The present study compared the adsorption properties of two plant materials and the waste products after their essential oil extraction for removing Cu(II) ions from contaminated water. Methods like SEM, XRD, nitrogen adsorption, DTA, TGA, FTIR, and XPS were used for characterization of the materials. All materials showed similar porosity and structure, favoring Cu(II) biosorption. The effects of contact time, pH, temperature, sample amount, and initial metal concentration on Cu(II) removal were examined. Optimal pH was 4, with equilibrium reached in less than 10 min. Temperature and sample amount do not significantly influence the biosorption. The experimental data were fitted to the Langmuir, Freundlich, and Dubinin–Radushkevich isotherm models, and maximum adsorption capacities were calculated. The four plant materials proved to be effective biosorbents for removing copper ions from contaminated water. Desorption experiments using 1 M HNO3 and 0.1 M EDTA showed 100% recovery. The reusability of the most effective biosorbent was confirmed through four adsorption/desorption cycles with EDTA. This material was also used to study the possibilities of purifying a real sample of contaminated water.
In the present study, a rapid method based on total reflection X-ray fluorescence (TXRF) was developed to determine chromium in feed and fecal samples, containing chromic oxide. The method uses suspension sample preparation with gallium as an internal standard and does not require chemical reagents or complete sample digestion. Key parameters affecting performance, such as particle size, sample concentration, and acquisition time, were optimized to ensure stable signals and reliable quantification. The method showed a limit of quantification of 24 µg g−1 for Cr2O3 and good precision (relative standard deviations of 3–7% for both feed and fecal samples), at Cr2O3 concentrations in the range of 20–50 mg kg−1. These performance characteristics meets the requirements for digestibility studies. It requires only small sample quantities with minimal preparation. The developed method is suitable for routine analysis, particularly in studies generating large numbers of samples. The accuracy of the method was confirmed through agreement with results obtained using an independent method based on inductively coupled plasma optical emission spectrometry (ICP-OES) after acid digestion. The scatter plot analysis of the results obtained by both methods showed a linear regression line with a slope of 0.978 and a correlation coefficient (R2) of 0.9559, indicating good agreement. The p-value from the paired t-test performed was greater than 0.05, suggesting that the observed differences between paired measurements are not statistically significant at the 95% confidence level. The Bland–Altman analysis demonstrated negligible systematic deviation between the two methods.
29 July 2022 in Proceedings of the Bulgarian Academy of Sciences
The aim of the present study is the effective application of chemometric approach to the elemental composition of a data set of ten ethereal oil plant materials. The contents of 28 essential and toxic mineral elements at main, minor and trace level are determined in each sample by means of direct solid sampling electrothermal vapourization inductively coupled plasma optical emission spectrometry (ETV-ICP-OES) and are subjected to hierarchical and non-hierarchical cluster analysis and principal component analysis. Z-transformation of the raw data, Ward’s method of linkage and squared Euclidean distance as similarity measure are used in order to discover appropriate linkage between the plant materials and between the chemical parameters characterizing them. Thus, the investigated plant samples are classified, depending on their chemical composition. On the other hand, the mineral elements are categorized into several patterns which are related to the specific soil characteristics.