Surdu-Bob Cristina

Dr. Surdu-Bob Cristina


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2021 in Coatings
Verified
Journal Article
Open access
PDF file
DDDiana Diniasi
Diana Diniasi
Florentina GolgoviciFlorentina Golgovici
Florentina Golgovici
AAAlexandru Anghel
Alexandru Anghel
Elena Manuela FulgerElena Manuela Fulger
Elena Manuela Fulger
SCSurdu-Bob Cristina
Surdu-Bob Cristina
Ioana DemetrescuIoana Demetrescu
Ioana Demetrescu
The manuscript is focused on corrosion behavior of a Cr coating under CANada Deuterium Uranium(CANDU) primary circuit conditions. The Cr coating is obtained via the thermionic vacuum arc procedure on Zircaloy -4 cladding. The surface coating characterization was performed using metallographic analysis and scanning electron microscopy (SEM) with an energy dispersive spectra detector (EDS), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) investigations. The thickness of the Cr coating determined from SEM images is around 500 nm layers After the autoclaving period, the thickness of the samples increased in time slowly. The kinetic of oxidation established a logarithmic oxidation law. The corrosion tests for various autoclaving periods of time include electrochemical impedance spectroscopy (EIS) and potentiodynamic tests, permitting computing porosity and efficiency of protection. All surface investigations sustain electrochemical results and promote the Cr coating on Zircaloy-4 alloy autoclaved for 3024 h as the best corrosion resistance based on decrease in corrosion current density values simultaneously with the increase of the time spent in autoclave. A slow increase of Vickers micro hardness was observed as a function of the autoclaved period as well. The value reached for 3024 h being 219 Kgf/mm2 compared with 210 Kgf/mm2 value before autoclaving.

15 January 2019 in Veterinary and Comparative Orthopaedics and Traumatology
Verified
Journal Article
Closed access
PDF file
EVEne Vlase
Ene Vlase
FBFlorica Barbuceanu
Florica Barbuceanu
DTDanut Turcu
Danut Turcu
MCMariana Coman
Mariana Coman
MBMarius Badulescu
Marius Badulescu
SCSurdu-Bob Cristina
Surdu-Bob Cristina
Objective We investigated the benefits of a local preventive therapy based on copper beads against severe bone infection using a rabbit open tibial fracture model. Materials and Methods Cotton mesh balls soaked in a very high concentration of Staphylococcus aureus ATCC 6538 culture were inoculated in drilled holes of the tibiae of treated and control groups. The treated group was also implanted with small copper beads simultaneously, as prevention therapy. Results Survival rate in the treated group was 67% compared with 25% in the control group (difference 40%, for a 95% confidence interval: 40%, 93.4%). The few remaining animals in the control group had bone lesions which developed into osteomyelitis, while the tibiae of treated group had clear signs of reparatory processes. Sixty days after inoculation, signs of local-only toxicity were observed in healthy tibia of a separate non-infected control group. Drawbacks of copper toxicity were weighed against the threat of septicaemia and also against prolonged use of powerful systemic antibiotic medications in severe bone contamination. Cinical Significance It was found that the proposed therapy prevented septicaemia and the spread of infection, and it also induced reparatory processes. The findings of this study may be relevant in antisepsis of open fractures in less appropriate medical settings (such as military camps or remote locations), as well as in severe bone infections. Carmen Cristina Surdu-Bob and Cristin Coman contributed to conception of study, study design, acquisition of data and data analysis and interpretation. Ene Vlase contributed to study design, acquisition of data and data analysis and interpretation. Florica Barbuceanu, Danut Turcu, Mariana Coman, Marius Badulescu and Mariana Oporanu contributed to acquisition of data and data analysis and interpretation. Carmen Cristina Surdu-Bob and Cristin Coman drafted, revised and approved the submitted manuscript. Ene Vlase, Florica Barbuceanu, Danut Turcu, Mariana Coman, Marius Badulescu and Mariana Oporanu approved the submitted manuscript.

2 June 2016 in Medical Engineering & Physics
Verified
Journal Article
Closed access
SCSurdu-Bob Cristina
Surdu-Bob Cristina
CCCristin Coman
Cristin Coman
FBFlorica Barbuceanu
Florica Barbuceanu
DTDanut Turcu
Danut Turcu
NBNicolae Bercaru
Nicolae Bercaru
MBMarius Badulescu
Marius Badulescu
Reproducible animal models of osteomyelitis close to the clinical scenario are difficult to obtain as the animals either die shortly after inoculation of bacteria or the bone cures itself of infection. Additional materials used as foreign bodies offer increased chances for localized infection due to bacterial attachment and are closer to clinical pathology. Through in vivo experimentation we investigated here the influence of surface area of a series of foreign bodies on the final outcome of the animal model, in terms of reproducibility, survival rate and time necessary for onset of chronic disease. Stainless steel Kirschner wire segments, stainless steel balls and cotton meshes were employed for this purpose. The clinical, microbiological, radiological and histological results obtained were compared with the simple case where no foreign body was used. The follow-up period was 57days. The cotton meshes, which had the highest surface area, were observed to provide the best outcome, with the lowest disease onset time interval (of 1week earlier than the others), the highest survival (of 90%) and disease reproduction rate (90%). The only clinical pattern of the mesh group rabbits was short lived inflammation while the other rabbits presented also some other clinical signs such as rhinorrheas, abscesses, rush and/or dyspnea. Moreover, this model is the most suitable for further treatment studies, as the cotton meshes could be easily removed after disease onset, without any intervention on the bone. This is important, as the treatment would address the bacteria present within the bone parts (marrow, cortex, periosteum etc.) not those forming the biofilm.

26 November 2019 in Coatings
Verified
Journal Article
Open access
PDF file
ASAndrei Bogdan Stoian
Andrei Bogdan Stoian
SCSurdu-Bob Cristina
Surdu-Bob Cristina
AAAlexandru Anghel
Alexandru Anghel
Daniela IonitaDaniela Ionita
Daniela Ionita
Ioana DemetrescuIoana Demetrescu
Ioana Demetrescu
The paper presents the investigation of a series of silver-incorporated diamond-like carbon (Ag-DLC) coatings with increasing Ag content on Ti50Zr and deposited using high voltage anodic plasma (HVAP). The coatings surface properties were analyzed with scanning electron microscope (SEM), atomic force microscope (AFM), and contact angle determinations. Electrochemical tests were performed in Afnor artificial saliva and evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy. Based on these properties, comparisons of coatings performance were linked with the amount of deposited Ag. Increasing the Ag content led to the increase of the corrosion resistance and to the decrease of the forces exhibited on the surface. The hydrophobic character of the coating with the highest Ag amount could prevent thrombosis, thus suggesting its possible use for medical implants.

2 July 2011
Verified
Journal Article
Closed access
SCSurdu-Bob Cristina
Surdu-Bob Cristina
CCCristin Coman
Cristin Coman
ACAna Călugăru
Ana Călugăru
LCLidia Cremer
Lidia Cremer
MBMarius Badulescu
Marius Badulescu
EVEne Vlase
Ene Vlase