Asimakis Kanellopoulos

Dr. Asimakis Kanellopoulos

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2022 in Cureus
Verified
Journal Article
Open access
ASApostolos Zacharias Skouras
Apostolos Zacharias Skouras
AKAsimakis Kanellopoulos
Asimakis Kanellopoulos
SSSophia Stasi
Sophia Stasi
ATAthanasios Triantafyllou
Athanasios Triantafyllou
PKPanagiotis Koulouvaris
Panagiotis Koulouvaris
GPGeorge Papathanasiou
George Papathanasiou
Q-angle represents the resultant force vector of the quadriceps and patellar tendons acting on the patella. An increased Q-angle has been considered a risk factor for many disorders and injuries. This literature review challenges the clinical value of static Q-angle and recommends a more dynamic movement evaluation for making clinical decisions. Although there are many articles about static Q-angle, few have assessed the value of dynamic Q-angle. We searched Scopus and PubMed (until September 2021) to identify and summarize English-language articles evaluating static and dynamic Q-angle, including articles for dynamic knee valgus (DKV) and frontal plane projection angle. We also used textbooks and articles from references to related articles. Although static Q-angle measurement is used systematically in clinical practice for critical clinical decisions, its interpretation and clinical translation present fundamental and intractable limitations. To date, it is acceptable that mechanisms that cause patellofemoral pain and athletic injuries have a stronger correlation with dynamic loading conditions. Dynamic Q-angle has the following three dynamic elements: frontal plane (hip adduction, knee abduction), transverse plane (hip internal rotation and tibia external rotation), and patella behavior. Measuring one out of three elements (frontal plane) illustrates only one-third of this concept. Static Q-angle lacks biomechanical meaning and utility for dynamic activities. Although DKV is accompanied by hip and tibia rotation, it remains a frontal plane measurement, which provides no information about the transverse plane and patella movement. However, given the acceptable reliability and the better differentiation capability, DKV assessment is recommended in clinical practice.

1 March 2023 in Journal of Chiropractic Medicine
Verified
Journal Article
Closed access
Konstantinos VassisKonstantinos Vassis
Konstantinos Vassis
AKAsimakis Kanellopoulos
Asimakis Kanellopoulos
IPIoannis Poulis
Ioannis Poulis
DKDimitra Kakolyri
Dimitra Kakolyri
ALAggeliki Loukopoulou
Aggeliki Loukopoulou
IPIoannis A Poulis
Ioannis A Poulis
The purpose of this study was to determine the extent to which the mean peak moment (MPM) of knee flexors and extensors could predict performance in a group of healthy individuals. Eighty-four healthy individuals-32 men and 52 women (mean age, 22.1 ± 3 years; range, 18-35 years)-participated in this study. Isokinetic unilateral concentric knee flexor and extensor MPM was assessed isokinetically at angular velocities of 60°/s and 180°/s. Functional performance was assessed using the single hop of distance (SHD). Positive moderate to good statistically significant correlations (r = .636 to r = .673) were found between knee flexor and extensor MPM at 60°/s and 180°/s for the SHD test. Knee flexor and extensor MPMs are strong predictors for the SHD test at 60°/s and 180°/s (R2 = .40 to R2 = .45). Knee flexor and extensor strength was substantially correlated with SHD.

14 December 2021 in Cureus
Verified
Journal Article
Open access
AKAsimakis Kanellopoulos
Asimakis Kanellopoulos
EKEmmanouil K. Kanellopoulos
Emmanouil K. Kanellopoulos
ZDZacharias Dimitriadis
Zacharias Dimitriadis
Nikolaos StrimpakosNikolaos Strimpakos
Nikolaos Strimpakos
AKAndriana Koufogianni
Andriana Koufogianni
IPIoannis A Poulis
Ioannis A Poulis
Pain drawings (PDs) are an important component of the assessment of a patient with pain. Although analog pain drawings (APDs), such as pen-on-paper drawings, have been extensively used in clinical assessment and clinical research, there is a lack of digital pain drawing (DPD) software that would be able to quantify and analyze the digital pain distribution obtained by the patients. The aim of this work is to describe a method that can quantify the extent and location of pain through novel custom-built software able to analyze data from the digital pain drawings obtained from the patients. The application analysis and software specifications were based on the information gathered from the literature, and the programmers created the custom-built software according to the published needs of the pain scientific community. We developed a custom-built software named “Pain Distribution,” which, among others, automatically calculates the number of the pixels the patient has chosen and therefore quantifies the pain extent, provides the frequency distribution from a group of images, and has the option to select the threshold over which the patient is considered with central sensitization (CS). Additionally, it delivers results and statistics for both every image and the frequency distribution, providing mean values, standard deviations, and CS indicators, as well as the ability to export them in *.txt file format for further analysis. A novel Pain Distribution application was developed, freely available for use in any setting, clinical, research, or academic.

15 November 2024 in Muscles
Verified
Journal Article
Open access
PDF file
AKAlexandros Kastrinis
Alexandros Kastrinis
Nikolaos StrimpakosNikolaos Strimpakos
Nikolaos Strimpakos
George A. KoumantakisGeorge A. Koumantakis
George A. Koumantakis
DTDionysios Tzatzaliaris
Dionysios Tzatzaliaris
MOMARIANNA OIKONOMAKI
MARIANNA OIKONOMAKI
ZDZacharias Dimitriadis
Zacharias Dimitriadis
Background: The presence of sensorimotor control deficits in adolescent idiopathic scoliosis compared to typically developed adolescents is supported by the literature but lacks reliability studies for assessment in this population. This study aimed to assess the reliability of eight sensorimotor control tests, in terms of static and dynamic balance, joint position sense (JPS) tests of the extremities and the spine, and a functional upper extremity proprioceptive test in adolescent idiopathic scoliosis subjects. Methods: Sixty adolescent idiopathic scoliosis subjects were divided into four groups. Each group underwent two tests by the same examiner, repeated at 15 min intervals. Reliability was measured using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD). Results: The results showed high reliability for the upper extremity functional proprioception test, for the dynamic and static balance test, and for the spinal lateral flexion joint position sense test in both directions. On the other hand, the shoulder external rotation, knee extension, elbow flexion, and spinal flexion joint position sense tests demonstrated poor reliability in adolescent idiopathic scoliosis subjects. Conclusions: Therapists are recommended to use the functional upper extremity proprioception test, the Fukuda test, the static balance test using a force footplate, and the spinal lateral flexion joint position sense test for assessing treatment progress in this population.

5 August 2025 in Muscles
Verified
Journal Article
Open access
PDF file
Georgios SidiropoulosGeorgios Sidiropoulos
Georgios Sidiropoulos
Nikolaos StrimpakosNikolaos Strimpakos
Nikolaos Strimpakos
AKAsimakis Kanellopoulos
Asimakis Kanellopoulos
MTMaria Tsekoura
Maria Tsekoura
KONSTANTINOS ALEXIOUKONSTANTINOS ALEXIOU
KONSTANTINOS ALEXIOU
ZDZacharias Dimitriadis
Zacharias Dimitriadis
Background: The reliable assessment of cervical muscle morphology is essential for both clinical and research use. However, evidence on the reliability of ultrasound measurements remains limited. Objective: To investigate the intra-rater and test–retest reliability of morphological measurements of the Longus Colli, Sternocleidomastoid, Multifidus Cervicis, and Semispinalis Capitis muscles using musculoskeletal ultrasound. Methods: Cross-sectional area, anteroposterior, and lateral dimensions were assessed using B-mode ultrasound. Anterior neck muscles were scanned in the supine position, while posterior neck muscles were scanned in the prone position. Each muscle was measured three times (to assess intra-rater reliability), which was repeated after 30 min (to assess test–retest reliability). Measurements were also normalized according to BMI and neck circumference. Results: Intra-rater reliability was found to be good to excellent for the Longus Colli (ICC = 0.77–0.92), excellent for the Sternocleidomastoid (ICC = 0.93–0.99), good to excellent for the Semispinalis Capitis (ICC = 0.89–0.97), and moderate to excellent for the Multifidus Cervicis (ICC = 0.69–0.92). Test–retest reliability was found to be moderate to good for the Longus Colli (ICC = 0.73–0.87), good to excellent for the Sternocleidomastoid (ICC = 0.84–0.98), good to excellent for the Semispinalis Capitis (ICC = 0.78–0.95), and good to excellent for the Multifidus Cervicis (ICC = 0.80–0.92). Conclusions: Musculoskeletal ultrasound demonstrates strong reliability for cervical muscle assessment, supporting its clinical use.

20 November 2025 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Closed access
ELEleftheria Lagouvardou
Eleftheria Lagouvardou
IPIoannis Poulis
Ioannis Poulis
Konstantinos VassisKonstantinos Vassis
Konstantinos Vassis
ZDZacharias Dimitriadis
Zacharias Dimitriadis
AKAsimakis Kanellopoulos
Asimakis Kanellopoulos
IPIoannis A Poulis
Ioannis A Poulis