KONSTANTINOS ALEXIOU

Dr. KONSTANTINOS ALEXIOU

Department of Physiotherapy, University of Thessaly, Lamía, Stereá Elláda, Greece
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2024 in Hip & Pelvis
Verified
Journal Article
Open access
PDF file
KONSTANTINOS ALEXIOUKONSTANTINOS ALEXIOU
KONSTANTINOS ALEXIOU
Antonios KoutalosAntonios Koutalos
Antonios Koutalos
SVSokratis Varitimidis
Sokratis Varitimidis
TKTheofilos Karachalios
Theofilos Karachalios
KMKonstantinos Malizos
Konstantinos Malizos
PDPh D
Ph D
Konstantinos Alexiou, MD, PhD, Antonios A. Koutalos, MD, PhD, Sokratis Varitimidis, MD, PhD, Theofilos Karachalios, MD, PhD, Konstantinos N. Malizos, MD, PhD. Hip Pelvis 2024;36:135-43. https://doi.org/10.5371/hp.2024.36.2.135

5 August 2025 in Muscles
Verified
Journal Article
Open access
PDF file
Georgios SidiropoulosGeorgios Sidiropoulos
Georgios Sidiropoulos
Nikolaos StrimpakosNikolaos Strimpakos
Nikolaos Strimpakos
AKAsimakis Kanellopoulos
Asimakis Kanellopoulos
MTMaria Tsekoura
Maria Tsekoura
KONSTANTINOS ALEXIOUKONSTANTINOS ALEXIOU
KONSTANTINOS ALEXIOU
ZDZacharias Dimitriadis
Zacharias Dimitriadis
Background: The reliable assessment of cervical muscle morphology is essential for both clinical and research use. However, evidence on the reliability of ultrasound measurements remains limited. Objective: To investigate the intra-rater and test–retest reliability of morphological measurements of the Longus Colli, Sternocleidomastoid, Multifidus Cervicis, and Semispinalis Capitis muscles using musculoskeletal ultrasound. Methods: Cross-sectional area, anteroposterior, and lateral dimensions were assessed using B-mode ultrasound. Anterior neck muscles were scanned in the supine position, while posterior neck muscles were scanned in the prone position. Each muscle was measured three times (to assess intra-rater reliability), which was repeated after 30 min (to assess test–retest reliability). Measurements were also normalized according to BMI and neck circumference. Results: Intra-rater reliability was found to be good to excellent for the Longus Colli (ICC = 0.77–0.92), excellent for the Sternocleidomastoid (ICC = 0.93–0.99), good to excellent for the Semispinalis Capitis (ICC = 0.89–0.97), and moderate to excellent for the Multifidus Cervicis (ICC = 0.69–0.92). Test–retest reliability was found to be moderate to good for the Longus Colli (ICC = 0.73–0.87), good to excellent for the Sternocleidomastoid (ICC = 0.84–0.98), good to excellent for the Semispinalis Capitis (ICC = 0.78–0.95), and good to excellent for the Multifidus Cervicis (ICC = 0.80–0.92). Conclusions: Musculoskeletal ultrasound demonstrates strong reliability for cervical muscle assessment, supporting its clinical use.