Nabeel Mansour

Dr. Nabeel Mansour

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2024 in Chest
Verified
Journal Article
Open access
JRJan Rudolph
Jan Rudolph
CHChristian Huemmer
Christian Huemmer
APAlexander Preuhs
Alexander Preuhs
GBGiulia Buizza
Giulia Buizza
BHBoj F. Hoppe
Boj F. Hoppe
BSBastian O. Sabel
Bastian O. Sabel
Chest radiographs (CXRs) are still of crucial importance in primary diagnostics, but their interpretation poses difficulties at times. Can a convolutional neural network-based artificial intelligence (AI) system that interprets CXRs add value in an emergency unit setting? A total of 563 CXRs acquired in the emergency unit of a major university hospital were retrospectively assessed twice by three board-certified radiologists, three radiology residents, and three emergency unit-experienced nonradiology residents (NRRs). They used a two-step reading process: (1) without AI support; and (2) with AI support providing additional images with AI overlays. Suspicion of four suspected pathologies (pleural effusion, pneumothorax, consolidations suspicious for pneumonia, and nodules) was reported on a five-point confidence scale. Confidence scores of the board-certified radiologists were converted into four binary reference standards of different sensitivities. Performance by radiology residents and NRRs without AI support/with AI support were statistically compared by using receiver-operating characteristics (ROCs), Youden statistics, and operating point metrics derived from fitted ROC curves. NRRs could significantly improve performance, sensitivity, and accuracy with AI support in all four pathologies tested. In the most sensitive reference standard (reference standard IV), NRR consensus improved the area under the ROC curve (mean, 95% CI) in the detection of the time-critical pathology pneumothorax from 0.846 (0.785-0.907) without AI support to 0.974 (0.947-1.000) with AI support (P < .001), which represented a gain of 30% in sensitivity and 2% in accuracy (while maintaining an optimized specificity). The most pronounced effect was observed in nodule detection, with NRR with AI support improving sensitivity by 53% and accuracy by 7% (area under the ROC curve without AI support, 0.723 [0.661-0.785]; with AI support, 0.890 [0.848-0.931]; P < .001). Radiology residents had smaller, mostly nonsignificant gains in performance, sensitivity, and accuracy with AI support. We found that in an emergency unit setting without 24/7 radiology coverage, the presented AI solution features an excellent clinical support tool to nonradiologists, similar to a second reader, and allows for a more accurate primary diagnosis and thus earlier therapy initiation.

7 July 2022 in Journal of Nuclear Cardiology
Verified
Journal Article
Open access
PDF file
NMNabeel Mansour
Nabeel Mansour
SNStephan G. Nekolla
Stephan G. Nekolla
EREliana Reyes
Eliana Reyes
GAGeorge Angelidis
George Angelidis
PGPanagiotis Georgoulias
Panagiotis Georgoulias
CRChristoph Rischpler
Christoph Rischpler
Background Cadmium-zinc-telluride (CZT)-based detectors exhibit higher diagnostic sensitivity in myocardial perfusion imaging (MPI) than conventional Anger-MPI for detection of coronary artery disease (CAD); however, reduced specificity and diagnostic accuracy of CZT-MPI were observed. This study aims to compare these different camera systems and to examine the degree of inter-rater reproducibility among readers with varying experience in MPI. Methods 83 patients who underwent double stress/rest examinations using both a CZT and conventional SPECT cameras within one visit were included. Anonymized and randomized MPI-images were distributed to 15 international readers using a standardized questionnaire. Subsequent coronary angiography findings of ten patients served as a reference for analysis of sensitivity and specificity. Results Image quality was significantly better in CZT-MPI with significantly lower breast attenuation (P < 0.05). CZT-MPI exhibited higher sensitivity than Anger-MPI (87.5% vs. 62.5%) and significantly reduced specificity (40% vs. 100%). Readers experienced with both camera systems had the highest inter-rater agreement indicating higher reproducibility (CZT 0.54 vs. conv. 0.49, P < 0.05). Conclusions Higher diagnostic sensitivity of CZT-MPI offers advantages in detection of CAD yet potentially of at the cost of reduced specificity, therefore it requires special training and a differentiated evaluation approach, especially for non-experienced readers with such camera systems.

1 January 2024 in Clinical Endocrinology
Verified
Journal Article
Open access
NMNabeel Mansour
Nabeel Mansour
DBDenise Bruedgam
Denise Bruedgam
UDUlrich Dischinger
Ulrich Dischinger
LKLydia Kürzinger
Lydia Kürzinger
CAChristian Adolf
Christian Adolf
DHDaniel Heinrich
Daniel Heinrich
Objective: To investigate the effects of simultaneous cortisol cosecretion (CCS) on body composition in computed tomography (CT)‐imaging and metabolic parameters in patients with primary aldosteronism (PA) with the objective of facilitating early detection.Design: Retrospective cohort study.Patients: Forty‐seven patients with PA and CCS confirmed by 1‐mg dexamethasone suppression test (DST) with a cutoff of ≥1.8 µg/dL were compared with PA patients with excluded CCS (non‐CCS, n = 47) matched by age and sex.Methods: Segmentation of the fat compartments and muscle area at the third lumbar region was performed on non‐contrast‐enhanced CT images with dedicated segmentation software. Additionally, liver, spleen, pancreas and muscle attenuation were compared between the two groups.Results: Mean cortisol after DST was 1.2 µg/dL (33.1 nmol/L) in the non‐CCS group and 3.2 µg/dL (88.3 nmol/L) in the CCS group with mild autonomous cortisol excess (MACE). No difference in total, visceral and subcutaneous fat volumes was observed between the CCS and non‐CCS group (p = .7, .6 and .8, respectively). However, a multivariable regression analysis revealed a significant correlation between total serum cholesterol and results of serum cortisol after 1‐mg DST (p = .026). Classification of the patients based on visible lesion on CT and PA‐lateralization via adrenal venous sampling also did not show any significant differences in body composition.Conclusion: MACE in PA patients does not translate into body composition changes on CT‐imaging. Therefore, early detection of concurrent CCS in PA is currently only attainable through biochemical tests. Further investigation of the long‐term clinical adverse effects of MACE in PA is necessary.

6 June 2023 in Clinical Nuclear Medicine
Verified
Journal Article
Closed access
NMNabeel Mansour
Nabeel Mansour
KRKasturi Rangan
Kasturi Rangan
RTReinhold Tiling
Reinhold Tiling
JRJohannes Rübenthaler
Johannes Rübenthaler
MFMatthias P. Fabritius
Matthias P. Fabritius
We present a rare case of a 74-year-old woman who underwent 68Ga-DOTATOC PET/CT imaging for a suspected neuroendocrine tumor (NET) in the pancreatic head. PET/CT showed a solitary high somatostatis receptor (SSTR)-expressing lesion in the pancreatic head. Fine-needle aspiration of this lesion revealed a metastasis from a clear cell renal cell carcinoma (ccRCC). The patient had undergone nephrectomy 16 years prior due to ccRCC of the right kidney. Our case demonstrates that metastases originating from RCC can have high SSTR expression and therefore might mimic well-differentiated neuroendocrine tumors in 68Ga-DOTATOC PET/CT.

12 December 2024 in Frontiers in Endocrinology
Verified
Journal Article
Open access
PDF file
NMNabeel Mansour
Nabeel Mansour
DBDenise Bruedgam
Denise Bruedgam
DHDaniel Heinrich
Daniel Heinrich
UDUlrich Dischinger
Ulrich Dischinger
NRNicole Reisch
Nicole Reisch
OCOsman Cal
Osman Cal
Objectives: Glucocorticoid cosecretion is more common in primary aldosteronism (PA) than previously thought. Chronic subtle cortisol excess in patients with mild autonomous cortisol secretion (MACS) negatively affects bone health. This study aimed to evaluate the impact of MACS on bone density and turnover markers in PA patients.Methods: Patients with PA and MACS (n = 50), confirmed by a 1-mg dexamethasone suppression test (DST) with a cortisol cutoff of ≥1.8 µg/dL without symptoms of overt Cushing, were compared to age- and sex-matched patients with PA without MACS (non-MACS, n = 50). Lumbar volumetric bone mineral density (vBMD) was extracted by a novel convolutional neural network (CNN)-based framework (SpineQ software v1.0) applied to routine CT data, incorporated into the diagnostic protocol for PA. Additionally, bone turnover markers—including osteocalcin, bone-specific alkaline phosphatase, N-terminal propeptide of type I collagen, and carboxy-terminal crosslinked telopeptide of type I collagen were evaluated between the groups.Results: Median cortisol after DST was 1.1 µg/dL (30.3 nmol/L) [IQR: 0.5 µg/dL (13.8 nmol/L)] in the non-MACS group and 2.5 µg/dL (69.0 nmol/L) [IQR: 1.4 µg/dL (38.5 nmol/L)] in the MACS group (p < 0.001). Patients with MACS had significantly lower vBMD values compared to the non-MACS group (106.4 mg/cm³ vs. 116.6 mg/cm³, p = 0.038). Cortisol after DST negatively correlated with vBMD (Spearman’s r=−0.33, p=0.00042). No significant differences in bone turnover markers were found, and classifications based on visible lesions on CT or PA-lateralization via adrenal venous sampling did not reveal any significant differences in these markers (p > 0.05 for all comparisons).Conclusion: Despite non-significant differences in bone turnover markers between patients with PA with or without MACS, CT scans revealed significantly reduced vBMD in PA and MACS patients, indicating compromised bone health and vBMD significantly negatively correlated with cortisol post DST. Thus, opportunistic evaluation of vBMD in routine CT screenings could aid in the early detection of bone alterations in MACS and help mitigate potential long-term adverse effects on bone health.

23 July 2025 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
NMNabeel Mansour
Nabeel Mansour
JJJulian Joram
Julian Joram
FGFreba Grawe
Freba Grawe
AHAnna Hinterberger
Anna Hinterberger
JRJohannes Rübenthaler
Johannes Rübenthaler
MFMatthias P. Fabritius
Matthias P. Fabritius
Purpose: Somatostatin receptor (SSTR)-targeted PET/CT provides valuable clinical insights beyond standard imaging in meningioma patients. Due to its excellent diagnostic capabilities and favorable logistics, the 18 F-labeled SSTR-targeting peptide SiTATE is increasingly in demand. We aimed to validate a recently proposed standard uptake value (SUV) threshold for accurate meningioma delineation in a clinically diverse patient cohort, including complex anatomical locations and lesions with prior surgical intervention. Methods: Consecutive patients with known or suspected meningioma who underwent [ 18 F]SiTATE PET/CT and contrast enhanced cerebral MRI were included. Lesions were semi-automatically segmented on PET images using an individualized minimal SUV (SUV min ) within a manually defined volume of interest. Correlative CT and MRI images were used to refine segmentations for each lesion, identifying the optimal lesion-specific SUV min to accurately capture the true volume of the meningioma. All lesions were additionally segmented using the recently proposed threshold of 4.0, and resulting volumes were compared. Results: 61 patients with 109 lesions were analyzed: 40 (37%) extraosseous, 32 (29%) partial trans-osseous, and 37 (34%) predominantly intraosseous. The median optimal SUV min for lesion delineation was 4.2. Osseous involvement did not significantly affect the median SUV min ( p = 0.1). Individualized SUV volumes showed excellent absolute agreement with those obtained using the fixed threshold of 4.0 (ICC[A,1] = 0.967; 95% CI: 0.952–0.977; p < 0.0001). However, 17 lesions (SUV max < 4.2) were not captured by the fixed threshold. Conclusion: The proposed SUV threshold of 4.0 showed promising results, supporting its suitability for clinical practice. Although limitations were evident, with 16% of lesions — primarily very small — showing reduced uptake and therefore not captured by this threshold, the study underscores its applicability in clinical practice.