Irene Martinez-Alberquilla

Dr. Irene Martinez-Alberquilla

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2021 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
MRMariano Royo
Mariano Royo
ÁJÁngel Jiménez
Ángel Jiménez
IMIrene Martinez-Alberquilla
Irene Martinez-Alberquilla
JAJosé F. Alfonso
José F. Alfonso
To analyse long-term efficacy, safety, visual and refractive stability and physiological changes of Artiflex Myopia and Toric phakic intraocular lenses (pIOL) separately throughout an 8-year follow-up. Retrospective cohort study. A total of 67 eyes of 37 patients underwent Artiflex Myopia (47 eyes) or Artiflex Toric (20 eyes) implantation for correcting myopia and/or astigmatism. Follow-up evaluations were performed 1, 3, 5 and 8 years after surgery. Preoperative and postoperative data included corrected (CDVA) and uncorrected distance visual acuity (UDVA), manifest refraction, endothelial cell density (ECD) and intraocular pressure (IOP) assessments. Efficacy and safety indexes were analysed. The vectorial analysis was performed using the Thibos method. Mean CDVA and UDVA of both pIOLs significantly improved from preoperative to 1 year after implantation, and then it remained stable over the 8-year follow-up. The efficacy and safety indexes after 8 years were 0.94 ± 0.16 and 1.07 ± 0.18 for Artiflex Myopia and 1.00 ± 0.11 and 1.10 ± 0.15 for Artiflex Toric, respectively. The spherical equivalent (SE) significantly improved after surgery. J0, J45 and SE refractive components showed no changes between postoperative visits. A total ECD loss of 4.8% (p < 0.001) and 10.4% (p = 0.005) was found after 8 years for Artiflex Myopia and Toric, respectively. Artiflex Myopia and Toric pIOLs are a safe, efficient and predictable option for the correction of myopia and/or astigmatism. The vectorial analysis showed excellent rotation stability for the toric version.

11 March 2021 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
JRJavier Ruiz-Alcocer
Javier Ruiz-Alcocer
IMIrene Martinez-Alberquilla
Irene Martinez-Alberquilla
ALAmalia Lorente-Velázquez
Amalia Lorente-Velázquez
JAJosé F. Alfonso
José F. Alfonso
DCDavid Madrid Costa
David Madrid Costa
Purpose: To objectively analyze the optical quality of the FineVision Toric intraocular lens (IOL) with two cylinder powers when different combinations of rotations and residual refractive errors are induced. Methods: This study assessed the FineVision Toric IOL with two different cylinder powers: 1.5 and 3.0 diopters (D). Three different rotation positions were considered: centered, 5° and 10° rotated. An optical bench (PMTF) was used for optical analysis. The optical quality of the IOLs was calculated by the modulation transfer function (MTF) at five different focal points (0.0, 0.25, 0.50, 0.75, and 1.00 D). Results: The MTF averaged value of the reference situation was 38.58 and 37.74 for 1.5 and 3.0 D of cylinder, respectively. For the 1.5 D cylinder, the combination of 5° of rotation with a defocus of 0.25, 0.50, 0.75, and 1.0 D induced a decrease on the MTF of 12.39, 19.94, 23.43, 24.23 units, respectively. When induced rotation was 10°, the MTF decrease was 17.26, 23.40, 24.33, 24.48 units, respectively. For the 3.0 D cylinder, the combination of 5° with 0.25, 0.50, 0.75, and 1.0 D of defocus, induced a decrease on the MTF of 12.51, 18.97, 22.36, 22.48 units, respectively. When induced rotation was 10°, the MTF decrease was: 18.42, 21.57, 23.08, and 23.61 units, respectively. Conclusion: For both FineVision Toric IOLs there is a certain optical tolerance to rotations up to 5° or residual refractive errors up to 0.25 D. Situations over these limits and their combination would affect the visual quality of patients implanted with these trifocal toric IOLs.

9 July 2019 in Journal of Ophthalmology
Verified
Journal Article
Open access
MGMaría García-Montero
María García-Montero
Laura Rico-del-ViejoLaura Rico-del-Viejo
Laura Rico-del-Viejo
IMIrene Martinez-Alberquilla
Irene Martinez-Alberquilla
JHJosé Luis Hernández-Verdejo
José Luis Hernández-Verdejo
ALAmalia Lorente-Velázquez
Amalia Lorente-Velázquez
DCDavid Madrid Costa
David Madrid Costa
Objective. The aim of this study was to investigate tear film optical quality dynamics for four types of silicone hydrogel contact lenses (SHCLs) for daily wear over a 15-day period and for different blink rate (BR) patterns. Methods. A prospective randomized, double-blind, cross-over pilot study including four SHCLs (A: lotrafilcon B (Air Optix plus HydraGlyde, Alcon Laboratories); B: samfilcon A (Ultra, Bausch & Lomb); C: comfilcon A (Biofinity, CooperVision); and D: filcom V3 (Blu:gen, Mark’Ennovy)). Serial measurements of Objective Scatter Index (OSI) using the HD Analyzer (Visiometrics S.L., Terrassa, Spain) were taken at different blinking patterns: blinking every 2.5 seconds (high BRs) and every 9 seconds (low BRs). They were performed during the first visit before CL insertion (baseline), after 20 minutes of CL wear (Day 1), and during the last visit after 8 hours of CL wear on day 15 of use (Day 15). Results. Normal young healthy subjects were recruited and fitted with the four lenses. For low BRs, the mean OSI value increased over time for all CLs and the slope of the curve also increased for all CLs, except for CL D. However, for high BRs, the mean OSI value increased only for CLs B and C and the slope of the curve did not change over time for any of them. Conclusions. These results suggest that the tear film optical quality dynamics after wearing SCHLs for 15 days seems to undergo a slight deterioration only for lowest BR.

27 August 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
AGAntonio Manuel Garrido-Hermosilla
Antonio Manuel Garrido-Hermosilla
IMIrene Martinez-Alberquilla
Irene Martinez-Alberquilla
MDMaría Concepción Díaz-Ruiz
María Concepción Díaz-Ruiz
RCRaquel Monge Carmona
Raquel Monge Carmona
MMMariola Méndez-Muros
Mariola Méndez-Muros
EREnrique Rodríguez-De-La-Rúa-Franch
Enrique Rodríguez-De-La-Rúa-Franch
Objectives: To assess the overall mental health of enucleated or eviscerated patients after high-density porous polyethylene OCULFIT implantation and external prosthesis over a 1-year follow-up. Methods: Patients with an indication of enucleation or evisceration with OCULFIT implantation were included in a prospective study. The patients completed four questionnaires regarding mental health at three different visits (baseline, 3–6 months, and 9–12 months post-surgery). The questionnaires used were the following: SF-12 for multidimensional health-related quality of life (scale 0–100); Rosemberg self-esteem scale (scale 0–40); Patients Health Questionnaire-4 (PHQ-4) (scale 0–6); and a Lifetime Major Depression and Anhedonia questionnaire (categorised in groups with/without symptoms). Results: A total of 33 patients (16 enucleations and 17 eviscerations) were included in the study. The physical domain of the SF-12 questionnaire did not change between visits, but the mental domain significantly improved from the baseline to the last visit (41.71 ± 12.72 vs. 46.80 ± 10.68, p = 0.04). The number of patients with high, moderate, and low self-esteem (Rosemberg scale) was similar between the baseline and the last visit. The depression and anxiety scores of the PHQ-4 were not significantly different among visits. The number of patients with no symptoms (depression or anhedonia) improved from the baseline (42.2%) throughout the follow-up (66.7% at the last visit). Conclusions: OCULFIT orbital implant and external prosthesis placement maintained and/or improved the quality of life related to mental health in eviscerated and enucleated eyes. The number of patients with no symptoms improved from the baseline throughout the follow-up. The patients’ self-esteem was already high before implantation and remained stable over the follow-up.

2 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Laura Rico-del-ViejoLaura Rico-del-Viejo
Laura Rico-del-Viejo
CLClara Llorens-Quintana
Clara Llorens-Quintana
IMIrene Martinez-Alberquilla
Irene Martinez-Alberquilla
DCDavid Madrid Costa
David Madrid Costa
MGMaría García-Montero
María García-Montero
Infrared (IR) thermography is a tool to non-invasively assess the tear film temperature. The aim was to analyze ocular surface temperature (OST) variations in dry eye disease (DED) and control eyes under natural non-controlled blinking conditions. Imaging was performed with a thermal camera (FLIR Systems Inc.) at 30 Hz framerate in 79 participants (39 DED (62.5% women, average age 48 ± 20 years) and 40 control (46.2 % women, average age 38 ± 13 years)) using non-contact IR thermography camera. Data acquisitions were performed in natural blinking conditions for 40 s. IR images were analyzed using a custom algorithm that calculates the OST indexes: mean OST, OST at the start and at the end, minimum and maximum OST, and tear evaporation rate (TER). No significant differences were found between groups in any thermal parameter analyzed (paired comparisons t-test, p > 0.05). In conclusion, the findings of this study did not reveal significant differences between DED and control eyes under natural non-controlled blinking conditions. However, the presence of clinical signs in the control group may affect the results, highlighting the role of DED diagnosis criteria.

27 November 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
AGAntonio Manuel Garrido-Hermosilla
Antonio Manuel Garrido-Hermosilla
IMIrene Martinez-Alberquilla
Irene Martinez-Alberquilla
MDMaría Concepción Díaz-Ruiz
María Concepción Díaz-Ruiz
RCRaquel Monge Carmona
Raquel Monge Carmona
MMMariola Méndez-Muros
Mariola Méndez-Muros
EREnrique Rodríguez-De-La-Rúa-Franch
Enrique Rodríguez-De-La-Rúa-Franch
OBJECTIVES: To describe our experience with a new high-density porous polyethylene orbital implant post-enucleation and evisceration and comment on their performance and safety. METHODS: Patients with an indication of enucleation or evisceration with orbital implantation were included in a prospective study. All patients were implanted with OCULFIT orbital implants (AJL Ophthalmic S.A.) and followed up over 12 months. Anatomical and functional parameters, motility, and aesthetic appearance were evaluated. Patient satisfaction on a scale of 0 (very bad) to 5 (excellent), complications and success rates were reported. RESULTS: Overall, 16 enucleated and 17 eviscerated eyes were analyzed. Orbital implant motility was good for 93.8% and 100% of enucleated and eviscerated patients, respectively. No shortened fornixes were found after external prosthesis placement, and palpebral fissure, orbital volume, and lower eyelid laxity were symmetric with the contralateral eye for the vast majority. The aesthetic appearance was good for 87.5% and 100% of enucleated and eviscerated patients at the last visit with no differences between groups. Excellent satisfaction was reported for 100% and 94.1% of enucleated and eviscerated patients. Anatomical and functional success rates were 78.8% and 81.8%, respectively. No exposure, infection or complications related to surgery were reported during the follow-up. CONCLUSIONS: After 1 year of follow-up, OCULFIT orbital implants provide excellent patient satisfaction and performance in terms of motility and symmetry with the contralateral eye after external prosthesis placement with no complications related to the surgical procedure. No differences between enucleated and eviscerated eyes were found, and aesthetic results were remarkable for both groups. Conclusions should be interpreted with caution due to the small sample size.