1 January 2008 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
EMEugenio Mattei
Eugenio Mattei
MTMichele Triventi
Michele Triventi
GCGiovanni Calcagnini
Giovanni Calcagnini
Federica CensiFederica Censi
Federica Censi
WKWolfgang Kainz
Wolfgang Kainz
PBPietro Bartolini
Pietro Bartolini
MRI induced heating on PM leads is a very complex issue. The widely varying results described in literature suggest that there are many factors that influence the degree of heating and that not always are adequately addressed by existing testing methods. We present a wide database of experimental measurements of the heating of metallic wires and PM leads in a 1.5 T RF coil. The aim of these measurements is to systematically quantify the contribution of some potential factors involved in the MRI induced heating: the length and the geometric structure of the lead; the implant location within the body and the lead path; the shape of the phantom used to simulate the human trunk and its relative position inside the RF coil. We found that the several factors are the primary influence on heating at the tip. Closer locations of the leads to the edge of the phantom and to the edge of the coil produce maximum heating. The lead length is the other crucial factor, whereas the implant area does not seem to have a major role in the induced temperature increase. Also the lead structure and the geometry of the phantom revealed to be elements that can significantly modify the amount of heating. Our findings highlight the factors that have significant effects on MRI induced heating of implanted wires and leads. These factors must be taken into account by those who plan to study or model MRI heating of implants. Also our data should help those who wish to develop guidelines for defining safe medical implants for MRI patients. In addition, our database of the entire set of measurements can help those who wish to validate their numerical models of implants that may be exposed to MRI systems.

16 January 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
EMEugenio Mattei
Eugenio Mattei
GGGiulia Gentili
Giulia Gentili
FCFederica Censi
Federica Censi
MTMichele Triventi
Michele Triventi
GCGiovanni Calcagnini
Giovanni Calcagnini
Purpose: To assess the risk of radiofrequency (RF) ‐induced heating in patients with MR‐conditional pacemaker (PM) systems, in the presence of another lead abandoned from a previous implant.Methods: Four commercial pacemaker leads were placed beside a MR‐conditional PM system, inside a human trunk simulator. The phantom has been exposed to the RF generated by a 64 MHz body bird‐cage coil (whole‐body specific absorption rate [SAR] = 1 W/kg) and the induced heating was measured at the tip of the abandoned lead and of the MR‐conditional implant. Configurations that maximize the coupling between the RF field and the leads have been tested, as well as realistic implant positions.Results: Abandoned leads showed heating behaviors that strongly depend on the termination condition (abandoned‐capped or saline exposed) and on the lead path (left or right positioning). Given a whole‐body SAR = 1 W/kg, a maximum temperature rise of 17.6°C was observed. The presence of the abandoned lead modifies the RF‐heating profile of the MR‐conditional implant: either an increase or a decrease in the induced heating at its lead tip can occur, mainly depending on the relative position of the two leads. Variations ranging from −63% to +69% with respect to the MR‐conditional system alone were observed.Conclusion: These findings provide experimental evidence that the presence of an abandoned lead poses an additional risk for the patient implanted with a MR‐conditional PM system. Our results support the current PM manufacturers' policy of conditioning the MR compatibility of their systems to the absence of abandoned leads (including leads from MR‐conditional implants). From a clinical point of view, in such cases, the decision whether to perform the exam shall be based upon a risk/benefit evaluation, as in the case of conventional PM systems. Magn Reson Med 73:390–400, 2015.

26 September 2008 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
GCGiovanni Calcagnini
Giovanni Calcagnini
MTMichele Triventi
Michele Triventi
FCFederica Censi
Federica Censi
EMEugenio Mattei
Eugenio Mattei
PBPietro Bartolini
Pietro Bartolini
HBHoward I. Bassen
Howard I. Bassen
Purpose: To evaluate the effect of the geometry of implantable pacemakers (PMs) on lead heating induced by magnetic resonance imaging (MRI).Materials and Methods: In vitro experiments were conducted with two different setups, using fluoroptic probes to measure the temperature increase. The first experiment consisted of a rectangular box filled with a gelled saline and a pacemaker with its leads. This box was exposed in an MRI birdcage coil to a sinusoidal 64‐MHz field with a calibrated whole‐body specific absorption rate (WB‐SAR) of 1 W/kg. The highest SAR and temperature increase (3000 W/kg, 12°C) occurred for the implant configuration having the largest area. The second experimental setup consisted of a human‐shaped torso filled with gelled saline. In this setup the PM and its lead were exposed to a real MRI scanner, using clinical sequences with WB‐SAR up to 2 W/kg.Results: We found that higher heating occurs for configurations with longer exposed lead lengths and that right chest PMs showed the highest temperature and local SAR (11.9°C, 2345 W/kg), whereas the left chest PMs were less heated (6.3°C, 1362 W/kg). Implant geometry, exposed lead length, and lead area must be considered in the wide variation of temperature increases induced by MRI.Conclusions: The amount of MRI‐induced lead tip heating depends strongly on implant geometry, particularly the lead area, exposed lead length, and position of the implant in the phantom. Critical lead tip heating was found for the longer leads. Therefore, to minimize MRI‐induced lead tip heating, the PM lead should be as short as possible. J. Magn. Reson. Imaging 2008;28:879–886.

27 February 2007 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
EMEugenio Mattei
Eugenio Mattei
MTM Triventi
M Triventi
GCG Calcagnini
G Calcagnini
FCF Censi
F Censi
WKW Kainz
W Kainz
PBP Bartolini
P Bartolini
The purpose of this work is to evaluate the error associated with temperature and SAR measurements using fluoroptic temperature probes on pacemaker (PM) leads during magnetic resonance imaging (MRI). We performed temperature measurements on pacemaker leads, excited with a 25, 64, and 128 MHz current. The PM lead tip heating was measured with a fluoroptic thermometer (Luxtron, Model 3100, USA). Different contact configurations between the pigmented portion of the temperature probe and the PM lead tip were investigated to find the contact position minimizing the temperature and SAR underestimation. A computer model was used to estimate the error made by fluoroptic probes in temperature and SAR measurement. The transversal contact of the pigmented portion of the temperature probe and the PM lead tip minimizes the underestimation for temperature and SAR. This contact position also has the lowest temperature and SAR error. For other contact positions, the maximum temperature error can be as high as -45%, whereas the maximum SAR error can be as high as -54%. MRI heating evaluations with temperature probes should use a contact position minimizing the maximum error, need to be accompanied by a thorough uncertainty budget and the temperature and SAR errors should be specified.

12 January 2015 in Neuropsychopharmacology
Verified
Journal Article
Open access
PDF file
EMElena Makovac
Elena Makovac
SGSarah N Garfinkel
Sarah N Garfinkel
ABAndrea Bassi
Andrea Bassi
BBbarbara basile
barbara basile
EMEmiliano Macaluso
Emiliano Macaluso
HCHugo Critchley
Hugo Critchley
Autonomic nervous system activity is an important component of human emotion. Mental processes influence bodily physiology, which in turn feeds back to influence thoughts and feelings. Afferent cardiovascular signals from arterial baroreceptors in the carotid sinuses are processed within the brain and contribute to this two-way communication with the body. These carotid baroreceptors can be stimulated non-invasively by externally applying focal negative pressure bilaterally to the neck. In an experiment combining functional neuroimaging (fMRI) with carotid stimulation in healthy participants, we tested the hypothesis that manipulating afferent cardiovascular signals alters the central processing of emotional information (fearful and neutral facial expressions). Carotid stimulation, compared with sham stimulation, broadly attenuated activity across cortical and brainstem regions. Modulation of emotional processing was apparent as a significant expression-by-stimulation interaction within left amygdala, where responses during appraisal of fearful faces were selectively reduced by carotid stimulation. Moreover, activity reductions within insula, amygdala, and hippocampus correlated with the degree of stimulation-evoked change in the explicit emotional ratings of fearful faces. Across participants, individual differences in autonomic state (heart rate variability, a proxy measure of autonomic balance toward parasympathetic activity) predicted the extent to which carotid stimulation influenced neural (amygdala) responses during appraisal and subjective rating of fearful faces. Together our results provide mechanistic insight into the visceral component of emotion by identifying the neural substrates mediating cardiovascular influences on the processing of fear signals, potentially implicating central baroreflex mechanisms for anxiolytic treatment targets.

26 May 2016 in Scientific Reports
Verified
Journal Article
Open access
Federica CensiFederica Censi
Federica Censi
ICIvan Corazza
Ivan Corazza
ERElisa Reggiani
Elisa Reggiani
GCGiovanni Calcagnini
Giovanni Calcagnini
EMEugenio Mattei
Eugenio Mattei
Giuseppe BorianiGiuseppe Boriani
Giuseppe Boriani
The analysis of P-wave template has been widely used to extract indices of Atrial Fibrillation (AF) risk stratification. The aim of this paper was to assess the potential of the analysis of the P-wave variability over time in patients suffering from atrial fibrillation. P-wave features extracted from P-wave template together with novel indices of P-wave variability have been estimated in a population of patients suffering from persistent AF and compared to those extracted from control subjects. We quantify the P-wave variability over time using three algorithms and we extracted three novel indices: one based on the cross-correlation coefficients among the P-waves (Cross-Correlation Index, CCI), one associated to variation in amplitude of the P-waves (Amplitude Dispersion Index, ADI), one sensible to the phase shift among P-waves (Warping Index, WI). The control group resulted to be characterized by shorter P-wave duration and by a less amount of fragmentation and variability, respect to AF patients. The parameter CCI shows the highest sensitivity (97.3%) and a good specificity (95%).