MRI induced heating on PM leads is a very complex issue. The widely varying results described in literature suggest that there are many factors that influence the degree of heating and that not always are adequately addressed by existing testing methods. We present a wide database of experimental measurements of the heating of metallic wires and PM leads in a 1.5 T RF coil. The aim of these measurements is to systematically quantify the contribution of some potential factors involved in the MRI induced heating: the length and the geometric structure of the lead; the implant location within the body and the lead path; the shape of the phantom used to simulate the human trunk and its relative position inside the RF coil. We found that the several factors are the primary influence on heating at the tip. Closer locations of the leads to the edge of the phantom and to the edge of the coil produce maximum heating. The lead length is the other crucial factor, whereas the implant area does not seem to have a major role in the induced temperature increase. Also the lead structure and the geometry of the phantom revealed to be elements that can significantly modify the amount of heating. Our findings highlight the factors that have significant effects on MRI induced heating of implanted wires and leads. These factors must be taken into account by those who plan to study or model MRI heating of implants. Also our data should help those who wish to develop guidelines for defining safe medical implants for MRI patients. In addition, our database of the entire set of measurements can help those who wish to validate their numerical models of implants that may be exposed to MRI systems.
26 September 2008 in Journal of Magnetic Resonance Imaging
Purpose: To evaluate the effect of the geometry of implantable pacemakers (PMs) on lead heating induced by magnetic resonance imaging (MRI).Materials and Methods: In vitro experiments were conducted with two different setups, using fluoroptic probes to measure the temperature increase. The first experiment consisted of a rectangular box filled with a gelled saline and a pacemaker with its leads. This box was exposed in an MRI birdcage coil to a sinusoidal 64‐MHz field with a calibrated whole‐body specific absorption rate (WB‐SAR) of 1 W/kg. The highest SAR and temperature increase (3000 W/kg, 12°C) occurred for the implant configuration having the largest area. The second experimental setup consisted of a human‐shaped torso filled with gelled saline. In this setup the PM and its lead were exposed to a real MRI scanner, using clinical sequences with WB‐SAR up to 2 W/kg.Results: We found that higher heating occurs for configurations with longer exposed lead lengths and that right chest PMs showed the highest temperature and local SAR (11.9°C, 2345 W/kg), whereas the left chest PMs were less heated (6.3°C, 1362 W/kg). Implant geometry, exposed lead length, and lead area must be considered in the wide variation of temperature increases induced by MRI.Conclusions: The amount of MRI‐induced lead tip heating depends strongly on implant geometry, particularly the lead area, exposed lead length, and position of the implant in the phantom. Critical lead tip heating was found for the longer leads. Therefore, to minimize MRI‐induced lead tip heating, the PM lead should be as short as possible. J. Magn. Reson. Imaging 2008;28:879–886.
The aim of this study was to investigate the mechanisms by which the radiated radiofrequency (RF) GSM (global system for mobile communication) signal may affect pacemaker (PM) function. We measured the signal at the output of the sensing amplifier of PMs with various configurations of low-pass filters. We used three versions of the same PM model: one with a block capacitor which short circuits high-frequency signals; one with a ceramic feedthrough capacitor, a hermetically sealed mechanism connecting the internal electronics to the external connection block, and one with both. The PMs had been modified to have an electrical shielded connection to the output of the sensing amplifier. For each PM, the output of the sensing amplifier was monitored under exposure to modulated and non-modulated RF signals, and to GSM signals (900 and 1800 MHz). Non-modulated RF signals did not alter the response of the PM sensing amplifier. Modulated RF signals showed that the block capacitor did not succeed in short circuiting the RF signal, which is somehow demodulated by the PM internal non-linear circuit elements. Such a demodulation phenomenon poses a critical problem because digital cellular phones use extremely low-frequency modulation (as low as 2 Hz). which can be mistaken for normal heartbeat.
6 April 2006 in Pacing and Clinical Electrophysiology
This article presents two signal processing techniques for the analysis of intracardial electrograins in patients with atrial fibrillation (AF). The first, number of occurrences (NO), is aimed at quantifying the level of organization of the signal. The second, index of synchronization (IS), quantifies the degree of synchrony of electrograms from adjacent atrial sites. The proposed indexes are applied to multielectrode basket catheter recordings in patients with chronic or electrically induced AF