Antonina Kovacheva

Dr. Antonina Kovacheva


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2025 in Journal of Solution Chemistry
Verified
Journal Article
Closed access
PDF file
AKAntonina Kovacheva
Antonina Kovacheva
RIRadost Ilieva
Radost Ilieva
DRDiana Rabadjieva
Diana Rabadjieva
IVIvelin Vladov
Ivelin Vladov
VNVeselin Nanev
Veselin Nanev

3 May 2026 in Molecules
Verified
Journal Article
Open access
PDF file
CTChristina Tzvetkova
Christina Tzvetkova
LILidia Ivanova
Lidia Ivanova
ADAlbena K. Detcheva
Albena K. Detcheva
AKAntonina Kovacheva
Antonina Kovacheva
MSMiroslav Simeonov
Miroslav Simeonov
IKIrina Karadjova
Irina Karadjova
In the present study, a rapid method based on total reflection X-ray fluorescence (TXRF) was developed to determine chromium in feed and fecal samples, containing chromic oxide. The method uses suspension sample preparation with gallium as an internal standard and does not require chemical reagents or complete sample digestion. Key parameters affecting performance, such as particle size, sample concentration, and acquisition time, were optimized to ensure stable signals and reliable quantification. The method showed a limit of quantification of 24 µg g−1 for Cr2O3 and good precision (relative standard deviations of 3–7% for both feed and fecal samples), at Cr2O3 concentrations in the range of 20–50 mg kg−1. These performance characteristics meets the requirements for digestibility studies. It requires only small sample quantities with minimal preparation. The developed method is suitable for routine analysis, particularly in studies generating large numbers of samples. The accuracy of the method was confirmed through agreement with results obtained using an independent method based on inductively coupled plasma optical emission spectrometry (ICP-OES) after acid digestion. The scatter plot analysis of the results obtained by both methods showed a linear regression line with a slope of 0.978 and a correlation coefficient (R2) of 0.9559, indicating good agreement. The p-value from the paired t-test performed was greater than 0.05, suggesting that the observed differences between paired measurements are not statistically significant at the 95% confidence level. The Bland–Altman analysis demonstrated negligible systematic deviation between the two methods.