Muhammad Wajih Ullah Siddiqi

Mr. Muhammad Wajih Ullah Siddiqi

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
MSMuhammad Wajih Ullah Siddiqi
Muhammad Wajih Ullah Siddiqi
Joshua LeeJoshua Lee
Joshua Lee
This paper demonstrates the four fold enhancement in quality factor (Q) of a very high frequency (VHF) band piezoelectric Aluminum Nitride (AlN) on Silicon (Si) Lamb mode resonator by applying a unique wide acoustic bandgap (ABG) phononic crystal (PnC) at the anchoring boundaries of the resonator. The PnC unit cell topology, based on a solid disk, is characterized by a wide ABG of 120 MHz around a center frequency of 144.7 MHz from the experiments. The resulting wide ABG described in this work allows for greater enhancement in Q compared to previously reported PnC cell topologies characterized by narrower ABGs. The effect of geometrical variations to the proposed PnC cells on their corresponding ABGs are described through simulations and validated by transmission measurements of fabricated delay lines that incorporate these solid disk PnCs. Experiments demonstrate that widening the ABG associated with the PnC described herein provides for higher Q.

27 August 2019 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
MSMuhammad Wajih Ullah Siddiqi
Muhammad Wajih Ullah Siddiqi
PFPatrick Fedeli
Patrick Fedeli
Cheng TuCheng Tu
Cheng Tu
Attilio FrangiAttilio Frangi
Attilio Frangi
Joshua LeeJoshua Lee
Joshua Lee
Even though many thin-film piezoelectric aluminum nitride (AlN) on silicon (Si) Lamb wave resonators have been proposed in the literature, little focus has been set on the modeling of the quality factors Q . Their Qs are associated with numerous dissipation sources, which are often difficult to separate from each other in experiments. Besides, the values of Q measured in experiments can largely deviate from sample-to-sample of the same design. In order to gain better insight into these issues, we have applied numerical models to estimate anchor losses and thermoelastic damping to a large set of AlN-on-Si resonators specifically designed to have significantly different Qs. The data set includes biconvex resonators of different curvatures (designed to reduce anchor losses), regular flat-edge resonators, and different electrode patterns. For the broad range of devices tested, we show that the computed values of Q agree well with the experimental data. In particular, the experimentally measured values of Q in regular flat-edge Lamb wave resonators are due to comparable contributions of the two types of losses.

1 January 2018
Verified
Conference Paper
Closed access
MSMuhammad Wajih Ullah Siddiqi
Muhammad Wajih Ullah Siddiqi
Joshua LeeJoshua Lee
Joshua Lee
We report an AlN-on-Si Lamb wave resonator with a unique wide acoustic bandgap (ABG) phononic crystal (PnC) structure at its anchors that provides an almost 4-fold increase in quality factor (Q). We show that the wider ABG provides for greater suppression of anchor loss and thus higher Q relative to a narrower ABG. Compared to more common circular void PnC structures, the unique PnC structures presented herein based on solid disks offer a 9-fold increase in the ABG size (82MHz vs. 9MHz) at a similar center frequency around 142MHz. The measured improvements in Q over multiple devices are consistent with finite element simulations on tuning the ABG size.

1 June 2018 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
MSMuhammad Wajih Ullah Siddiqi
Muhammad Wajih Ullah Siddiqi
Cheng TuCheng Tu
Cheng Tu
Joshua LeeJoshua Lee
Joshua Lee
Previous work has demonstrated the effectiveness of the biconvex approach in enhancing the quality factor of piezoelectric resonators. This paper explores biconvex resonators in more detail. The first of these considerations include modifying the resonator geometry when extending the mode order to reduce the motional series resistance. Results for applying various curvatures are described to illustrate the effect of resonator length in providing the possibility to reliably enhance quality factor through an optimal range of curvatures. The drawbacks of over-curving biconvex resonators are also elucidated herein. This paper further describes the effect of the electrode geometry (by varying the area coverage and the number of interdigitated transducer electrodes) in the limit where anchor losses in the biconvex resonators have been reduced to the point such that electrode-related losses have a measurable effect.

1 June 2017
Verified
Conference Paper
Closed access
MSMuhammad Wajih Ullah Siddiqi
Muhammad Wajih Ullah Siddiqi
Cheng TuCheng Tu
Cheng Tu
Joshua LeeJoshua Lee
Joshua Lee
This paper analyzes for the first time the effect of incrementally varying the curvature of a MEMS contour mode resonator on its quality factor (Q). The change in curvature is analyzed in terms of the change in width of the acoustic cavity. Our experimental results show that the change in width of the acoustic cavity should be at least half the acoustic wavelength (λ) of the resonant cavity to achieve optimal and consistent improvement in Q. However, curving beyond λ drastically reduces coupling while providing little improvement in Q. We also examine the impact of electrode coverage for Q-enhanced biconvex resonators: Narrowing the width of the electrodes tends to increase Q but shortening the length reduces Q slightly.

1 June 2019
Verified
Conference Paper
Closed access
MSMuhammad Wajih Ullah Siddiqi
Muhammad Wajih Ullah Siddiqi
Joshua LeeJoshua Lee
Joshua Lee
This paper describes the novel use of a hybrid phononic crystal (PnC) array formed by two PnC shapes on anchoring boundaries of a 7 th harmonic Lamb wave aluminum nitride on silicon (AlN-on-Si) resonator. We demonstrate the effect of the hybrid PnC in boosting Q to the order 10 4 . The hybrid PnC array comprises a disk PnC with a wide acoustic bandgap (ABG) and a ring PnC as an intermediary routing layer for input/output (I/O) electrical feeds to more effectively reduce anchor loss. We show that the wide ABG disk PnC provides 47dB of acoustic attenuation in a Lamb wave delay line.