Alison Pouch

Dr. Alison Pouch


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2018 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
BRBruno V. Rego
Bruno V. Rego
AKAmir H. Khalighi
Amir H. Khalighi
ADAndrew Drach
Andrew Drach
ELEric K. Lai
Eric K. Lai
APAlison Pouch
Alison Pouch
MSMichael Sacks
Michael Sacks

9 September 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
ABA. M. Bavo
A. M. Bavo
APAlison Pouch
Alison Pouch
Joris DegrooteJoris Degroote
Joris Degroote
JVJ. Vierendeels
J. Vierendeels
JGJ. H. Gorman
J. H. Gorman
PSP. Segers
P. Segers
The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian–Eulerian framework. The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow. The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics.

1 December 2015 in Medical Image Analysis
Verified
Journal Article
Closed access
APAlison Pouch
Alison Pouch
STSijie Tian
Sijie Tian
MTManabu Takebe
Manabu Takebe
JYJiefu Yuan
Jiefu Yuan
RGRobert Gorman
Robert Gorman
PYPaul Yushkevich
Paul Yushkevich

2 August 2023 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
HLHao Liu
Hao Liu
NSNatalie T. Simonian
Natalie T. Simonian
APAlison Pouch
Alison Pouch
PIPaul A Iaizzo
Paul A Iaizzo
JGJoseph H. Gorman
Joseph H. Gorman
MSMichael Sacks
Michael Sacks
While mitral valve (MV) repair remains the preferred clinical option for mitral regurgitation (MR) treatment, long-term outcomes remain suboptimal and difficult to predict. Furthermore, pre-operative optimization is complicated by the heterogeneity of MR presentations and the multiplicity of potential repair configurations. In the present work, we established a patient-specific MV computational pipeline based strictly on standard-of-care pre-operative imaging data to quantitatively predict the post-repair MV functional state. First, we established human mitral valve chordae tendinae (MVCT) geometric characteristics obtained from five CT-imaged excised human hearts. From these data, we developed a finite-element model of the full patient-specific MV apparatus that included MVCT papillary muscle origins obtained from both the in vitro study and the pre-operative three-dimensional echocardiography images. To functionally tune the patient-specific MV mechanical behavior, we simulated pre-operative MV closure and iteratively updated the leaflet and MVCT prestrains to minimize the mismatch between the simulated and target end-systolic geometries. Using the resultant fully calibrated MV model, we simulated undersized ring annuloplasty (URA) by defining the annular geometry directly from the ring geometry. In three human cases, the postoperative geometries were predicted to 1 mm of the target, and the MV leaflet strain fields demonstrated close agreement with noninvasive strain estimation technique targets. Interestingly, our model predicted increased posterior leaflet tethering after URA in two recurrent patients, which is the likely driver of long-term MV repair failure. In summary, the present pipeline was able to predict postoperative outcomes from pre-operative clinical data alone. This approach can thus lay the foundation for optimal tailored surgical planning for more durable repair, as well as development of mitral valve digital twins.

5 September 2023 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
NSNatalie T. Simonian
Natalie T. Simonian
HLHao Liu
Hao Liu
SVSneha Vakamudi
Sneha Vakamudi
MPMark J. Pirwitz
Mark J. Pirwitz
APAlison Pouch
Alison Pouch
MSMichael Sacks
Michael Sacks

1 January 2020 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
IOIpek Oguz
Ipek Oguz
NYNatalie Yushkevich
Natalie Yushkevich
APAlison Pouch
Alison Pouch
BOBaris U. Oguz
Baris U. Oguz
JWJiancong Wang
Jiancong Wang
NSNadav Schwartz
Nadav Schwartz
<!-- *** Custom HTML *** --> Purpose: Placental size in early pregnancy has been associated with important clinical outcomes, including fetal growth. However, extraction of placental size from three-dimensional ultrasound (3DUS) requires time-consuming interactive segmentation methods and is prone to user variability. We propose a semiautomated segmentation technique that requires minimal user input to robustly measure placental volume from 3DUS images. Approach: For semiautomated segmentation, a single, central 2D slice was manually annotated to initialize an automated multi-atlas label fusion (MALF) algorithm. The dataset consisted of 47 3DUS volumes obtained at 11 to 14 weeks in singleton pregnancies (28 anterior and 19 posterior). Twenty-six of these subjects were imaged twice within the same session. Dice overlap and surface distance were used to quantify the automated segmentation accuracy compared to expert manual segmentations. The mean placental volume measurements obtained by our method and VOCAL (virtual organ computer-aided analysis), a leading commercial semiautomated method, were compared to the manual reference set. The test–retest reliability was also assessed. Results: The overlap between our automated segmentation and manual (mean Dice: 0.824 ± 0.061, median: 0.831) was within the range reported by other methods requiring extensive manual input. The average surface distance was 1.66 ± 0.96 mm. The correlation coefficient between test–retest volumes was r = 0.88, and the intraclass correlation was ICC ( 1 ) = 0.86. Conclusions: MALF is a promising method that can allow accurate and reliable segmentation of the placenta with minimal user interaction. Further refinement of this technique may allow for placental biometry to be incorporated into clinical pregnancy surveillance.