Celina Maria  DAMIAN

Dr. Celina Maria DAMIAN

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2016 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
AFAdriana Nicoleta Frone
Adriana Nicoleta Frone
DPDenis Mihaela Panaitescu
Denis Mihaela Panaitescu
Ioana NegruIoana Negru
Ioana Negru
CNCristian-Andi Nicolae
Cristian-Andi Nicolae
Zina VulugaZina Vuluga
Zina Vuluga
CDCelina Maria DAMIAN
Celina Maria DAMIAN

9 July 2013 in Discover Nano
Verified
Journal Article
Open access
PDF file
MRMatei D. Raicopol
Matei D. Raicopol
Alina Iuliana PrunaAlina Iuliana Pruna
Alina Iuliana Pruna
CDCelina Maria DAMIAN
Celina Maria DAMIAN
LPLuisa Pilan
Luisa Pilan
This article reports an amperometric glucose biosensor based on a new type of nanocomposite of polypyrrole (PPY) with p-phenyl sulfonate-functionalized single-walled carbon nanotubes (SWCNTs-PhSO3 −). An environmentally friendly functionalization procedure of the SWCNTs in the presence of substituted aniline and an oxidative species was adopted. The nanocomposite-modified electrode exhibited excellent electrocatalytic activities towards the reduction or oxidation of H2O2. This feature allowed us to use it as bioplatform on which glucose oxidase (GOx) was immobilized by entrapment in an electropolymerized PPY/SWCNTs-PhSO3 − film for the construction of the glucose biosensor. The amperometric detection of glucose was assayed by applying a constant electrode potential value necessary to oxidize or reduce the enzymatically produced H2O2 with minimal interference from the possible coexisting electroactive compounds. With the introduction of a thin film of Prussian blue (PB) at the substrate electrode surface, the PPY/GOx/SWCNTs-PhSO3 −/PB system shows synergy between the PB and functionalized SWCNTs which amplifies greatly the electrode sensitivity when operated at low potentials. The biosensor showed good analytical performances in terms of low detection (0.01 mM), high sensitivity (approximately 6 μA mM−1 cm−2), and wide linear range (0.02 to 6 mM). In addition, the effects of applied potential, the electroactive interference, and the stability of the biosensor were discussed. The facile procedure of immobilizing GOx used in the present work can promote the development of other oxidase-based biosensors which could have a practical application in clinical, food, and environmental analysis.

14 June 2018 in Coatings
Verified
Journal Article
Open access
PDF file
AFAdriana Nicoleta Frone
Adriana Nicoleta Frone
DPDenis Mihaela Panaitescu
Denis Mihaela Panaitescu
Ioana NegruIoana Negru
Ioana Negru
CNCristian-Andi Nicolae
Cristian-Andi Nicolae
ACAngela Casarica
Angela Casarica
PSPaul Octavian Stanescu
Paul Octavian Stanescu
Bacterial cellulose (BC) with increased hydrophobicity is required for several applications including packaging. Surface functionalization of BC may provide good resistance to moisture, increased barrier properties or improved compatibility to polymer matrices. For this purpose, chemical grafting of BC in mild, eco-friendly conditions was carried out using different agents. BC membranes were surface functionalized with vinyl-triethoxy silane (VS) or 3-aminopropyl triethoxysilane (APS), by acylation and acrylation. The efficiency of the surface treatments was highlighted by Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy, by contact angle measurements and by dynamic mechanical analysis. The morphological investigation by atomic force microscopy and scanning electron microscopy revealed an increased compactness for surface functionalized BC, which correlated well with the different increase of the contact angle. BC treated with APS and VS showed more than a twofold increase in contact angle value. Similarly, the crystallinity degree was reduced to 69.6% and 72.9% after APS and VS treatments as compared with 84.1% for untreated BC, confirming the grafting reaction and the decrease in hydrogen bonding. All the applied treatments delayed the degradation of BC. However, the highest increase in thermal stability was observed for silanes treated membranes. Effective, eco-friendly methods for improving the surface hydrophobicity of bacterial cellulose for food packaging were proposed in this study.

22 October 2020 in Polymers
Verified
Journal Article
Open access
PDF file
AFAdriana Nicoleta Frone
Adriana Nicoleta Frone
CNCristian-Andi Nicolae
Cristian-Andi Nicolae
MEMihaela Carmen Eremia
Mihaela Carmen Eremia
VTVlad-Constantin Tofan
Vlad-Constantin Tofan
MGMarius Ghiurea
Marius Ghiurea
DPDenis Mihaela Panaitescu
Denis Mihaela Panaitescu
The inherent brittleness of poly(3-hydroxybutyrate) (PHB) prevents its use as a substitute of petroleum-based polymers. Low molecular weight plasticizers, such as tributyl 2-acetyl citrate (TAC), cannot properly solve this issue. Herein, PHB films were obtained using a biosynthesized poly(3-hydroxyoctanoate) (PHO) and a commercially available TAC as toughening agents. The use of TAC strongly decreased the PHB thermal stability up to 200 °C due to the loss of low boiling point plasticizer, while minor weight loss was noticed at this temperature for the PHB-PHO blend. Both agents shifted the glass transition temperature of PHB to a lower temperature, the effect being more pronounced for TAC. The elongation at break of PHB increased by 700% after PHO addition and by only 185% in the case of TAC; this demonstrates an important toughening effect of the polymeric modifier. Migration of TAC to the upper surface of the films and no sign of migration in the case of PHO were highlighted by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) results. In vitro biocompatibility tests showed that all the PHB films are non-toxic towards L929 cells and have no proinflammatory immune response. The use of PHO as a toughening agent in PHB represents an attractive solution to its brittleness in the case of packaging and biomedical applications while conserving its biodegradability and biocompatibility.

27 September 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
EVEugenia Vasile
Eugenia Vasile
CZCatalin Zaharia
Catalin Zaharia
IRIonut Cristian Radu
Ionut Cristian Radu
Vasile-Adrian SurduVasile-Adrian Surdu
Vasile-Adrian Surdu
Bogdan Stefan VasileBogdan Stefan Vasile
Bogdan Stefan Vasile
EAEcaterina Andronescu
Ecaterina Andronescu
This paper reports the synthesis and complex characterization of nanocomposite hydrogels based on polyacrylamide and functionalized magnetite nanoparticles. Magnetic nanoparticles were functionalized with double bonds by 3-trimethoxysilyl propyl methacrylate. Nanocomposite hydrogels were prepared by radical polymerization of acrylamide monomer and double bond modified magnetite nanoparticles. XPS spectra for magnetite and modified magnetite were recorded to evaluate the covalent bonding of silane modifying agent. Swelling measurements in saline solution were performed to evaluate the behavior of these hydrogels having various compositions. Mechanical properties were evaluated by dynamic rheological analysis for elastic modulus and vibrating sample magnetometry was used to investigate the magnetic properties. Morphology, geometrical evaluation (size and shape) of nanostructural characteristics and the crystalline structure of the samples were investigated by SEM, HR-TEM and selected area electron diffraction (SAED). The nanocomposite hydrogels will be further tested for the soft tissue engineering field as repairing scaffolds, due to their mechanical and magnetization behavior that can stimulate tissue regeneration.

26 September 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
ECElena Alina Chiticaru
Elena Alina Chiticaru
LPLuisa Pilan
Luisa Pilan
CDCelina Maria DAMIAN
Celina Maria DAMIAN
EVEugeniu Vasile
Eugeniu Vasile
JBJorge Burns
Jorge Burns
Mariana IonitaMariana Ionita
Mariana Ionita
We have investigated the influence exerted by the concentration of graphene oxide (GO) dispersion as a modifier for screen printed carbon electrodes (SPCEs) on the fabrication of an electrochemical biosensor to detect DNA hybridization. A new pretreatment protocol for SPCEs, involving two successive steps in order to achieve a reproducible deposition of GO, is also proposed. Aqueous GO dispersions of different concentrations (0.05, 0.1, 0.15, and 0.2 mg/mL) were first drop-cast on the SPCE substrates and then electrochemically reduced. The electrochemical properties of the modified electrodes were investigated after each modification step by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), while physicochemical characterization was performed by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and Raman spectroscopy. Finally, the sensing platform was obtained by the simple adsorption of the single-stranded DNA probe onto the electrochemically reduced GO (RGO)-modified SPCEs under optimized conditions. The hybridization was achieved by incubating the functionalized SPCEs with complementary DNA target and detected by measuring the change in the electrochemical response of [Fe(CN)6]3–/4– redox reporter in CV and EIS measurements induced by the release of the newly formed double-stranded DNA from the electrode surface. Our results showed that a higher GO concentration generated a more sensitive response towards DNA detection.