin Yang
Yong-Jin Yang
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) triggers disease with nonspecific symptoms that overlap those of infections caused by other seasonal respiratory viruses (RVs), such as the influenza virus (Flu) or respiratory syncytial virus (RSV). A molecular assay for accurate and rapid detection of RV and SARS-CoV-2 is crucial to manage these infections. Here, we compared the analytical performance and clinical reliability of Allplex™ SARS-CoV-2/FluA/FluB/RSV (SC2FabR; Seegene Inc., Seoul, South Korea) kit with those of four commercially available RV detection kits. Upon testing five target viral strains (SARS-CoV-2, FluA, FluB, RSV A, and RSV B), the analytical performance of SC2FabR was similar to that of the other kits, with no significant difference (p ≥ 0.78) in z-scores. The efficiency of SC2FabR (E-value, 81–104%) enabled reliable SARS-CoV-2 and seasonal RV detection in 888 nasopharyngeal swab specimens processed using a fully automated nucleic acid extraction platform. Bland–Altman analyses revealed an agreement value of 95.4% (SD ± 1.96) for the kits, indicating statistically similar results for all five. In conclusion, SC2FabR is a rapid and accurate diagnostic tool for both SARS-CoV-2 and seasonal RV detection, allowing for high-throughput RV analysis with efficiency comparable to that of commercially available kits. This can be used to help manage respiratory infections in patients during and after the coronavirus disease 2019 pandemic.

21 September 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
HLHo-Jae LIM
Ho-Jae LIM
YBYoung-Hyun Baek
Young-Hyun Baek
MPMin Young Park
Min Young Park
JYJae-Hyun Yang
Jae-Hyun Yang
MKMin Jin Kim
Min Jin Kim
YYYong-Jin Yang
Yong-Jin Yang
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the third highly pathogenic human coronavirus and is rapidly transmitted by infected individuals regardless of their symptoms. During the COVID-19 pandemic, owing to the dearth of skilled healthcare workers (HCWs) to collect samples for early diagnosis, self-collection emerged as a viable alternative. To evaluate the reliability of self-collection, we compared the virus detection rate using 3990 self-collected swabs and HCW-collected swabs, procured from the same individuals and collected immediately after the self-collection. The results of multiplex reverse-transcription quantitative polymerase chain reaction revealed that the viral load in the HCW-collected swabs was marginally (18.4–28.8 times) higher than that in self-collected swabs. Self-collection showed no significant difference in sensitivity and specificity from HCW-collection (κ = 0.87, McNemar’s test; p = 0.19), indicating a comparable performance. These findings suggest that self-collected swabs are acceptable substitutes for HCW-collected swabs, and that their use improved the specimen screening efficiency and reduced the risk of SARS-CoV-2 infection among HCWs during and after the COVID-19 pandemic.

10 August 2022 in International Journal of Analytical Chemistry
Verified
Journal Article
Open access
PDF file
YBYoung-Hyun Baek
Young-Hyun Baek
MPMin Young Park
Min Young Park
HLHo-Jae LIM
Ho-Jae LIM
HJHye Soo Jung
Hye Soo Jung
JYJae-Hyun Yang
Jae-Hyun Yang
YYYong-Jin Yang
Yong-Jin Yang
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes coronavirus disease 2019 (COVID-19), is still rapidly spreading as of March 2022. An accurate and rapid molecular diagnosis is essential to determine the exact number of confirmed cases. Currently, the viral transport medium (VTM) required for testing is in short supply due to a sharp increase in the laboratory tests performed, and alternative VTMs are needed to alleviate the shortage. Guanidine thiocyanate-based media reportedly inactivate SARS-CoV-2 and are compatible with quantitative reverse transcription polymerase chain reaction (RT-qPCR) assays, but the compatibility and the viral detection capacity have not been fully validated. To evaluate the guanidine thiocyanate-based Gene Transport Medium (GeneTM) as an alternative VTM, we prepared 39 SARS-CoV-2-positive and 7 SARS-CoV-2-negative samples in GeneTM, eNAT, and phosphate-buffered saline (PBS). The cycle threshold (Ct) values of three SARS-CoV-2 targets (the S, RdRP, and N genes) were analyzed using RT-qPCR testing. The comparison of Ct values from the positive samples showed a high correlation (R2=0.950.96) between GeneTM and eNAT, indicating a comparable viral detection capacity. The delta Ct values of the SARS-CoV-2 genes in each transport medium were maintained for 14 days at cold (4°C) or room (25°C) temperatures, suggesting viral samples were stably preserved in the transport media for 14days. Together, GeneTM is a potential alternative VTM with comparable RT-qPCR performance and stability to those of standard media.

29 August 2024 in Journal of Fungi
Verified
Journal Article
Open access
PDF file
HLHo-Jae LIM
Ho-Jae LIM
SASeojin Ahn
Seojin Ahn
JNJee Hyun No
Jee Hyun No
MPMin Young Park
Min Young Park
MKMin Jin Kim
Min Jin Kim
YYYong-Jin Yang
Yong-Jin Yang
Infectious diseases caused by fungal sources are of great interest owing to their increasing prevalence. Invasive fungal infections, including invasive pulmonary aspergillosis caused by Aspergillus fumigatus, and Pneumocystis pneumonia caused by Pneumocystis jirovecii, are significant causes of morbidity and mortality among immunocompromised patients. The accurate and timely detection of these pathogens in this high-risk population is crucial for effective patient management. We developed a multiplex real-time polymerase chain reaction (PCR) assay, RF2 mRT-PCR, specifically designed to detect two respiratory fungi, P. jirovecii and A. fumigatus, and evaluated its performance in specimens of patients with lower respiratory tract infection. The performance was evaluated using 731 clinical samples, 55 reference species, and one synthetic DNA. The reproducibility test yielded a probit curve with a lower limit of detection of 19.82 copies/reaction for P. jirovecii and 64.20 copies/reaction for A. fumigatus. The RF2 mRT-PCR assay did not cross-react with non-A. fumigatus Aspergillus species or other common bacterial and viral species, and showed 100% in vitro sensitivity and specificity with reference assays. Additionally, it simultaneously detected A. fumigatus and P. jirovecii in co-infected samples. Therefore, the RF2 mRT-PCR assay is an efficient and reliable tool for in vitro diagnosis of A. fumigatus and P. jirovecii pulmonary infections.