The current proportional standard device is the most important equipment in the traceability system of current proportional values. Due to the influence of magnetic and capacitive errors, existing current proportional standard devices have the characteristics of high precision and wide variation ratio. This article focuses on the current comparator based on the zero magnetic flux principle, and combines electronic compensation technology with magnetic and capacitive error analysis to develop a new type of wide-variable-ratio self-balancing current comparator. It can achieve many ratio transformations while maintaining high accuracy levels. It can be used to calibrate high-precision standard currents of 0.001 level and below, greatly improving work efficiency. The principle and structure of the wide-variable-ratio self-balancing current comparator are described in the article, and its error performance is theoretically analyzed. Error calibration experiments are also conducted. The test results show that the accuracy of the current comparator with a wide range ratio meets the requirement of 0.0002 level, which can be used to solve the problem of high accuracy and low efficiency in wide range current ratio calibration tests.
25 January 2021 in IEEE Transactions on Instrumentation and Measurement
Two-stage voltage transformer (VT) based on high-voltage excitation is usually less than 10 kV due to insulation limitation. To develop a two-stage VT with high-voltage excitation above 10 kV, this article designed two feasible structures. By calculating and comparing the lengths of the magnetic path, a better structural scheme was selected. The excitation winding and the precise ratio winding are in an “up-and-down” structure. This makes it work at a higher voltage possible. Moreover, a flexible compensation circuit was added to the secondary of this two-stage VT to acquire higher accuracy. Based on the principle, a 500/√3-kV two-stage VT has been developed. The half-symmetry summation method was used to calibrate this two-stage VT. The measurement results indicate that the voltage coefficient is very low. The error is (-2.2 to +3.1) μV/V for the ratio error and (-2.6 to -0.2) μrad for the phase displacement in the range of (20%-120%) rated voltage.
Potential transformers are vital for measuring and protecting the power grid. Their accuracy and reliability directly impact the stability and security of the power system. To address the issues with traditional high-precision potential transformer calibrators, such as cumbersome operation and low efficiency, a high-precision potential transformer calibrator has been developed. The calibrator is based on an embedded system architecture of FPGA and ARM. It uses a high-precision current comparator along with feedback control technology. By monitoring and adjusting the error feedback voltage, it can perform the automated calibration of potential transformers with an accuracy class of 0.0001. The measurement ranges from 0.00001% to 200.0%. This study can be adapted to meet the development needs of modern digital measurement systems.
1 January 2025 in IET Science, Measurement & Technology
The 20 Hz low‐frequency transmission technology is a new type of AC transmission technology based on fully controlled power electronic devices, which has gradually been applied in construction around the world. However, it is difficult to develop high‐precision low‐frequency standard transformers, resulting in a blank system for tracing the values of low‐frequency transformers. Inductive voltage dividers have many advantages such as high accuracy and stability, so low‐frequency voltage ratio standards are suitable for using inductive voltage dividers as the source of traceability. This article proposes the principle of two‐stage excitation and develops a two‐stage excitation low‐frequency induction voltage divider. Based on the finite element method, a three‐dimensional model was established to simulate and optimize the internal electromagnetic field and structure. Designed a closed shielded iron core structure, which has achieved good magnetic field shielding effect; In order to reduce the impact of capacitive leakage, the proportional winding adopts a coaxial cable 10 wire parallel winding method to achieve outer equipotential shielding. Based on the reference potential method, this device is calibrated for errors. The error measurement device uses a lock‐in amplifier SR850. According to the error calibration results, the 10 stage transformation ratio error of the 1 kV two‐stage excitation low‐frequency induction voltage divider is better than 1 × 10 −7 .
1 July 2021 in IOP Conference Series: Earth and Environmental Science
The hot spot temperature of transformers operating in the station area is calculated in real-time using the transformer heat path model as it is impossible to measure the internal winding hot spot temperature directly and modifying the transformer will increase the cost. The smart distribution transformer terminal is an important device for collecting and processing data on the side of the distribution transformer, with a container built from Linux inside to run an application (App) with specific functions developed in the Linux environment. Based on that, the heat circuit model of the transformer is developed into an App installed into the container of the smart distribution transformer terminal to realize the function of the real-time computing and warning of transformer hot spot temperature. It is expected to provide some reference for the transformer operating normally and stably.
Electronic compensation networks used in high–accuracy inductive voltage dividers (IVDs) can introduce temperature– and aging–dependent drift sources, complicating long–term uncertainty evaluation. This paper presents a 1 kV, 10–tap, compensation–free three–stage IVD that combines multi–stage excitation, a closed shielded core, and equipotential coaxial–cable windings to suppress excitation, magnetic–coupling, and capacitive errors. An integrated reference winding is embedded in the third–stage coaxial–cable winding, enabling a simplified bootstrap self–calibration procedure without an additional auxiliary IVD. At 50 Hz, the calibrated ratio error and phase displacement are within 0.08 μV/V and 0.08 μrad, respectively, for all taps, with expanded uncertainties of 0.04 μV/V and 0.06 μrad. Wideband measurements up to 3 kHz further show that the proposed IVD can serve as a voltage–ratio reference for harmonic voltage measurement and calibration.