With the increase in subway travelers, the air quality of underground enclosed spaces at subway stations has attracted much more attention. The study of pollutants exposure assessment, especially fine particulate matter, is important in both pollutant control and metro station design. In this paper, combining pedestrian flow analysis (PFA) and computational fluid dynamics (CFD) simulations, a novel surrogate-assisted particulate matter exposure assessment method is proposed, in which PFA is used to analyze the spatial-temporal movement characteristics of pedestrians to simultaneously consider the location and value of the pedestrian particulate generation source and their exposure streamline to particulate matter; the CFD model is used to analyze the airflow field and particulate matter concentration field in detail. To comprehensively consider the differences in the spatial concentration distribution of particulate matter caused by the time-varying characteristics of the airflow organization state in subway stations, surrogate models reflecting the nonlinear relationship between simulated and measured data are trained to perform accurate pedestrian exposure calculations. The actual measurement data proves the validity of the simulation and calculation methods, and the difference between the calculated and experimental values of the exposure is only about 5%.
The non-uniform thermal distribution in the active neutral-point clamped (ANPC) topology causes significant thermal gradients during high-power operation, restricting its use in large-capacity power conversion systems like variable-speed pumped storage. This study introduces a novel hybrid fundamental frequency modulation strategy. Through a dynamic allocation mechanism based on a reference signal, this strategy alternates inner and outer power switches at the fundamental frequency, ensuring balanced switching frequency across devices. Consequently, it effectively mitigates the inherent loss imbalance in conventional ANPC topologies. Quantitative analysis using a power device loss model shows that, compared to conventional carrier phase-shift modulation, the proposed method reduces total system losses by 39.98% and improves the loss-balancing index by 18.27% over inner-switch fundamental frequency modulation. A multidimensional validation framework, including an MW-level hardware platform, numerical simulations, and test data, was established. The results confirm the proposed strategy’s effectiveness in improving power device thermal balance.
The electromagnetic vibration characteristics of doubly fed induction machines (DFIMs) employed in variable-speed pumped storage units, which must accommodate frequent power response and operational mode transitions, serve as critical indicators for assessing unit safety and stability. Nevertheless, there persists a significant research gap regarding generalized vibration analysis models and comprehensive investigations into their steady-state and dynamic vibration performance. To address this challenge, this study develops a universal analytical model for electromagnetic excitation forces in DFIMs using Maxwell’s stress tensor method, explicitly incorporating operational conditions such as rotor eccentricity and load imbalance. Using a 300 MW DFIM as a case study, we employ a hybrid numerical-analytical approach to examine the detrimental effects of harmonic currents generated by rotor-side converters. Furthermore, we systematically analyze how spatial harmonics induced by mechanical faults and temporal harmonics arising from electrical faults collectively influence the electromagnetic vibration behavior. Experimental validation conducted on a 10 MW DFIM prototype through vibration displacement measurements confirms the efficacy of the proposed analytical framework.