Luisa Pilan

Prof. Luisa Pilan

University Politehnica of Bucharest, 7 Gheorghe Polizu, 011061 Bucharest, Romania
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2014 in Composites Part B: Engineering
Verified
Journal Article
Closed access
MIMariana Ionita
Mariana Ionita
Andreea Madalina PandeleAndreea Madalina Pandele
Andreea Madalina Pandele
LCLivia Crica
Livia Crica
LPLuisa Pilan
Luisa Pilan

9 July 2013 in Discover Nano
Verified
Journal Article
Open access
PDF file
MRMatei D. Raicopol
Matei D. Raicopol
Alina Iuliana PrunaAlina Iuliana Pruna
Alina Iuliana Pruna
CDCelina Maria DAMIAN
Celina Maria DAMIAN
LPLuisa Pilan
Luisa Pilan
This article reports an amperometric glucose biosensor based on a new type of nanocomposite of polypyrrole (PPY) with p-phenyl sulfonate-functionalized single-walled carbon nanotubes (SWCNTs-PhSO3 −). An environmentally friendly functionalization procedure of the SWCNTs in the presence of substituted aniline and an oxidative species was adopted. The nanocomposite-modified electrode exhibited excellent electrocatalytic activities towards the reduction or oxidation of H2O2. This feature allowed us to use it as bioplatform on which glucose oxidase (GOx) was immobilized by entrapment in an electropolymerized PPY/SWCNTs-PhSO3 − film for the construction of the glucose biosensor. The amperometric detection of glucose was assayed by applying a constant electrode potential value necessary to oxidize or reduce the enzymatically produced H2O2 with minimal interference from the possible coexisting electroactive compounds. With the introduction of a thin film of Prussian blue (PB) at the substrate electrode surface, the PPY/GOx/SWCNTs-PhSO3 −/PB system shows synergy between the PB and functionalized SWCNTs which amplifies greatly the electrode sensitivity when operated at low potentials. The biosensor showed good analytical performances in terms of low detection (0.01 mM), high sensitivity (approximately 6 μA mM−1 cm−2), and wide linear range (0.02 to 6 mM). In addition, the effects of applied potential, the electroactive interference, and the stability of the biosensor were discussed. The facile procedure of immobilizing GOx used in the present work can promote the development of other oxidase-based biosensors which could have a practical application in clinical, food, and environmental analysis.

1 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
AOAndra Mihaela Onaș
Andra Mihaela Onaș
CDConstanţa Dascălu
Constanţa Dascălu
MRMatei D. Raicopol
Matei D. Raicopol
LPLuisa Pilan
Luisa Pilan
Nucleic-acid aptamers consisting in single-stranded DNA oligonucleotides emerged as very promising biorecognition elements for electrochemical biosensors applied in various fields such as medicine, environmental, and food safety. Despite their outstanding features, such as high-binding affinity for a broad range of targets, high stability, low cost and ease of modification, numerous challenges had to be overcome from the aptamer selection process on the design of functioning biosensing devices. Moreover, in the case of small molecules such as metabolites, toxins, drugs, etc., obtaining efficient binding aptamer sequences proved a challenging task given their small molecular surface and limited interactions between their functional groups and aptamer sequences. Thus, establishing consistent evaluation standards for aptamer affinity is crucial for the success of these aptamers in biosensing applications. In this context, this article will give an overview on the thermodynamic and structural aspects of the aptamer-target interaction, its specificity and selectivity, and will also highlight the current methods employed for determining the aptamer-binding affinity and the structural characterization of the aptamer-target complex. The critical aspects regarding the generation of aptamer-modified electrodes suitable for electrochemical sensing, such as appropriate bioreceptor immobilization strategy and experimental conditions which facilitate a convenient anchoring and stability of the aptamer, are also discussed. The review also summarizes some effective small molecule aptasensing platforms from the recent literature.

3 September 2014 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
MRMatei D. Raicopol
Matei D. Raicopol
CACorina Andronescu
Corina Andronescu
RARuxandra Atasiei
Ruxandra Atasiei
AHAnamaria Hanganu
Anamaria Hanganu
LPLuisa Pilan
Luisa Pilan

26 September 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
ECElena Alina Chiticaru
Elena Alina Chiticaru
LPLuisa Pilan
Luisa Pilan
CDCelina Maria DAMIAN
Celina Maria DAMIAN
EVEugeniu Vasile
Eugeniu Vasile
JBJorge Burns
Jorge Burns
Mariana IonitaMariana Ionita
Mariana Ionita
We have investigated the influence exerted by the concentration of graphene oxide (GO) dispersion as a modifier for screen printed carbon electrodes (SPCEs) on the fabrication of an electrochemical biosensor to detect DNA hybridization. A new pretreatment protocol for SPCEs, involving two successive steps in order to achieve a reproducible deposition of GO, is also proposed. Aqueous GO dispersions of different concentrations (0.05, 0.1, 0.15, and 0.2 mg/mL) were first drop-cast on the SPCE substrates and then electrochemically reduced. The electrochemical properties of the modified electrodes were investigated after each modification step by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), while physicochemical characterization was performed by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and Raman spectroscopy. Finally, the sensing platform was obtained by the simple adsorption of the single-stranded DNA probe onto the electrochemically reduced GO (RGO)-modified SPCEs under optimized conditions. The hybridization was achieved by incubating the functionalized SPCEs with complementary DNA target and detected by measuring the change in the electrochemical response of [Fe(CN)6]3–/4– redox reporter in CV and EIS measurements induced by the release of the newly formed double-stranded DNA from the electrode surface. Our results showed that a higher GO concentration generated a more sensitive response towards DNA detection.

1 December 2012 in Composites Part B: Engineering
Verified
Journal Article
Closed access
Alina Iuliana PrunaAlina Iuliana Pruna
Alina Iuliana Pruna
LPLuisa Pilan
Luisa Pilan