H. Ahammer

H. Ahammer

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Frontiers in Cellular Neuroscience
Verified
Journal Article
Open access
AKAudrey Karperien
Audrey Karperien
HAH. Ahammer
H. Ahammer
HJHerbert Jelinek
Herbert Jelinek
It is well established that microglial form and function are inextricably linked. In recent years, the traditional view that microglial form ranges between "ramified resting" and "activated amoeboid" has been emphasized through advancing imaging techniques that point to microglial form being highly dynamic even within the currently accepted morphological categories. Moreover, microglia adopt meaningful intermediate forms between categories, with considerable crossover in function and varying morphologies as they cycle, migrate, wave, phagocytose, and extend and retract fine and gross processes. From a quantitative perspective, it is problematic to measure such variability using traditional methods, but one way of quantitating such detail is through fractal analysis. The techniques of fractal analysis have been used for quantitating microglial morphology, to categorize gross differences but also to differentiate subtle differences (e.g., amongst ramified cells). Multifractal analysis in particular is one technique of fractal analysis that may be useful for identifying intermediate forms. Here we review current trends and methods of fractal analysis, focusing on box counting analysis, including lacunarity and multifractal analysis, as applied to microglial morphology.

1 February 2009 in Journal of Lipid Research
Verified
Journal Article
Open access
PDF file
AKAdelheid Kratzer
Adelheid Kratzer
MBMarlene Buchebner
Marlene Buchebner
TPThomas Pfeifer
Thomas Pfeifer
TBTatjana M. Becker
Tatjana M. Becker
GUGeorg Uray
Georg Uray
DKDagmar Kratky
Dagmar Kratky
Adelheid Kratzer, Marlene Buchebner, Thomas Pfeifer, Tatjana M. Becker, Georg Uray, Makoto Miyazaki, Shinobu Miyazaki-Anzai, Birgit Ebner, Prakash G. Chandak, Rajendra S. Kadam, Emine Calayir, Nora Rathke, Helmut Ahammer, Branislav Radovic, Michael Trauner, Gerald Hoefler, Uday B. Kompella, Guenter Fauler, Moshe Levi, Sanja Levak-Frank, Gerhard M. Kostner, Dagmar Kratky

6 February 2009 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
APAnton J. Prassl
Anton J. Prassl
FKFerdinand Kickinger
Ferdinand Kickinger
HAH. Ahammer
H. Ahammer
VGVicente Grau
Vicente Grau
JSJürgen E. Schneider
Jürgen E. Schneider
GPG. Plank
G. Plank
Significant advancements in imaging technology and the dramatic increase in computer power over the last few years broke the ground for the construction of anatomically realistic models of the heart at an unprecedented level of detail. To effectively make use of high-resolution imaging datasets for modeling purposes, the imaged objects have to be discretized. This procedure is trivial for structured grids. However, to develop generally applicable heart models, unstructured grids are much preferable. In this study, a novel image-based unstructured mesh generation technique is proposed. It uses the dual mesh of an octree applied directly to segmented 3-D image stacks. The method produces conformal, boundary-fitted, and hexahedra-dominant meshes. The algorithm operates fully automatically with no requirements for interactivity and generates accurate volume-preserving representations of arbitrarily complex geometries with smooth surfaces. The method is very well suited for cardiac electrophysiological simulations. In the myocardium, the algorithm minimizes variations in element size, whereas in the surrounding medium, the element size is grown larger with the distance to the myocardial surfaces to reduce the computational burden. The numerical feasibility of the approach is demonstrated by discretizing and solving the monodomain and bidomain equations on the generated grids for two preparations of high experimental relevance, a left ventricular wedge preparation, and a papillary muscle.

23 December 2015 in British Journal of Sports Medicine
Verified
Journal Article
Open access
PDF file
WMWolfram Müller
Wolfram Müller
TLTimothy G Lohman
Timothy G Lohman
ASArthur D Stewart
Arthur D Stewart
RMRonald J Maughan
Ronald J Maughan
NMNanna L Meyer
Nanna L Meyer
TATimothy R Ackland
Timothy R Ackland
Background: Precise and accurate field methods for body composition analyses in athletes are needed urgently.Aim: Standardisation of a novel ultrasound (US) technique for accurate and reliable measurement of subcutaneous adipose tissue (SAT).Methods: Three observers captured US images of uncompressed SAT in 12 athletes and applied a semiautomatic evaluation algorithm for multiple SAT measurements.Results: Eight new sites are recommended: upper abdomen, lower abdomen, erector spinae, distal triceps, brachioradialis, lateral thigh, front thigh, medial calf. Obtainable accuracy was 0.2 mm (18 MHz probe; speed of sound: 1450 m/s). Reliability of SAT thickness sums (N=36): R2=0.998, SEE=0.55 mm, ICC (95% CI) 0.998 (0.994 to 0.999); observer differences from their mean: 95% of the SAT thickness sums were within ±1 mm (sums of SAT thicknesses ranged from 10 to 50 mm). Embedded fibrous tissues were also measured.Conclusions: A minimum of eight sites is suggested to accommodate inter-individual differences in SAT patterning. All sites overlie muscle with a clearly visible fascia, which eases the acquisition of clear images and the marking of these sites takes only a few minutes. This US method reaches the fundamental accuracy and precision limits for SAT measurements given by tissue plasticity and furrowed borders, provided the measurers are trained appropriately.

1 February 2017 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
PSPaul Störchle
Paul Störchle
WMWolfram Müller
Wolfram Müller
MSMarietta Sengeis
Marietta Sengeis
HAH. Ahammer
H. Ahammer
AFAlfred Fürhapter-Rieger
Alfred Fürhapter-Rieger
Sandra Johanna HolasekSandra Johanna Holasek
Sandra Johanna Holasek
A recently standardized ultrasound technique for measuring subcutaneous adipose tissue (SAT) was applied to normal-weight, overweight and obese persons. Eight measurement sites were used: upper abdomen, lower abdomen, erector spinae, distal triceps, brachioradialis, lateral thigh, front thigh and medial calf. Fat compression was avoided. Fat patterning in 38 participants (body mass index: 18.6-40.3 kgm-2; SAT thickness sums from eight sites: 12-245 mm) was evaluated using a software specifically designed for semi-automatic multiple thickness measurements in SAT (sound speed: 1450 m/s) that also quantifies embedded fibrous structures. With respect to ultrasound intra-observer results, the correlation coefficient ρ = 0.999 (p < 0.01), standard error of the estimate = 1.1 mm and 95% of measurements were within ±2.2 mm. For the normal-weight subgroup, the median measurement deviation was 0.43 mm (1.1% of mean thickness), and for the obese/overweight subgroup it was 0.89 mm (0.5%). The eight sites used here are suggested to represent inter-individual differences in SAT patterning. High measurement accuracy and reliability can be obtained in all groups, from lean to overweight and obese, provided that measurers are trained appropriately.

1 October 2006 in Annals of the New York Academy of Sciences
Verified
Journal Article
Closed access
PDF file
RBRebecca A.B. Burton
Rebecca A.B. Burton
GPGernot Plank
Gernot Plank
JSJürgen E. Schneider
Jürgen E. Schneider
VGVicente Grau
Vicente Grau
HAH. Ahammer
H. Ahammer
PKPeter Kohl
Peter Kohl