27 August 2015 in IEEE Transactions on Energy Conversion
Brushless permanent magnet (BLPM) motor drives based on Hall sensors have received extensive attention in the literature and are widely used in many applications. However, most of the available and published controllers assume that the Hall signals are always available, which is not true if any of the sensors are faulted. In this paper, several fault-tolerant control schemes for BLPM motor drives are proposed. The methodology is based on fault diagnosis and its classification, and subsequent signal reconstruction. Simulation and experimental results demonstrate the effectiveness and advantages of the proposed fault-tolerant schemes in restoring the motor operation when failures occur in up to two Hall sensors. The proposed fault-tolerant schemes can be easily and flexibly realized for conventional drive systems, either by adding the code in the existing driver or by adding a simple auxiliary circuit between the Hall sensors and the driver.
2 March 2016 in IEEE Transactions on Energy Conversion
Brushless permanent magnet motor drives based on Hall sensors have received significant attention in recent years. In this area, the faults of Hall sensors become a new concern and several fault-tolerant control (FTC) methods have been proposed. However, most of the state-of-the-art FTC methods require some time to reconstruct the correct Hall sensor signals, which results in significant transient currents and speed dip during fault diagnostic process (FDP). In this paper, a new and improved FTC scheme based on FDP and vector-tracking observer is proposed. A method to identify the duration of FDP is proposed based on the analysis of acceleration estimation and the fault diagnosis results. During FDP, the method defaults to an open-loop observer control, which removes the undesirable current/torque transient. After that, the close-loop observer is re-enabled and the motor operation is restored. The proposed FTC is demonstrated in detailed simulations and experimentally on 120° brushless dc motor drives and sinusoidal PM motor drives. For both types of drives, a significant improvement is achieved in steady state and transient operation with faults of up to two Hall sensors, which has not been possible with available alternative FTC approaches (unless a sensorless control is used).
24 November 2014 in IEEE Transactions on Energy Conversion
Recently, the concepts of dynamic phasors and shifted-frequency analysis (SFA) have received renewed attention as a possible solution framework for the modeling of power system components and transients, as opposed to using instantaneous time-domain variables or conventional phasors. In this paper, a new voltage-behind-reactance (VBR) synchronous machine model based on SFA is presented. Using dynamic phasors, the proposed model permits the use of a much larger range of step sizes to efficiently simulate electromagnetic and electromechanical transients. Moreover, the proposed model has a constant-parameter (CP) stator interface, which is simple to implement and numerically more efficient compared with the prior state-of-the-art models with rotor-position-dependent stator inductance matrices. Rigorous transient case studies demonstrate that the new model requires significantly fewer time steps than the conventional time-domain models, and is more efficient than the previously established variable-parameter SFA model.
13 December 2016 in IEEE Transactions on Energy Conversion
Line-commutated rectifiers (LCRs) are widely used in various industrial applications, wherein they are also known to be a significant source of harmonics. The dynamic phasor (DP) modeling approaches have been well studied in the literature to simulate the dynamics of power systems and their components including harmonics. In this paper, the state-of-the-art analytical DP (ADP) models of LCRs, which relate the ac and dc subsystems through complicated switch functions, are first investigated. Then, a new parametric DP (PDP) model of LCRs is proposed, wherein the DP dynamics of rectifier/dc-link are represented using a set of explicit algebraic functions that are numerically established. Rigorous computer studies demonstrate that the proposed PDP methodology is capable of accurately predicting the steady-state and transient responses of LCR systems under a wide range of loading conditions, while providing significant computational advantages over the conventional detailed model and the established ADP models.
13 September 2017 in IEEE Transactions on Energy Conversion
Line-commutated rectifiers are often utilized in machine-converter systems and many energy conversion applications. Simulation of such power systems using detailed switching models of rectifiers is computationally expensive, and as an alternative for system-level studies, the so-called average-value modeling (AVM) techniques have become indispensable. The parametric AVM (PAVM) uses a computerized approach for establishing the key relationships between the averaged ac and dc variables. In this paper, a generalized PAVM (GPAVM) is proposed which extends several previously proposed models. The new GPAVM includes the ac harmonics in thyristor-controlled rectifier models considering their non-linear dependency on the line frequency. The new model is verified using detailed simulations and experimental results and is demonstrated to have better accuracy in a wider range of operating conditions and speeds/frequencies.
21 January 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Three-level T-type converter (3LT2C) possesses the advantages of simple structure and high efficiency, which makes it appealing especially in low- and medium-voltage applications. Dynamic average-value modeling (AVM) has become an effective methodology for small-signal analysis and large-signal transients of power electronic subsystems in power systems applications. In this paper, a dynamic AVM for the three-phase 3LT2C is presented for the first time. The proposed model is derived using the state-space average (SSA) approach, where the averaging process is implemented over each PWM switching period. The acand dc-side dynamics are represented by a fourth-order time-invariant system. The accuracy of the developed AVM is validated against the detailed switching model, while demonstrating its computational advantages. The new model is also verified using experimental tests on a prototype.