Hui Ying Ang

Dr. Hui Ying Ang

Department of Biomedical Engineering, National University of Singapore, Singapore 119077, Singapore
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in International Journal of Cardiology
Verified
Journal Article
Closed access
HAHui Ying Ang
Hui Ying Ang
HBHeerajnarain Bulluck
Heerajnarain Bulluck
PWPhilip Wong
Philip Wong
SVSubbu S. Venkatraman
Subbu S. Venkatraman
YHYingying Huang
Yingying Huang
NFNicolas Foin
Nicolas Foin

1 December 2017 in Arteriosclerosis, Thrombosis, and Vascular Biology
Verified
Journal Article
Closed access
JNJaryl Ng
Jaryl Ng
CBChristos V. Bourantas
Christos V. Bourantas
RTRyo Torii
Ryo Torii
HAHui Ying Ang
Hui Ying Ang
ETERHAN TENEKECIOGLU
ERHAN TENEKECIOGLU
NFNicolas Foin
Nicolas Foin
Local hemodynamic forces are well-known to modulate atherosclerotic evolution, which remains one of the largest cause of death worldwide. Percutaneous coronary interventions with stent implantation restores blood flow to the downstream myocardium and is only limited by stent failure caused by restenosis, stent thrombosis, or neoatherosclerosis. Cumulative evidence has shown that local hemodynamic forces affect restenosis and the platelet activation process, modulating the pathophysiological mechanisms that lead to stent failure. This article first covers the pathophysiological mechanisms through which wall shear stress regulates arterial disease formation/neointima proliferation and the role of shear rate on stent thrombosis. Subsequently, the article reviews the current evidence on (1) the implications of stent design on the local hemodynamic forces, and (2) how stent/scaffold expansion can influence local flow, thereby affecting the risk of adverse events.

1 August 2017 in Journal of Thoracic Disease
Verified
Journal Article
Closed access
PDF file
HAHui Ying Ang
Hui Ying Ang
YHYing Ying Huang
Ying Ying Huang
SLSoo Teik Lim
Soo Teik Lim
PWPhilip Wong
Philip Wong
MJMichael Joner
Michael Joner
NFNicolas Foin
Nicolas Foin
Bioresorbable scaffolds (BRS) were developed to overcome the drawbacks of current metallic drug-eluting stents (DES), such as late in-stent restenosis and caging of the vessel permanently. The concept of the BRS is to provide transient support to the vessel during healing before being degraded and resorbed by the body, freeing the vessel and restoring vasomotion. The mechanical properties of the BRS are influenced by the choice of the material and processing methods. Due to insufficient radial strength of the bioresorbable material, BRS often required large strut profile as compared to conventional metallic DES. Having thick struts will in turn affect the deliverability of the device and may cause flow disturbance, thereby increasing the incidence of acute thrombotic events. Currently, the bioresorbable poly-l-lactic acid (PLLA) polymer and magnesium (Mg) alloys are being investigated as materials in BRS technologies. The bioresorption process, mechanical properties, in vitro observations and clinical outcomes of PLLA-based and Mg-based BRS will be examined in this review.

Verified
Journal Article
Open access
PDF file
DTDaniel Wee Yee Toong
Daniel Wee Yee Toong
HTHan Wei Toh
Han Wei Toh
JNJaryl Chen Koon Ng
Jaryl Chen Koon Ng
PWPhilip En Hou Wong
Philip En Hou Wong
Hwa Liang LeoHwa Liang Leo
Hwa Liang Leo
YHYingying Huang
Yingying Huang
Advances in material science and innovative medical technologies have allowed the development of less invasive interventional procedures for deploying implant devices, including scaffolds for cardiac tissue engineering. Biodegradable materials (e.g., resorbable polymers) are employed in devices that are only needed for a transient period. In the case of coronary stents, the device is only required for 6–8 months before positive remodelling takes place. Hence, biodegradable polymeric stents have been considered to promote this positive remodelling and eliminate the issue of permanent caging of the vessel. In tissue engineering, the role of the scaffold is to support favourable cell-scaffold interaction to stimulate formation of functional tissue. The ideal outcome is for the cells to produce their own extracellular matrix over time and eventually replace the implanted scaffold or tissue engineered construct. Synthetic biodegradable polymers are the favoured candidates as scaffolds, because their degradation rates can be manipulated over a broad time scale, and they may be functionalised easily. This review presents an overview of coronary heart disease, the limitations of current interventions and how biomaterials can be used to potentially circumvent these shortcomings in bioresorbable stents, vascular grafts and cardiac patches. The material specifications, type of polymers used, current progress and future challenges for each application will be discussed in this manuscript.

1 October 2016 in International Journal of Cardiology
Verified
Journal Article
Open access
JNJaryl Ng
Jaryl Ng
NFNicolas Foin
Nicolas Foin
HAHui Ying Ang
Hui Ying Ang
JFJiang Ming Fam
Jiang Ming Fam
SSSayan Sen
Sayan Sen
PWPhilip Wong
Philip Wong
Previously, we examined the difference in stent designs across different sizes for six widely used Drug Eluting Stents (DESs). Although stent post-dilatation to larger diameter is commonly done, typically in the setting of long tapering segment or left-main PCI, there is an increasing recognition that information with regard to the different stent model designs has a critical impact on overexpansion results. This study aims to provide an update on stent model designs for contemporary DES platforms as well as test overexpansion results under with oversized post-dilatation. We studied 6 different contemporary commercially available DES platforms: Synergy, Xience Xpedition, Ultimaster, Orsiro, Resolute Onyx and Biomatrix Alpha. We investigated for each platform the difference in stent designs across different sizes and results obtained after post-expansion with larger balloon sizes. The stents were deployed at nominal diameter and subsequently over expanded using increasingly large post dilatation balloon sizes (4.0, 5.0 and 6.0mm at 14ATM). Light microscopy was used to measure the changes in stent geometry and lumen diameter after over-expansion. For each respective DES platform, the MLD observed after overexpansion of the largest stent size available with a 6.0mm balloon was 5.7mm for Synergy, 5.6mm for Xience, 5.2mm for Orsiro, 5.8mm for Ultimaster, 5.5mm for 4mm Onyx (5.9mm for the 5mm XL size) and 5.8mm for BioMatrix Chroma. This update presents valuable novel insights that may be helpful for careful selection of stent size for contemporary DES based on model designs. Such information is especially critical in left main bifurcation stenosis treatment where overexpansion to larger oversized diameter may be required to ensure full stent apposition.

1 October 2016 in Journal of Controlled Release
Verified
Journal Article
Closed access
GXGordon Minru Xiong
Gordon Minru Xiong
HAHui Ying Ang
Hui Ying Ang
JLJinjie Lin
Jinjie Lin
YLYuan Siang Lui
Yuan Siang Lui
JPJie Liang Phua
Jie Liang Phua
YHYingying Huang
Yingying Huang