An appropriate design of a chiller plant is crucial to guarantee highly performing solutions. However, several design variables, such as type of systems, total cooling capacity, and hydraulic arrangement, need to be considered. On the one hand, at present, different technical criteria for selecting the most suitable design variables are available. Studies that corroborate the influence of the design variables over the operational variables are missing. In order to fill this knowledge gap, this work proposes a statistical analysis of design variables in chiller plants operating in medium- and large-scale applications and evaluates their influence on energy consumption and life cycle cost (LCC) under the same thermal demand conditions. A case study involving 138 chiller plant combinations featuring different arrangements and a Cuban hotel was selected. The results suggested that the total chiller design and cooling capacity distribution among chillers have a significant influence on the energy consumption of the chiller plant with a Spearman’s Rho and Kendall Tau (τ) correlation index value of −0.625 and 0.559, respectively. However, with LCC, only the cooling capacity distribution among the chillers had a certain influence with a Kendall Tau correlation index value of 0.289. As for the considered total cooling capacity, the applied statistical test showed that this design variable does not have any influence on performing the chiller plant.
The development of ship propulsion in the areas of Economic Operation, Environmental Protection and Ship Efficiency (Triple E - Economy, Environment, Efficiency) is the comparison standard of the manufacturers of contemporary ships. The standard is based on the application of a more modern design of the diesel engines, the wide use of waste heat and the efficient operation of the ship.In accordance with the Economic Operation, the need to evaluate the design of air conditioning systems has been identified in order to determine the possible savings, which are represented by a decrease in fuel consumption, as a result of: the significant impact of this consumption in the operation of the ship, the current high costs of this energy, the periodic increase in the price of the same, and the international policies for the reduction of emissions to the atmosphere and preservation of the environment.By means of the energy diagnosis of the air conditioning system it is possible to determine the possible opportunities of energy saving during the operation of the ship.The results indicate that the thermal load and the cooling capacity required by the air conditioned spaces have a difference between their maximum and average value of 14%. This justifies the need to use a conditioning system with a variable volume of air supplied to the air conditioned space.
Energy management in the hotel industry remains a cornerstone in mitigating climate change. To successfully deploy energy management practices, correct energy KPIs are needed. Moreover, the development of a uniform taxonomy on how to classify hotel industry final energy use is crucial in succeeding with energy management in the hotel industry and to enable benchmarking beyond the supply of energy. This work proposes a methodology to develop a taxonomy of final energy use in hotels. The methodology consists of five steps and five levels, allowing them to gradually disaggregate the final use of energy following different classification criteria. The methodology is applied to a hotel, validating the feasibility of the proposed methodology to more accurately identify the areas of greatest final energy use and provide further insights. Results indicate that the main electrical energy use emanates from HVAC (30.4%), tap hot water (24.8%), food process (20.6%), and lightning (7.1%). Key findings include the development of a structured framework that allows hotel managers, energy professionals, and policymakers to systematically assess and benchmark energy performance; and the classification levels provide a standardized method for identifying energy-intensive operations, enabling the implementation of targeted energy-saving measures.
This paper presents a procedure for the energy optimization of domestic hot water (DHW) systems in hotels located in tropical climates that use centralized air conditioning systems. The study aims to maximize heat recovery from chillers and reduce the fuel consumption of auxiliary heaters by optimizing operational variables such as water mass flow in the primary and secondary DHW circuits and outlet temperature of the backup system. The optimization is implemented using genetic algorithms (GA), which enable the identification of the most efficient flow configurations under variable thermal demand conditions. The proposed methodology integrates a thermoenergetic model validated with real operational data and considers the dynamic behavior of hotel occupancy and water demand. The results show that the optimized strategy reduces auxiliary heating use by up to 75%, achieving annual energy savings of 8244 kWh, equivalent to 2.3 tons of fuel, and preventing the emission of 10.5 tons of CO2. This study contributes to the design of sustainable energy systems in the hospitality sector and provides replicable strategies for similar climatic and operational contexts.