The non-uniform thermal distribution in the active neutral-point clamped (ANPC) topology causes significant thermal gradients during high-power operation, restricting its use in large-capacity power conversion systems like variable-speed pumped storage. This study introduces a novel hybrid fundamental frequency modulation strategy. Through a dynamic allocation mechanism based on a reference signal, this strategy alternates inner and outer power switches at the fundamental frequency, ensuring balanced switching frequency across devices. Consequently, it effectively mitigates the inherent loss imbalance in conventional ANPC topologies. Quantitative analysis using a power device loss model shows that, compared to conventional carrier phase-shift modulation, the proposed method reduces total system losses by 39.98% and improves the loss-balancing index by 18.27% over inner-switch fundamental frequency modulation. A multidimensional validation framework, including an MW-level hardware platform, numerical simulations, and test data, was established. The results confirm the proposed strategy’s effectiveness in improving power device thermal balance.
Model predictive control (MPC) has become an attractive solution for doubly fed induction motors (DFIMs) due to its fast dynamic response and multi-variable constraint handling capability. However, the performance of conventional MPC relies on the accuracy of the system model. To further enhance the control performance and adaptability, this paper proposes a fuzzy logic-based model predictive control (FL-MPC) strategy. The proposed method continuously monitors the current tracking errors and their rates of change, utilizing a fuzzy inference system to dynamically optimize the weight distribution within the predictive model. This enables the controller to autonomously adjust its behavior for optimal performance across a wide range of operating conditions. Both simulation and experimental results demonstrate that, compared to the conventional MPC, the proposed FL-MPC strategy achieves superior dynamic response.
Gravity storage has become an important development direction of physical energy storage technology due to its high energy conversion efficiency and low site selection difficulty. However, the existing gravity energy storage systems based on pure mechanical transmission still have shortcomings, such as low reliability and high operation and maintenance costs, which seriously limit their promotion. To overcome this obstacle, this paper proposes a linear-motor direct-drive gravity energy storage system (LMDD-GESS) with a simpler structure and higher energy conversion efficiency. The cableless flux-switching permanent magnet linear motor (SFPMLSM) is used to replace the traditional wire rope or chain transmission mechanism and fundamentally eliminates frictional losses. Firstly, in terms of the SFPMLSM, the thrust fluctuation is suppressed through the integrated design of the permanent magnet and armature winding on the mover side and the optimization of the end magnetic blocks. In terms of the system grid connection, the double-closed-loop PI control of the machine side and the three-level coordination strategy of the grid side are established, and the in-phase carrier PWM modulation and harmonic feedback compensation algorithm are used to improve the quality of grid connection. The speed curve optimization and multi-machine-switching scheme are designed to achieve smooth power output. The simulation results show that the proposed system significantly improves the operation efficiency and power output stability and provides a reliable gravity energy storage solution for the high proportion of new energy grids.
A hybrid scheme of flux linkage feedback (FLF) combined with the deep feed-forward (DFF)-genetic algorithm (GA) method to improve the synchronous stability of grid-following (GFL) converters is proposed in this paper. By subtracting three-phase flux linkages from three-phase voltage references generated by the GFL controller, the FLF and the parameter optimization based on DFF-GA are expected to improve the equivalent virtual damping in the dynamics of the angular speed of the phase-locked loop (PLL). The implementation of the proposed method will reduce the risk of synchronous instability of the converter with respect to the stability region. The virtual flux linkages can be calculated by the integration of the instantaneous voltage; thus, no additional measurement is required. The effectiveness of FLF has been verified by region of attraction, simulation, and experimental studies, which show that the system with the FLF scheme presents longer critical clearing time (CCT) than the traditional method and the PLL damping enhancement strategy. Moreover, the proposed scheme does not change the internal structure of the existing controller and is easy to implement on various GFL converters.
The modular multilevel matrix converter (M3C) can perform AC/AC conversion directly. However, M3C operation often requires a pre-charging process, which can be challenging due to the need for fast pre-charging with low inrush current. To address the issue, a closed-loop fast pre-charging strategy is proposed that utilizes an improved nearest level modulation (NLM) based on a quick-sorting algorithm for M3C. By improving the current limiting resistor and the number of Sub-Modules (SMs) inserted into the NLM, we achieve a reduction in inrush current when connected to the grid, and unlock the control algorithm, respectively. This paper presents the relationship between the current-limiting resistor, the pre-charging current, and the pre-charging time. Reactive power compensation is applied on the AC grid during the pre-charging process to ensure stability. Furthermore, the balanced control of capacitor voltage is employed to achieve synchronized and coordinated growth of capacitor voltages in SMs using a quick-sorting algorithm based on NLM. The simulation and experimental results demonstrate the effectiveness of this approach, making it suitable for M3C with a high number of SMs.
The electromagnetic vibration characteristics of doubly fed induction machines (DFIMs) employed in variable-speed pumped storage units, which must accommodate frequent power response and operational mode transitions, serve as critical indicators for assessing unit safety and stability. Nevertheless, there persists a significant research gap regarding generalized vibration analysis models and comprehensive investigations into their steady-state and dynamic vibration performance. To address this challenge, this study develops a universal analytical model for electromagnetic excitation forces in DFIMs using Maxwell’s stress tensor method, explicitly incorporating operational conditions such as rotor eccentricity and load imbalance. Using a 300 MW DFIM as a case study, we employ a hybrid numerical-analytical approach to examine the detrimental effects of harmonic currents generated by rotor-side converters. Furthermore, we systematically analyze how spatial harmonics induced by mechanical faults and temporal harmonics arising from electrical faults collectively influence the electromagnetic vibration behavior. Experimental validation conducted on a 10 MW DFIM prototype through vibration displacement measurements confirms the efficacy of the proposed analytical framework.