Ricardo Hanel

Prof. Dr. Ricardo Hanel


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2019 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
RHRicardo Hanel
Ricardo Hanel
DKDavid F Kallmes
David F Kallmes
DLDemetrius Klee Lopes
Demetrius Klee Lopes
PNPeter Kim Nelson
Peter Kim Nelson
ASAdnan Siddiqui
Adnan Siddiqui
APAjit S Puri
Ajit S Puri
Background: Preliminary clinical studies on the safety and efficacy of the pipeline embolization device (PED) for the treatment of small/medium aneurysms have demonstrated high occlusion rates with low complications. Objective: To evaluate the safety and effectiveness of the PED for treatment of wide necked small and medium intracranial aneurysms. Methods: PREMIER is a prospective, multicenter, single arm trial. Patients were treated with the PED for unruptured wide necked aneurysms, measuring ≤12 mm along the internal carotid artery or vertebral artery, between July 2014 and November 2015. At 1 year post-procedure, the primary effectiveness endpoint was complete occlusion (Raymond grade 1) without major parent vessel stenosis (≤50%) or retreatment, and the primary safety endpoint was major stroke in the territory supplied by the treated artery or neurologic death. Results: A total of 141 patients were treated with PEDs (mean age 54.6±11.3 years, 87.9% (124/141) women). Mean aneurysm size was 5.0±1.92 mm, and 84.4% (119/141) measured <7 mm. PED placement was successful in 99.3% (140/141) of patients. Mean number of PEDs implanted per patient was 1.1±0.26; a single PED was used in 92.9% (131/141) of patients. At 1 year, 97.9% (138/141) of patients underwent follow-up angiography with 76.8% (106/138) of patients having met the study’s primary effectiveness endpoint. The combined major morbidity and mortality rate was 2.1% (3/140). Conclusions: Treatment of wide necked small/medium aneurysms with the PED results in high rates of complete occlusion without significant parent vessel stenosis and low rates of permanent neurologic complications. Trial registration: NCT02186561.

21 April 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
WBWaleed Brinjikji
Waleed Brinjikji
GLG. Lanzino
G. Lanzino
HCH.J. Cloft
H.J. Cloft
ASA.H. Siddiqui
A.H. Siddiqui
EBE. Boccardi
E. Boccardi
DKDavid F. Kallmes
David F. Kallmes
BACKGROUND AND PURPOSE: Risk factors for acute ischemic stroke following flow-diverter treatment of intracranial aneurysms are poorly understood. Using the International Retrospective Study of Pipeline Embolization Device (IntrePED) registry, we studied demographic, aneurysm, and procedural characteristics associated with postoperative acute ischemic stroke following Pipeline Embolization Device (PED) treatment. MATERIALS AND METHODS: We identified patients in the IntrePED registry with post-PED-treatment acute ischemic stroke. The rate of postoperative acute ischemic stroke was determined by demographics, comorbidities, aneurysm characteristics, and procedure characteristics (including anticoagulation use, platelet testing, number of devices used, sheaths, and so forth). Categoric variables were compared with χ2 testing, and continuous variables were compared with the Student t test. Odds ratios and 95% confidence intervals were obtained by using univariate logistic regression. Multivariate logistic regression analysis was used to determine which factors were independently associated with postoperative stroke. RESULTS: Of 793 patients with 906 aneurysms, 36 (4.5%) patients had acute ischemic stroke. Twenty-six (72.2%) strokes occurred within 30 days of treatment (median, 3.5 days; range, 0–397 days). Ten patients died, and the remaining 26 had major neurologic morbidity. Variables associated with higher odds of acute ischemic stroke on univariate analysis included male sex, hypertension, treatment of MCA aneurysms, treatment of fusiform aneurysms, treatment of giant aneurysms, and use of multiple PEDs. However, on multivariate analysis, the only one of these variables independently associated with stroke was treatment of fusiform aneurysms (OR, 2.74; 95% CI, 1.11–6.75; P = .03). Fusiform aneurysms that were associated with stroke were significantly larger than those not associated with stroke (mean, 24.5 ± 12.5 mm versus 13.6 ± 6.8 mm; P < .001). CONCLUSIONS: Ischemic stroke following PED treatment is an uncommon-but-devastating complication. Fusiform aneurysms were the only variable independently associated with postoperative stroke.

15 March 2022 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
RHRicardo Hanel
Ricardo Hanel
GCGustavo M Cortez
Gustavo M Cortez
DLDemetrius Klee Lopes
Demetrius Klee Lopes
PNPeter Kim Nelson
Peter Kim Nelson
ASAdnan H Siddiqui
Adnan H Siddiqui
DKDavid F Kallmes
David F Kallmes
Background The pipeline embolization device (PED; Medtronic) has presented as a safe and efficacious treatment for small- and medium-sized intracranial aneurysms. Independently adjudicated long-term results of the device in treating these lesions are still indeterminate. We present 3-year results, with additional application of a flow diverter specific occlusion scale. Methods PREMIER (prospective study on embolization of intracranial aneurysms with pipeline embolization device) is a prospective, single-arm trial. Inclusion criteria were patients with unruptured wide-necked intracranial aneurysms ≤12 mm. Primary effectiveness (complete aneurysm occlusion) and safety (major neurologic event) endpoints were independently monitored and adjudicated. Results As per the protocol, of 141 patients treated with a PED, 25 (17.7%) required angiographic follow-up after the first year due to incomplete aneurysm occlusion. According to the Core Radiology Laboratory review, three (12%) of these patients progressed to complete occlusion, with an overall rate of complete aneurysm occlusion at 3 years of 83.3% (115/138). Further angiographic evaluation using the modified Cekirge–Saatci classification demonstrated that complete occlusion, neck residual, or aneurysm size reduction occurred in 97.1%. The overall combined safety endpoint at 3 years was 2.8% (4/141), with only one non-debilitating major event occurring after the first year. There was one case of aneurysm recurrence but no cases of delayed rupture in this series. Conclusions The PED device presents as a safe and effective modality in treating small- and medium-sized intracranial aneurysms. The application of a flow diverter specific occlusion classification attested the long-term durability with higher rate of successful aneurysm occlusion and no documented aneurysm rupture. Trial registration NCT02186561.

1 September 2022 in Stroke
Verified
Journal Article
Closed access
PDF file
MMMahmoud H. Mohammaden
Mahmoud H. Mohammaden
DHDiogo C. Haussen
Diogo C. Haussen
AAAlhamza R. Al-Bayati
Alhamza R. Al-Bayati
AHAmeer E. Hassan
Ameer E. Hassan
WTWondwossen Tekle
Wondwossen Tekle
RNRaul G. Nogueira
Raul G. Nogueira
Background: Successful reperfusion is one of the strongest predictors of functional outcomes after mechanical thrombectomy (MT). Despite continuous advancements in MT technology and techniques, reperfusion failure still occurs in ≈15% to 30% of patients with large vessel occlusion strokes undergoing MT. We aim to evaluate the safety and efficacy of rescue intracranial stenting for large vessel occlusion stroke after failed MT. Methods: The SAINT (Stenting and Angioplasty in Neurothrombectomy) Study is a retrospective analysis of prospectively collected data from 14 comprehensive stroke centers through January 2015 to December 2020. Patients were included if they had anterior circulation large vessel occlusion stroke due to intracranial internal carotid artery and middle cerebral artery-M1/M2 segments and failed MT. The cohort was divided into 2 groups: rescue intracranial stenting and failed recanalization (modified Thrombolysis in Cerebral Ischemia score 0–1). Propensity score matching was used to balance the 2 groups. The primary outcome was the shift in the degree of disability as measured by the modified Rankin Scale at 90 days. Secondary outcomes included functional independence (90-day modified Rankin Scale score 0–2). Safety measures included symptomatic intracranial hemorrhage and 90-day mortality. Results: A total of 499 patients were included in the analysis. Compared with the failed reperfusion group, rescue intracranial stenting had a favorable shift in the overall modified Rankin Scale score distribution (acOR, 2.31 [95% CI, 1.61–3.32]; P <0.001), higher rates of functional independence (35.1% versus 7%; adjusted odds ratio [aOR], 6.33 [95% CI, 3.14–12.76]; P <0.001), and lower mortality (28% versus 46.5%; aOR, 0.55 [95% CI, 0.31–0.96]; P =0.04) at 90 days. Rates of symptomatic intracerebral hemorrhage were comparable across both groups (7.1% versus 10.2%; aOR, 0.99 [95% CI, 0.42–2.34]; P =0.98). The matched cohort analysis demonstrated similar results. Specifically, rescue intracranial stenting (n=107) had a favorable shift in the overall modified Rankin Scale score distribution (acOR, 3.74 [95% CI, 2.16–6.57]; P <0.001), higher rates of functional independence (34.6% versus 6.5%; aOR, 10.91 [95% CI, 4.11–28.92]; P <0.001), and lower mortality (29.9% versus 43%; aOR, 0.49 [95% CI, 0.25–0.94]; P =0.03) at 90 days with similar rates of symptomatic intracerebral hemorrhage (7.5% versus 11.2%; aOR, 0.87 [95% CI, 0.31–2.42]; P =0.79) compared with patients who failed to reperfuse (n=107). There was no heterogeneity of treatment effect across the prespecified subgroups for improvement in functional outcomes. Conclusions: Acute intracranial stenting appears to be a safe and effective rescue strategy in patients with large vessel occlusion stroke who failed MT. Randomized multicenter trials are warranted.

15 March 2021 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
WBWaleed Brinjikji
Waleed Brinjikji
RNRaul G Nogueira
Raul G Nogueira
PKPeter Kvamme
Peter Kvamme
KLKennith F Layton
Kennith F Layton
JAJosser E Delgado Almandoz
Josser E Delgado Almandoz
DKDavid F Kallmes
David F Kallmes
Background: We retrospectively evaluated the composition of retrieved clots from ischemic stroke patients to study the association between histological composition and stroke etiologyMethods: Consecutive patients enrolled in the Stroke Thromboembolism Registry of Imaging and Pathology (STRIP) were included in this study. All patients underwent mechanical thrombectomy and retrieved clots were sent to a central core lab for processing. Histological analysis was performed using martius scarlet blue (MSB) staining, and quantification for red blood cells (RBCs), white blood cells (WBCs), fibrin and platelets was performed using Orbit Image Software. A Wilcoxon test was used for continuous variables and χ2test for categorical variables.Results: 1350 patients were included in this study. The overall rate of Thrombolysis In Cerebral Infarction (TICI) 2c/3 was 68%. 501 patients received tissue plasminogen activator (tPA) (37%). 267 patients (20%) had a large artery atherosclerosis (LAA) source, 662 (49%) a cardioembolic (CE) source, 301 (22%) were cryptogenic, and the remainder had other identifiable sources including hypercoagulable state or dissection. LAA thrombi had a higher mean RBC density (46±23% vs 42±22%, p=0.01) and a lower platelet density (24±18% vs 27±18%, p=0.03) than CE thrombi. Clots from dissection patients had the highest mean RBC density (50±24%) while clots from patients with a hypercoagulable state had the lowest mean RBC density (26±21%).Conclusions: Our study found statistically significant but clinically insignificant differences between clots of CE and LAA etiologies. Future studies should emphasize molecular, proteomic and immunohistochemical characteristics to determine links between clot composition and etiology.

24 December 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
JHJ.J. Heit
J.J. Heit
HCH. Coelho
H. Coelho
FLF.O. Lima
F.O. Lima
MGM. Granja
M. Granja
AAA. Aghaebrahim
A. Aghaebrahim
FMF. Mont’aLverne
F. Mont’aLverne
BACKGROUND AND PURPOSE: Intracranial hemorrhage (ICH) is an important event that is diagnosed on head NCCT. Increased NCCT utilization in busy hospitals may limit timely identification of ICH. RAPID ICH is an automated hybrid 2D–3D convolutional neural network application designed to detect ICH that may allow for expedited ICH diagnosis. We determined the accuracy of RAPID ICH for ICH detection and ICH volumetric quantification on NCCT. MATERIALS AND METHODS: NCCT scans were evaluated for ICH by RAPID ICH. Consensus detection of ICH by 3 neuroradiology experts was used as the criterion standard for RAPID ICH comparison. ICH volume was also automatically determined by RAPID ICH in patients with intraparenchymal or intraventricular hemorrhage and compared with manually segmented ICH volumes by a single neuroradiology expert. ICH detection accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratios by RAPID ICH were determined. RESULTS: We included 308 studies. RAPID ICH correctly identified 151/158 ICH cases and 143/150 ICH-negative cases, which resulted in high sensitivity (0.956, CI: 0.911–0.978), specificity (0.953, CI: 0.907–0.977), positive predictive value (0.956, CI: 0.911-0.978), and negative predictive value (0.953, CI: 0.907–0.977) for ICH detection. The positive likelihood ratio (20.479, CI 9.928–42.245) and negative likelihood ratio (0.046, CI 0.023–0.096) for ICH detection were similarly favorable. RAPID ICH volumetric quantification for intraparenchymal and intraventricular hemorrhages strongly correlated with expert manual segmentation (correlation coefficient r = 0.983); the median absolute error was 3 mL. CONCLUSIONS: RAPID ICH is highly accurate in the detection of ICH and in the volumetric quantification of intraparenchymal and intraventricular hemorrhages.