Aims: The aim of this study was to report patient and clinical outcomes following robotic-assisted total knee arthroplasty (RA-TKA) at multiple institutions with a minimum two-year follow-up. Methods: This was a multicentre registry study from October 2016 to June 2021 that included 861 primary RA-TKA patients who completed at least one pre- and postoperative patient-reported outcome measure (PROM) questionnaire, including Forgotten Joint Score (FJS), Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement (KOOS JR), and pain out of 100 points. The mean age was 67 years (35 to 86), 452 were male (53%), mean BMI was 31.5 kg/m2 (19 to 58), and 553 (64%) cemented and 308 (36%) cementless implants. Results: There were significant improvements in PROMs over time between preoperative, one- to two-year, and > two-year follow-up, with a mean FJS of 17.5 (SD 18.2), 70.2 (SD 27.8), and 76.7 (SD 25.8; p < 0.001); mean KOOS JR of 51.6 (SD 11.5), 85.1 (SD 13.8), and 87.9 (SD 13.0; p < 0.001); and mean pain scores of 65.7 (SD 20.4), 13.0 (SD 19.1), and 11.3 (SD 19.9; p < 0.001), respectively. There were eight superficial infections (0.9%) and four revisions (0.5%). Conclusion: RA-TKA demonstrated consistent clinical results across multiple institutions with excellent PROMs that continued to improve over time. With the ability to achieve target alignment in the coronal, axial, and sagittal planes and provide intraoperative real-time data to obtain balanced gaps, RA-TKA demonstrated excellent clinical outcomes and PROMs in this patient population. Cite this article: Bone Jt Open 2022;3(7):589–595.
Background: Monitoring knee range of motion (ROM) after total knee arthroplasty (TKA) via clinically deployed wearable motion sensors is increasingly common. Prior work from our own lab showed promising results in one wearable motion sensor system; however, we did not investigate errors across different activities. Accordingly, herein we conducted secondary analyses of error using wearable inertial measurement units (IMUs) quantifying sagittal knee angles across activities in TKA patients. Methods: After Institutional Review Board (IRB) approval, TKA patients were recruited for participation in two visits (n = 20 enrolled, n = 5 lost to follow-up). Following a sensor tutorial (MotionSense, Stryker, Mahwah, NJ, USA), sensors and motion capture (MOCAP) markers were applied for data capture before surgery. One surgeon then performed TKA. An identical data capture was then completed postoperatively. MOCAP and wearable motion sensor knee angles were computed during a series of activities and compared. Two-way ANOVA evaluated the impact of time (pre- vs. post-TKA) and activity on average error. Another two-way ANOVA was completed, assessing if error at local maxima was different than at local minima and if either was different across activities. Results: Pre-TKA/post-TKA errors were not different. No differences were noted across activities. On average, the errors were under clinically acceptable thresholds (i.e., 4.9 ± 2.6° vs. ≤5°). Conclusions: With average error ≤ 5°, these specific sensors accurately quantify knee angles before/after surgical intervention. Future investigations should explore leveraging this type of technology to evaluate preoperative function decline and postoperative function recovery.