Line-commutated rectifiers are often utilized in machine-converter systems and many energy conversion applications. Simulation of such power systems using detailed switching models of rectifiers is computationally expensive, and as an alternative for system-level studies, the so-called average-value modeling (AVM) techniques have become indispensable. The parametric AVM (PAVM) uses a computerized approach for establishing the key relationships between the averaged ac and dc variables. In this paper, a generalized PAVM (GPAVM) is proposed which extends several previously proposed models. The new GPAVM includes the ac harmonics in thyristor-controlled rectifier models considering their non-linear dependency on the line frequency. The new model is verified using detailed simulations and experimental results and is demonstrated to have better accuracy in a wider range of operating conditions and speeds/frequencies.
12 January 2023 in IEEE Transactions on Energy Conversion
Hall-sensor-controlled brushless dc (BLDC) motors are widely used in many electromechanical applications due to their simplicity and good torque-speed characteristics. The conventional commutation methods include the 120° and 180° switching logics that can be derived directly from the Hall sensor signals. The 120° switching method is the most common due to its natural approximation of the maximum torque per Ampere (MTPA) operation, while the 180° switching method offers a higher available phase voltage for the same dc voltage. Both methods are typically used with additional pulse-width modulation to control the motors from a fixed dc source. Recently, attention has been given to the operation of BLDC motors with conduction angles between 120° and 180° (e.g., 150°, 160°, etc.), where some benefits may be gained. This paper proposes a new methodology that continuously extends the operation from 120° to 180°, while maintaining the MTPA property. Simulations and experimental results based on a typical industrial BLDC motor demonstrate the proposed control methodology and its benefits over the conventional alternative methods.
7 November 2022 in IEEE Transactions on Energy Conversion
Average-value models (AVMs) of high-frequency switching voltage-source converters (VSCs) are indispensable for fast/efficient simulation of VSC-based power systems. However, in EMT/EMTP-type programs large simulation time-steps cannot be utilized with conventional non-iterative interfacings of AVMs due to numerical inaccuracy/instability as a result of a one-time-step interfacing delay. In this letter, a directly-interfaced AVM has been developed for the VSCs which eliminates the interfacing delay and allows large time-steps. This is achieved by formulating the AVM in the nodal form that is solved simultaneously with the overall network nodal equations. The new proposed model is demonstrated to outperform the existing AVMs of VSCs in terms of accuracy at fairly large time steps.
23 May 2022 in IEEE Transactions on Energy Conversion
AC–DC converters are widely used in many power-electronic-based systems. There is an increasing need to simulate such systems using larger time-steps in offline and/or real-time electromagnetic transient (EMT or EMTP) simulators. The so-called parametric average-value models (PAVMs) have been developed to allow larger time-steps and provide fast simulations. However, the application of PAVMs in nodal-analysis-based EMTP programs typically requires a one-time-step delay between the interfacing sources and the network solution (i.e., indirect interfacing), causing inaccuracy and numerical instability at medium-to-large time-steps. This paper presents a direct interfacing method for PAVMs of line-commutated rectifiers (LCRs). The proposed method linearizes the PAVM interfacing equations and incorporates the respective sub-matrices and history terms into the network nodal equations, which eliminates the need for a time-step delay. Simulation studies verify the effectiveness of the proposed method in EMTP-type solution wherein very good accuracy and numerical stability is achieved at fairly large time-steps, which has not been previously possible with conventional methods.
3 May 2018 in IEEE Transactions on Energy Conversion
Line-commutated rectifiers (LCRs) are extensively utilized in exciters of large electrical machines, ac-dc power systems of ships, vehicles, aircraft, and many other industrial applications. Efficient and accurate computer simulations are necessary to analyze various aspects of such systems under both normal and unbalanced/faulty operating conditions. The so-called parametric average-value modeling (PAVM) technique has been recently developed and shown to provide accurate and computationally efficient models of power-electronic converters for system-level simulations. In this paper, the PAVM methodology is extended to LCRs with internal faults. The new formulation considers the asymmetrical operation of rectifiers by including the ac-side characteristic (i.e., 5 th , 7 th , etc.) and non-characteristic (i.e., 2 nd , 3 rd , 4 th , etc.) harmonics in both positive and negative sequences as well as dc components that may be present on ac variables. The proposed PAVM is verified by experimental measurements and detailed model and is demonstrated to have excellent accuracy under various operating modes and fault configurations.
6 March 2024 in IEEE Transactions on Energy Conversion
Efficient and accurate simulation tools are crucial for studying the dynamics and stability of modern power systems with high penetration of voltage-source converters (VSCs). This paper proposes an admittance-based electromagnetic transient program (ABM-EMTP) approach for analyzing large-scale VSC-based energy conversion systems. Compared to the traditional EMTP approach with a detailed representation of all switches or the use of average-value models for the VSCs, the proposed approach applies impedance-based modeling to the VSC-based resources, which reduces the effective network to be simulated and the size of the overall nodal equation. An additional benefit is that the constructed admittances may be used for the small-signal stability analysis conducted within the EMTP environment. The benefits of the proposed approach over the conventional method that uses AVMs of VSCs are demonstrated on a VSC-based energy conversion system in the offline (PSCAD) and real-time (RTDS) transient simulations. It is verified that the proposed ABM-EMTP method enables high accuracy with larger simulation time steps, significantly improving the simulations’ overall computational performance. It is also shown that the small-signal stability of the system can be accurately assessed using the developed ABMs, including the frequency-coupling dynamics and oscillations.