Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
4 July 2022 in IEEE Transactions on Instrumentation and Measurement
A measurement component based on fiber Fabry–Pérot (FP) interferometer integrated into a monitoring system for train axle counting is demonstrated. To better understand the characteristics of the sensors and their suitability for rail transport, two sensors with slightly different sensitivities were placed on the foot of the rail in the middle of the sleepers. During the measurement campaign that was carried out on Slovakia regional railway line, the sensors registered passage of the trainset more than 70 times, and their speeds were in the range of approximately from 15 to 65 km/h. The trainset consists of a diesel locomotive and four wagons with different weights and different wears. The traces were divided into five groups according to speeds, while the actual speed differs from the average one by ±1 km/h. Traces obtained by the sensors were filtered. Subsequently, the phase of the signal was obtained and interpolated, and the derivation of the function was performed. If the maximal value of the first derivation of the function is observed, then the axle (wheel) is identified. In case of good technical condition of the vehicle, it is possible to determine the number of axles regardless of the vehicle speed (in our measurement campaign up to 65 km/h and real operation up to 98 km/h) and sensitivity of the sensor. In addition, the noise level in the trace can tell us something about the vehicle’s technical condition.
The work presents the optical fiber sensor for arterial pulse waveform measurement, the operation of which is based on the method of applanation tonometry. The measured optical signal, which is used to determine the arterial pulse waveform at different arterial pulse points is created in the sensor by reflection from two reflective surfaces. The first reflective surface is the front-end surface of the optical fiber, and the second reflective surface is the surface of the flexible membrane that is attached to the arterial pulse point. The reflective surfaces of the sensor create a low-finesse Fabry-Perot cavity from which the optical interference signal is measured in the time domain. In this paper, we show that by analyzing the phase of the interference signal in the time domain it is possible to reconstruct the arterial pulse waveform with high accuracy. Concurrently we document that in interference signals there are well-identifiable places that determine the start of systole, peak systole, dicrotic notch, and end of diastole. We describe the detailed construction of the prepared sensor and the method of its use and we demonstrate using of the sensor in measuring the arterial pulse waveform on the carotid, femoral, radial, and posterior tibial arteries.
30 June 2000 in Communications - Scientific letters of the University of Zilina
In this paper the results of a theoretical analysis and practical investigation of mode interference in single mode optical fibres are described. It is shown that inter-modal interference is a sensitive parameter depending on the quality of an...
This study proposes a Fabry–Perot interferometric system and an associated evaluation method for measuring the weight of moving trains. An optical fiber sensor, comprising a sensing fiber and a supporting structure, is securely bonded to the rail foot. As a train traverses the track, the resulting localized bending induces a change in the sensing fiber’s length, which manifests as a quantifiable phase shift in the interference signal. We developed a physical–mathematical model, based on three Gaussian functions, to describe the temporal change in sensing fiber length caused by the passage of a single bogie. This model enables the determination of a proportionality constant to accurately convert the measured phase change into train weight. Model validation was performed using a train set, including a locomotive and four variably loaded wagons, traveling at 15.47 km/h. This system offers a novel and effective approach for real-time train weight monitoring.
This paper presents a methodology for extracting and simulating arterial pulse waveform signals from Fabry–Perot interferometric measurements, emphasizing a practical approach for noninvasive cardiovascular assessment. A key novelty of this work is the presentation of a complete Python-based processing pipeline, which is made publicly available as open-source code on GitHub (git version 2.39.5). To the authors’ knowledge, no such repository for demodulating these specific interferometric signals to obtain a raw arterial pulse waveform previously existed. The proposed system utilizes accessible Python-based preprocessing steps, including outlier removal, Butterworth high-pass filtering, and min–max normalization, designed for robust signal quality even in settings with common physiological artifacts. Key features such as the rate of change, the Hilbert transform of the rate of change (envelope), and detected extrema guide the signal reconstruction, offering a computationally efficient pathway to reveal its periodic and phase-dependent dynamics. Visual analyses highlight amplitude variations and residual noise sources, primarily attributed to sensor bandwidth limitations and interpolation methods, considerations critical for real-world deployment. Despite these practical challenges, the reconstructed arterial pulse waveform signals provide valuable insights into arterial motion, with the methodology’s performance validated on measurements from three subjects against synchronized ECG recordings. This demonstrates the viability of Fabry–Perot sensors as a potentially cost-effective and readily implementable tool for noninvasive cardiovascular diagnostics. The results underscore the importance of precise yet practical signal processing techniques and pave the way for further improvements in interferometric sensing, bio-signal analysis, and their translation into clinical practice.