12 April 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
FZFeng Zhou
Feng Zhou
CJChunyang Jiang
Chunyang Jiang
MLMin Lei
Min Lei
FLFuchang Lin
Fuchang Lin
improvements in the method of determining voltage instrument transformer errors are described in this paper. Two auxiliary instrument transformers are used in series and separately to test the standard voltage instrument transformer under test on the voltage of U and 2U to measure the errors variation between these two voltages. Experimental results showed that the measurement uncertainty of the method were below 5 × 10-6 and 4 μrad at an applied voltage of 110/√ kV. This method is used to finish the traceability of the standard instrument transformers up to 1000kV.

1 January 2019 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
FZFeng Zhou
Feng Zhou
JCJiang Chunyang
Jiang Chunyang
LMLei Min
Lei Min
LFLin Fuchang
Lin Fuchang
YSYang Shihai
Yang Shihai
An ultrahigh‐voltage standard voltage transformer (VT) based on series voltage transformer (SVT) structure is described. A precise isolation VT is designed to realise the connection between the VTs of an SVT. Moreover, the ratio and errors of the SVT are discussed and calculated to reduce the magnetic error of the isolation VT, and capacitor compensation is proposed. Two calibration methods for the SVT are compared. The results are very approaching, and the largest differences between the two methods are <0.08 × 10 −4 and 0.08 min. The results indicate that the errors of an SVT can be obtained by testing at only half the voltage of the SVT.

13 November 2002
Verified
Conference Paper
Closed access
WLWeili Li
Weili Li
FZFeng Zhou
Feng Zhou
HYHou Yunpeng
Hou Yunpeng
CSCheng Shukang
Cheng Shukang
In this paper, 3D equations of heat conduction, boundary conditions and basic hypothesizes of stator solution region are achieved according to heat transfer theory. Based on electromagnetic field theory, the formulation of conductor eddy distributing coefficient in windings is derived. The isoparametric finite element method of hexahedron and eight nodes is used to calculate the 3D stator temperature field of a large salient pole synchronous machine, and numerical simulation method is applied to study the influence of end part leakage field on stator temperature.

25 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HLHao Liu
Hao Liu
FZFeng Zhou
Feng Zhou
LCLixue Chen
Lixue Chen
MLMin Lei
Min Lei
XYXiaodong Yin
Xiaodong Yin
JLJian Liu
Jian Liu
Two-stage voltage transformer (VT) based on high-voltage excitation is usually less than 10 kV due to insulation limitation. To develop a two-stage VT with high-voltage excitation above 10 kV, this article designed two feasible structures. By calculating and comparing the lengths of the magnetic path, a better structural scheme was selected. The excitation winding and the precise ratio winding are in an “up-and-down” structure. This makes it work at a higher voltage possible. Moreover, a flexible compensation circuit was added to the secondary of this two-stage VT to acquire higher accuracy. Based on the principle, a 500/√3-kV two-stage VT has been developed. The half-symmetry summation method was used to calibrate this two-stage VT. The measurement results indicate that the voltage coefficient is very low. The error is (-2.2 to +3.1) μV/V for the ratio error and (-2.6 to -0.2) μrad for the phase displacement in the range of (20%-120%) rated voltage.

24 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
LMLi Mengjia
Li Mengjia
FZFeng Zhou
Feng Zhou
JJJiandong Jiang
Jiandong Jiang
HLHao Liu
Hao Liu
BXBo Xiong
Bo Xiong
TYTeng Yao
Teng Yao
Potential transformers are vital for measuring and protecting the power grid. Their accuracy and reliability directly impact the stability and security of the power system. To address the issues with traditional high-precision potential transformer calibrators, such as cumbersome operation and low efficiency, a high-precision potential transformer calibrator has been developed. The calibrator is based on an embedded system architecture of FPGA and ARM. It uses a high-precision current comparator along with feedback control technology. By monitoring and adjusting the error feedback voltage, it can perform the automated calibration of potential transformers with an accuracy class of 0.0001. The measurement ranges from 0.00001% to 200.0%. This study can be adapted to meet the development needs of modern digital measurement systems.

17 July 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HLHao Liu
Hao Liu
EMEnrico Mohns
Enrico Mohns
JMJohann Meisner
Johann Meisner
CJChunyang Jiang
Chunyang Jiang
FZFeng Zhou
Feng Zhou
LCLixue Chen
Lixue Chen
A two-stage voltage transformer (VT) with several rated transformer ratios and with a rated maximum voltage of 40 kV and a rated minimum voltage of 5 kV has been designed. To guarantee high accuracy over the full medium voltage range, the primary winding has been split into 4 primary windings, which can be configured in three different series and parallel connections. With five windings of the secondary, 15 different voltage ratios can be accomplished. This connection scheme, which is already used in older commercial standard VTs of the error class 0.02, achieves a very low effective output resistance, which in turn results in very small additional errors of less than 0.5·10 -6 due to the loading by the input of the transformer bridge. According to the measuring results, for all the 15 different ratios, the error is less than 20 μV/V for ratio error and 20 μrad for phase displacement.