The work presents the optical fiber sensor for arterial pulse waveform measurement, the operation of which is based on the method of applanation tonometry. The measured optical signal, which is used to determine the arterial pulse waveform at different arterial pulse points is created in the sensor by reflection from two reflective surfaces. The first reflective surface is the front-end surface of the optical fiber, and the second reflective surface is the surface of the flexible membrane that is attached to the arterial pulse point. The reflective surfaces of the sensor create a low-finesse Fabry-Perot cavity from which the optical interference signal is measured in the time domain. In this paper, we show that by analyzing the phase of the interference signal in the time domain it is possible to reconstruct the arterial pulse waveform with high accuracy. Concurrently we document that in interference signals there are well-identifiable places that determine the start of systole, peak systole, dicrotic notch, and end of diastole. We describe the detailed construction of the prepared sensor and the method of its use and we demonstrate using of the sensor in measuring the arterial pulse waveform on the carotid, femoral, radial, and posterior tibial arteries.
This article deals with the physical principle of operation of the optical fiber sensor, a description of its construction, use, and an analysis of the interference signal that the sensor provides when measuring the pulse pressure wave in the jugular vein. The interference signal is created in the reflected light due to the reflection from the low-finesse Fabry–Perot cavity (FPC) composed of the front end of the optical fiber and a flexible membrane. The flexible membrane of the sensor is applied to the pulse area of the jugular vein, where the operational range is maintained by limiting skin compression to approximately 1 mm to preserve signal visibility. By phase demodulation of the interference signal using an extrema-detection algorithm, a measurement resolution of λ/4 (approximately 388 nm) is achieved. The obtained jugular venous pulse waveform (JVPW) carries information about the state of the right side of the heart, specifically revealing characteristic a, c, v peaks and x, y descents. The operation of the sensor, which is specifically optimized for high-sensitivity detection of low-pressure venous signals, was verified on five healthy human subjects by simultaneously measuring the interference signal and a synchronized electrocardiogram (ECG). A comparison of the obtained JVPWs with ECG signals showed that the waveforms contain all significant physiological features. The results demonstrate that the described sensor allows obtaining JVPWs in a simple, accurate way for use in the diagnosis of heart diseases.
This paper presents a methodology for extracting and simulating arterial pulse waveform signals from Fabry–Perot interferometric measurements, emphasizing a practical approach for noninvasive cardiovascular assessment. A key novelty of this work is the presentation of a complete Python-based processing pipeline, which is made publicly available as open-source code on GitHub (git version 2.39.5). To the authors’ knowledge, no such repository for demodulating these specific interferometric signals to obtain a raw arterial pulse waveform previously existed. The proposed system utilizes accessible Python-based preprocessing steps, including outlier removal, Butterworth high-pass filtering, and min–max normalization, designed for robust signal quality even in settings with common physiological artifacts. Key features such as the rate of change, the Hilbert transform of the rate of change (envelope), and detected extrema guide the signal reconstruction, offering a computationally efficient pathway to reveal its periodic and phase-dependent dynamics. Visual analyses highlight amplitude variations and residual noise sources, primarily attributed to sensor bandwidth limitations and interpolation methods, considerations critical for real-world deployment. Despite these practical challenges, the reconstructed arterial pulse waveform signals provide valuable insights into arterial motion, with the methodology’s performance validated on measurements from three subjects against synchronized ECG recordings. This demonstrates the viability of Fabry–Perot sensors as a potentially cost-effective and readily implementable tool for noninvasive cardiovascular diagnostics. The results underscore the importance of precise yet practical signal processing techniques and pave the way for further improvements in interferometric sensing, bio-signal analysis, and their translation into clinical practice.
One of the ways we can motivate young people is by implementing Children’s Universities as a form of motivating young people for future studies in science and technology. Young people expect a wide use of information and communication technologies in education. They are eager to work actively and implement their own ideas. Children up to the age of 10 undoubtedly have a real but hidden interest in natural and technical sciences, they want to become scientists and explorers. However, after a few years of education at the primary level, the situation changes completely. Simple acoustic experiments included in the teaching from the lowest levels of the education system stimulate children from early childhood to explore and lead from initial play to subsequent experimentation and discovery of new knowledge. Initial playful experimentation that involves multiple child senses (hearing, sight, and touch) stimulates experimentation at the time of primary education and later at the time of secondary and tertiary education in technical universities motivates analysis and evaluation at higher levels of cognitive goals according to Bloom’s taxonomy.