Thomas Gerhard Schalkhammer

Prof. Dr. Thomas Gerhard Schalkhammer


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2003 in Nanotechnology
Verified
Journal Article
Closed access
PDF file
GBG Bauer
G Bauer
JHJ Hassmann
J Hassmann
HWH Walter
H Walter
JHJ Haglmüller
J Haglmüller
CMC Mayer
C Mayer
TSThomas Gerhard Schalkhammer
Thomas Gerhard Schalkhammer

1 October 2004 in Macromolecular Symposia
Verified
Journal Article
Closed access
PDF file
HRH. Rauter
H. Rauter
VMV. Matyushin
V. Matyushin
YAY. Alguel
Y. Alguel
FPF. Pittner
F. Pittner
TSThomas Gerhard Schalkhammer
Thomas Gerhard Schalkhammer

1 November 2003 in Monatshefte für Chemie - Chemical Monthly
Verified
Journal Article
Closed access
PDF file
HRHarald Rauter
Harald Rauter
MOMarieke Overeijnder
Marieke Overeijnder
DDDuurt Doornbosch
Duurt Doornbosch
TSThomas Gerhard Schalkhammer
Thomas Gerhard Schalkhammer

25 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
NGNorica Carmen Godja
Norica Carmen Godja
SASaied Assadollahi
Saied Assadollahi
MHMelanie Hütter
Melanie Hütter
PMPooyan Mehrabi
Pooyan Mehrabi
NKNarges Khajehmeymandi
Narges Khajehmeymandi
FMFlorentina-Daniela Munteanu
Florentina-Daniela Munteanu
Nickel’s durability and catalytic properties make it essential in the aerospace, automotive, electronics, and fuel cell technology industries. Wastewater analysis typically relies on sensitive but costly techniques such as ICP-MS, AAS, and ICP-AES, which require complex equipment and are unsuitable for on-site testing. This study introduces a novel screen-printed electrode array with 16 chemically and, optionally, electrochemically coated Au electrodes. Its electrochemical response to Ni2+ was tested using Na2SO3 and ChCl-EG deep eutectic solvents as electrolytes. Ni2+ solutions were prepared from NiCl2·6H2O, NiSO4·6H2O, and dry NiCl2. In Na2SO3, the linear detection ranges were 20–196 mM for NiCl2·6H2O and 89–329 mM for NiSO4·6H2O. High Ni2+ concentrations (10–500 mM) were used to simulate industrial conditions. Two linear ranges were observed, likely due to differences in electrochemical behaviour between NiCl2·6H2O and NiSO4·6H2O, despite the identical Na2SO3 electrolyte. Anion effects (Cl− vs. SO42−) may influence response via complexation or ion pairing. In ChCl-EG, a linear range of 0.5–10 mM (R2 = 0.9995) and a detection limit of 1.6 µM were achieved. With a small electrolyte volume (100–200 µL), nickel detection in the nanomole range is possible. A key advantage is the array’s ability to analyze multiple analytes simultaneously via customizable electrode configurations. Future research will focus on nickel detection in industrial wastewater and its potential in the multiplexed analysis of toxic metals. The array also holds promise for medical diagnostics and food safety applications using thiol/Au-based capture molecules.

10 December 2007
Verified
Book Chapter
Closed access
PDF file
CMC. Mayer
C. Mayer
TSThomas Gerhard Schalkhammer
Thomas Gerhard Schalkhammer