Sensitivity and performance of homodyne radar are notably improved if the phase noise terms of transmit and receive signals are correlated and cancelled out by the receiver. However, in a bistatic setup with separate oscillators, this correlation is inherently not given. To achieve a good carrier phase and phase noise coherency it is required to transmit a radio frequency (RF) reference e.g. by using high-quality RF cables, optical fibers or wireless point-to-point links. All these options are complex, costly and prone to distortions and signal delay variations. Sharing a clock signal is also barely helpful, since even small distortions of this reference are converted to notable uncorrelated phase noise in the radar signal synthesizers. In this paper, a novel full-duplex system concept and signal processing scheme is presented that solves the above-mentioned problems completely. This concept allows for coherent measurements within a bistatic radar setup, even if the two radar stations are only loosely coupled employing a simple clock-rate adjustment. By theory and experimental results with bistatic frequency modulated continuous wave (FMCW) radar it is shown that our concept allows for bistatic measurements with the same sensitivity and performance that is usually know from homodyne radar systems. To the authors' best knowledge, this is the first time that phase noise coherent measurements in a bistatic multiple-input multiple-output (MIMO) radar setup are shown. This concept paves the way for advanced netted radar setups e.g. in automotive radar and applications with large apertures or baselines or multi-perspective coherent tomographic measurements.
22 March 2019 in IEEE Transactions on Microwave Theory and Techniques
This paper presents a novel coherent full-duplex (FD) double-sided two-way ranging (CFDDS-TWR) technique for wireless locating and velocity measurement between separate radio units. The idea presented here is a quantum leap in wireless locating since it enables coherent ranging, continuous phase tracking, and velocity measurement between wireless units that operate incoherently with separate low-cost crystal oscillator clock sources. Frequency modulated continuous wave chirp sequences are exchanged in a FD manner between two radio units. The signals transmitted from two radio units are received, respectively, by each of the two units and down-converted in a mixer with the receiver's own transmit signal to generate a beat signal in each unit. The two beat signals are then processed together, after one beat signal is transmitted to the partner unit. Phase coherent range and Doppler phase measurements can be conducted between incoherent radio units. The presented CFDDS-TWR technique also offers options for reducing noise-like distortions caused by mixing the products of uncorrelated phase noise. We show both analytically and experimentally that the described compensation method reduces the noise level and enhances the dynamic range of the ranging signals tremendously--as evidenced by an improvement of around 24 dB in our results. These unique signal and synchronization properties show that the CFDDS-TWR method is a highly accurate measurement approach. Results acquired with a 24-GHz test system in a 7- to 17-m range demonstrate a standard deviation in range and velocity of 0.25 mm and 0.05 mm/s, respectively.
5 October 2017 in IEEE Transactions on Antennas and Propagation
In this paper the design and measurement verification of optimized planar sparse arrays for use in wireless localization applications are presented. Existing literature on array optimization has mainly been concerned with arrays intended for imaging applications. As the array requirements for 3-D localization in multipath environments are essentially different, we made an analysis of the array parameters important for this specific application. The set of challenging practically relevant requirements for the optimization of the planar array layout was defined, including a restriction to a small number of antennas and minimal interelement distance bigger than $\lambda /2$ . An adapted multi-objective particle swarm optimization stochastic algorithm was employed to optimize array for the robust and precise direction of arrival of a single source inside a wide angular scan range up to ±60° in azimuth and elevation planes. Two optimized receive arrays consisting of eight patches were manufactured and measured to present the trade-off achieved under the desired requirements. The effects of optimized array parameters on the performance of 3-D positioning are validated by angle measurements in an anechoic chamber and different indoor scenarios.
State-of-the-art radar systems for the contactless monitoring of vital signs and respiratory diseases are typically based on single-channel continuous wave (CW) technology. This technique allows precise measurements of respiration patterns, periods of movement, and heart rate. Major practical problems arise as CW systems suffer from signal cancellation due to destructive interference, limited overall functionality, and a possibility of low signal quality over longer periods. This work introduces a sophisticated multiple-input multiple-output (MIMO) solution that captures a radar image to estimate the sleep pose and position of a person (first step) and determine key vital parameters (second step). The first step is enabled by processing radar data with a forked convolutional neural network, which is trained with reference data captured by a time-of-flight depth camera. Key vital parameters that can be measured in the second step are respiration rate, asynchronous respiratory movement of chest and abdomen and limb movements. The developed algorithms were tested through experiments. The achieved mean absolute error (MAE) for the locations of the xiphoid and navel was less than 5 cm and the categorical accuracy of pose classification and limb movement detection was better than 90% and 98.6%, respectively. The MAE of the breathing rate was measured between 0.06 and 0.8 cycles per minute.
Wireless local positioning systems are based on measurements of signal time of flights and/or bearing angles to determine the position of an active transmitter in 3-D space. Traditional time-of-flight and angle measurements with such positioning systems require many data samples at high rates to fulfill the Nyquist criterion. Moreover, in multipath channels the ability of classical signal processing methods to resolve the delay and bearing vectors of the multiple transmission paths is strictly limited by the radio frequency bandwidth and aperture size. In this paper, we show that the wireless channel is ideally suited for the application of compressed sensing. We can thus reduce the number of samples without major losses in localization performance, or we can improve the resolution. After introducing a general model of a localization task with multipath propagation, and following the definition of key parameters of existing systems, we review the necessary data processing stages with compressed sensing and verify its excellent applicability. Finally, measurements are presented to verify the theoretical predictions experimentally.
15 April 2024 in IEEE Microwave and Wireless Technology Letters
Despite their inability to provide distance or angular information, single-channel continuous-wave radar systems are widely used to measure vital parameters. Their popularity arises from the simplicity of the required components, the low demands on the sampling rate and processing effort, and their low costs. To obtain health data such as respiration rates, heart rates, or heart rate variability, the change of the signal phase due to the displacement of the body surface is measured. Typical signal models in the literature only consider the phase as relevant information and assume that the body surface behaves as a point-like target. This work introduces a more accurate signal model for human respiration based on a circular membrane and demonstrates that the amplitude can also be employed for reliable vital parameter detection.