OBJECTIVES: To evaluate the effectiveness of hydrogen peroxide (H2O2) in the form of mouthwash and nasal spray as an auxiliary treatment for coronavirus disease 2019 (COVID-19).METHODS: Forty hospitalized patients who tested positive for severe acute respiratory syndrome coronavirus 2 using a reverse-transcription polymerase chain reaction test were evaluated. They were randomly divided into an experimental group (n= 20; gargling with 1.0% H2O2 and nasal wash with 0.5% H2O2) or a control group (n= 20). The solutions were used for 7 days and the patients were monitored every 2 days, for a total of 8 days. At check-ups, patients were asked about their symptoms and possible adverse effects of the solutions. The presence and severity (mild, moderate, or severe) of symptoms were recorded. Data were compared using the Student test and the Fisher exact test (α= 0.05).RESULTS: There was no significant difference between the 2 groups in the length of hospital stay (p= 0.65). The most frequent symptom on day 0 was coughing (72.0% in the experimental group and 76.5% in the control group), which abated over time. There was no significant difference between the groups in the evaluated symptoms. Most (75.0%) of the patients in the experimental group presented a reduction in dyspnea between days 0 and 2. Few patients reported adverse effects from the use of the solutions.CONCLUSIONS: H2O2 as a mouthwash and nasal spray is safe to use. There is insufficient evidence to demonstrate that H2O2 is effective as an auxiliary treatment for hospitalized COVID-19 patients.
OBJECTIVES: This study evaluated the effectiveness of hydrogen peroxide (H2O2) as mouthwash and nasal spray on symptom relief in coronavirus disease 2019 (COVID-19) patients.METHODS: Patients positive for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), who were treated in a hospital or at home, and patients’ family members (not positive for SARS-CoV-2), were randomized into 2 groups: experimental (1% H2O2 for gargling, 0.5% H2O2 for nasal wash), and control. Patients gargled the solution 3 times a day, and applied the nasal spray twice a day, for a 7-day period. Family members received the same treatment as the treated COVID-19 patient. The researchers contacted patients every 2 days over an 8-day period. An average post-treatment interval of 8 days passed before testing family members.RESULTS: The most frequent symptoms on day 0 were cough, loss of taste, and hyposmia; there were no significant differences between groups, independent of the period. The symptom of dyspnea presented a significant difference between days 2 and 4 (p<0.05). Among family members, 86.0% had no antibodies, 2.3% had antibodies, and 11.6% had active infections (4 in the experimental group and 6 in the control group). The most frequent adverse effects in the H2O2 group were a burning throat and nose.CONCLUSIONS: H2O2 was not effective for the relief of COVID-19 symptoms and was associated with reports of transient adverse effects.
The design of custom abutments (CA) can affect the mechanical reliability of implant-supported restorations. The purpose of the study was to evaluate the influence of design parameters on the fatigue limit of CA and to compare optimized custom designs with the reference abutment (RA). A morse-tapered dental implant, an anatomical abutment, and a connector screw were digitalized using microcomputed tomography. A cone beam computed tomography scan was obtained from one of the authors to virtually place the implant-abutment assembly in the upper central incisor. Ten design parameters were selected according to the structural geometry of the RA and the implant planning. A reverse-engineered RA model was created in SOLIDWORKS and was modified considering a Taguchi orthogonal array to generate 36 CAs with ±20% dimensional variations. Finite element analysis was conducted in ABAQUS, and fatigue limits were estimated using Fe-safe. ANOVA (α = 0.1) identified the most influential parameters. Von Mises stress values ranged from 229 MPa to 302 MPa, and 94.4% of the CAs had a higher fatigue limit than the RA. Three parameters significantly affected the fatigue performance of the implant system. The design process of custom abutments includes critical design parameters that can be optimized for longer lifetimes of implant-abutment restorations.
To evaluate the influence of internal connection parameters on the fatigue limit of narrow-diameter dental implants using finite element analysis (FEA). A narrow-diameter dental implant (3.0 mm, Morse taper connection) and its corresponding abutment and screw were scanned using micro-computed tomography (micro-CT). High-resolution 3D models were reconstructed (Simpleware, Synopsis), and six geometric parameters defining the internal connection were extracted. A reference 3D assembly was built in SolidWorks, and systematic dimensional variations (±20%) of the six design parameters were introduced based on a Taguchi orthogonal array (DOE++, Reliasoft), resulting in 27 modified assemblies. Static FEA was performed in ABAQUS according to ISO 14,801:2016 geometry. Fatigue performance was estimated using Fe-safe software, and sensitivity analyses were conducted to identify the most influential parameters on the predicted fatigue limit. The reference model presented a fatigue limit of 193 N. Dimensional optimization based on FEA improved the fatigue limit up to 295 N, representing a 52.3% increase compared to the original design, with the cervical opening diameter (CID) showing a significant effect on fatigue performance. Systematic variation of internal connection geometry significantly affected the fatigue resistance of narrow-diameter implants. Identifying critical parameters enables the development of more durable and reliable implant-abutment assemblies, maximizing the treatment success in anatomically compromised sites. Optimizing the internal geometry of narrow-diameter implants can improve load distribution, minimize mechanical complications, and increase the longevity of implant-supported rehabilitations in areas with reduced bone volume.
This study aimed to evaluate the compressive and adhesive strengths of ceramic restorations (PICN and 5Y‐PSZ zirconia) cemented with one of three types of cements: conventional glass ionomer cement (GI), resin‐modified glass ionomer cement (RM‐GI), and self‐adhesive resin cement (R). Ceramic specimens (5Y‐PSZ, n = 72; PICN, n = 60) were prepared for testing after cementation onto glass fiber‐reinforced resin‐based composite tooth analogs. The 5Y‐PSZ specimens underwent tribochemical silica coating before cementation. Specimens intended for compressive strength evaluation were mechanically cycled (500,000 cycles) before testing. A microtensile bond strength test was used to evaluate adhesive strength, with specimens sectioned into microbars (1 mm2 cross‐section) and loaded until fracture. If pre‐test failures occurred, bond strength was assessed using microshear tests. PICN restorations showed significantly higher compressive strength than 5Y‐PSZ. For PICN, self‐adhesive resin cement yielded the highest compressive strength. For adhesive strength, PICN restorations cemented with self‐adhesive or RM‐GI cements outperformed GI. The 5Y‐PSZ+R combination showed the highest microshear bond strength, superior to 5Y‐PSZ+RM‐GI and 5Y‐PSZ+GI. Resin cements showed higher compressive and adhesive strengths for PICN than glass ionomer‐based cements. For 5Y‐PSZ, the cement type did not significantly affect compressive strength. Overall, PICN restorations outperformed 5Y‐PSZ in compressive and adhesive strengths.