Nicola Notari

Mr. Nicola Notari

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MGMichael Gottinger
Michael Gottinger
NNNicola Notari
Nicola Notari
SDSamuel Dutler
Samuel Dutler
SKSamuel Kranz
Samuel Kranz
RVRobin Vetsch
Robin Vetsch
GPGuido Piai
Guido Piai
State-of-the-art radar systems for the contactless monitoring of vital signs and respiratory diseases are typically based on single-channel continuous wave (CW) technology. This technique allows precise measurements of respiration patterns, periods of movement, and heart rate. Major practical problems arise as CW systems suffer from signal cancellation due to destructive interference, limited overall functionality, and a possibility of low signal quality over longer periods. This work introduces a sophisticated multiple-input multiple-output (MIMO) solution that captures a radar image to estimate the sleep pose and position of a person (first step) and determine key vital parameters (second step). The first step is enabled by processing radar data with a forked convolutional neural network, which is trained with reference data captured by a time-of-flight depth camera. Key vital parameters that can be measured in the second step are respiration rate, asynchronous respiratory movement of chest and abdomen and limb movements. The developed algorithms were tested through experiments. The achieved mean absolute error (MAE) for the locations of the xiphoid and navel was less than 5 cm and the categorical accuracy of pose classification and limb movement detection was better than 90% and 98.6%, respectively. The MAE of the breathing rate was measured between 0.06 and 0.8 cycles per minute.

15 April 2024 in IEEE Microwave and Wireless Technology Letters
Verified
Journal Article
Closed access
MGMichael Gottinger
Michael Gottinger
NNNicola Notari
Nicola Notari
SKSamuel Kranz
Samuel Kranz
SDSamuel Dutler
Samuel Dutler
RVRobin Vetsch
Robin Vetsch
GPGuido Piai
Guido Piai
Despite their inability to provide distance or angular information, single-channel continuous-wave radar systems are widely used to measure vital parameters. Their popularity arises from the simplicity of the required components, the low demands on the sampling rate and processing effort, and their low costs. To obtain health data such as respiration rates, heart rates, or heart rate variability, the change of the signal phase due to the displacement of the body surface is measured. Typical signal models in the literature only consider the phase as relevant information and assume that the body surface behaves as a point-like target. This work introduces a more accurate signal model for human respiration based on a circular membrane and demonstrates that the amplitude can also be employed for reliable vital parameter detection.